DUTY CYCLE/PULSE WIDTH LIMIT FAULT
PAGE
|
96
Symptom:
•
The p400 is connected to a network; however, the p400 web interface does not open or locks up
while receiving data from the laser.
Possible Causes:
•
The p400 laser was connected to the network using a crossover cable.
A straight-through cable is required if connecting an p400 to a network via a network router, switch, or
hub.
•
Java script is not enabled in the web browser.
Locate your browser’s Internet Options menu and configure it to enable Java script. As shown in Figure
below, the Java feature is located on the Internet Options dialog’s Advanced tab (under Tools/Internet
Options). The dialog boxes in your particular browser may appear differently.
Figure 5-2 Enable Java script in browser.
•
Multiple p400’s is connected to the same network with identical IP addresses.
Make sure only one p400 laser is connected to the network at a time or, if multiple p400’s is connected,
be sure they have distinct IP addresses to prevent IP addressing conflicts.
•
The laser’s IP address is not recognized as an authorized site on your local intranet network or a
trusted site on the Internet.
Add the laser’s IP address to the list of authorized and/or trusted websites. In your browser, locate the
Internet Options dialog’s Security tab. The dialog boxes in your particular browser may appear
differently.
Содержание p400 OEM Series
Страница 1: ...ENGINEERED BY SYNRAD p400 OEM Series User Manual...
Страница 16: ...NOMENCLATURE CONTINUED PAGE 16 Nomenclature continued Figure 1 2 Anatomy of a model number...
Страница 22: ...P400 LABEL LOCATIONS PAGE 22 p400 label locations Figure 2 1 P400 hazard label locations...
Страница 28: ...EUROPEAN UNION EU REQUIREMENTS ROHS COMPLIANCE PAGE 28 Figure 2 2 EU Compliance mark...
Страница 45: ...CONTROL SIGNALS PAGE 45 Figure 4 15 Representative output energy profile 20 duty cycle 100 kHz 5 0 s timebase...
Страница 51: ...USER I O CONNECTION SUMMARY PAGE 51...
Страница 77: ...P400 SPECIFICATIONS PAGE 77 P400 Specifications Table 4 6 P400 general specifications...
Страница 78: ...P400 SPECIFICATIONS PAGE 78 Table 4 6 P400 general specifications continued...
Страница 79: ...P400 FLOW VS PRESSURE CURVE PAGE 79 P400 Flow Vs Pressure curve Figure 4 45 P400 pressure drop curve...
Страница 80: ...P400 OUTLINE AND MOUNTING DRAWINGS PAGE 80 P400 Outline and Mounting Drawings...
Страница 82: ...P400 OUTLINE AND MOUNTING DRAWINGS PAGE 82 Figure 4 48 P400 packaging instructions...
Страница 89: ...OPERATIONAL FLOWCHART PAGE 89 Operational flowchart Figure 5 1 p400 operational flowchart...
Страница 90: ...STATUS LED S PAGE 90 Status LED s Table 5 2 p400 Input Output LED Status Signals...
Страница 100: ...DUTY CYCLE PULSE WIDTH LIMIT FAULT PAGE 100 This page is left blank intentionally...