Each item listed in Table 1-1 is described below.
v40 Laser – for cutting, welding, drilling, and marking a wide variety of products and materials.
Quick Start Plug (except SAB models) – connects to ’s User I/O connector. Jumpers are built into the
plug to enable ’s shutter and remote interlock circuits for initial start-up and testing.
Cooling Tubing (water-cooled only) – carries cooling water from the chiller to the laser and back. This
black polyethylene tubing is 1/2" O.D. by 30 feet and must be cut to length.
Mounting Bolts – 1/4–20
×
5/8" bolts fasten to your mounting surface.
v40 Operator’s Manual – provides setup, operation, and maintenance information for your v40 laser.
Spare Fuse (not shown) – fast blow 25 A fuse protects ’s internal circuitry.
Final Test Report (not shown) – contains data collected during the laser’s final pre-shipment test.
Mounting
The Mounting section includes subsections:
•
Fastening from above
•
Fastening from below
v40’s base plate is designed so that the laser is easily mounted to either vertical or horizontal surfaces
using only three fasteners. Three ball bearing “feet” pressed into ’s base plate eliminate any possible
distortion of the laser tube caused by variations in the flatness of the surface on which the laser is
mounted. Refer to the v40 package outline drawings in the Technical Reference chapter for mounting
locations and dimensions. Read through the mounting sections below to determine which set of
mounting holes are required for your application. When mounting v40 lasers, you can choose to fasten
from above, into your mounting surface, or from below, into v40’s base plate.
Important Note: To allow proper airflow, air- or fan-cooled units must have at least 2.25" (57.2
mm) of unobstructed clearance between the outside edge of the cooling fan and any enclosure or
surface.
Caution: Possible Equipment Damage
NOVANTA does not recommend mounting lasers in a vertical “head-down” or “tail-down” orientation.
If you must mount your laser in this manner, please contact the factory for limitations as vertical
orientation increases the risk of damage to the laser’s output optic.
Содержание v40
Страница 1: ...ENGINEERED BY SYNRAD v40 Laser User Manual...
Страница 32: ...V40 LABEL LOCATIONS PAGE 32 V40 label locations Figure 2 1 V40 Hazard label locations...
Страница 38: ...EUROPEAN UNION EU REQUIREMENTS ROHS COMPLIANCE PAGE 38 Figure 2 2 Declaration Document...
Страница 56: ...USER I O CONNECTION SUMMARY PAGE 56 Table 4 3 User I O pin descriptions continued...
Страница 61: ...INPUT OUTPUT SIGNALS PAGE 61 Figure 4 8 Input equivalent schematic Table 4 4 Input circuit specifications...
Страница 72: ...V40 GENERAL SPECIFICATIONS PAGE 72 v40 general specifications Table 4 7 v40 general specifications...
Страница 73: ...V40 GENERAL SPECIFICATIONS PAGE 73 Table 4 7 v40 general specifications continued...
Страница 95: ...BEAM DELIVERY OPTICS PAGE 95 This page is left blank intentionally...
Страница 103: ...INDEX PAGE 1 This page is intentionally left blank...