![Novanta MOVIA Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/novanta/movia/movia_user-manual_1710876017.webp)
3 Installation
3.3 Installation Instructions
MOVIA, 2-Axis Scan Head – User Manual, 1040–0004 Rev. 03
14
3.3.4
ELECTRICAL – POWER SUPPLY REQUIREMENTS
The maximum root mean square (rms) current required is approximately 3 amps,
however peak current demands may approach 10 amps on certain models.
MOVIA scan heads are tuned for ±15 V.
IMPORTANT
Higher voltage than specified
may damage the servo.
•
Use the correct voltage for the scan head.
3.3.5
APPLY POWER TO THE SCAN HEAD
Before powering on the overall system, confirm that you have the system
controller (or ScanMaster Controller) configured correctly to work with your laser.
For the ScanMaster Controller (SMC) refer to the SMC Quick Start Guide. Once
you’ve configured the controller to work with your laser and verified the function,
you can power the scan head on.
Perform Alignment of the Laser to the Scan Head To reduce the risk of injury,
please observe the laser safety guidelines in this section.
DANGER
Laser radiation
can cause severe retinal and corneal burns, burns on the skin, and may pose a
fire risk.
•
Never stare into the laser’s beam, place any parts of your body in the beam
path, or expose yourself to reflections of beams.