It is advisable to wear ear defenders when removing the siren from the wall as 
the tamper alarm will sound when activated. Another person will be needed to 
disarm the siren from the keypad immediately. 

 
 

1. With the siren removed from the wall, remove its rear cover. 
 
 

It is also advisable to wear ear defenders at this stage during the learning 
process also as the siren will sound 

 

 

2. Press the LEARN button once on the siren to enter learn mode. The red learn LED 
will be lit on the pcb for approximately 30 seconds. 
 

Note that if the sensor is activated when picked up, then wait for the green LED to turn off first 
before pressing the LEARN button on it 

 
3. Press the LEARN button once on the pcb of the door/window contact sensor. Its 
LED will flash green rapidly and the siren should produce 3 beeps to indicate 
successfully linked. 
 
 

Note: If no learn signal is received by the siren within approximately 30 seconds, the learn 
LED on the siren will turn off and the siren will exit learn mode automatically. 

 
 
4. Wait approximately 30 seconds for the siren to exit learn mode or press the 
LEARN button once on the siren to exit learn mode manually. 
 
5. Refit the back cover and re-install the siren again on the wall. Note that if the 
tamper switch is activated again, another person may be required to disarm it from 
the keypad by entering the 4 digit password and the DISARM key. 
 
 

How to know if the siren has too many devices linked to it 

If during the learning process the siren produces 4 beeps then this indicates it has 10 
devices already connected to it. 

 
 

INSTALLING THE DOOR/WINDOW CONTACTS  

 
 

1. Using the supplied fixings or double sided tape pad, mount the back casing of the 
sensor on the door/window frame and the magnet part on the door/window using the 
double sided tape pad supplied as shown on the next page. Only install the unit in 
dry interior locations. 
 
Note: If using the screws provided, you may need to remove the batteries before 
installing the back casing on the door/window frame and then insert them again 
afterwards

 

 
 

Содержание WHA3

Страница 1: ...ine type z The maximum number of sensors your system can take is 10 z If your alarm system is already installed then another person will be needed to disarm the siren from the keypad immediately when...

Страница 2: ...ot re assemble the front casing at this stage as you still need to link the sensor to the external siren The replacement batteries should be the equivalent alkaline type LINKING THE SENSOR TO THE EXTE...

Страница 3: ...e learn LED on the siren will turn off and the siren will exit learn mode automatically 4 Wait approximately 30 seconds for the siren to exit learn mode or press the LEARN button once on the siren to...

Страница 4: ...as been triggered for approximately 5 minutes When a door window contact sensor is in power save mode it will transmit a signal when it detects an open action once Within the next 5 minutes even it ha...

Страница 5: ...tact is left open then the unit will not operate JP3 jumper Jumper removed Wired sensor enabled Jumper installed Wired sensor disabled factory default Note Jumpers Z1 and Z2 are not used with your sys...

Страница 6: ...ggered and its blue LEDs will flash accordingly 5 Disarm your system from the keypad LOW BATTERY WARNING A red LED lighting up instead of green on the sensor indicates low batteries The typical batter...

Страница 7: ...e guarantee states Novar ED S entire liability It does not extent to cover consequential loss or damage or installation costs arising from the defective product This guarantee does not in any way affe...

Отзывы: