SAMPLE OUTPUT CIRCUITS
PAGE
|
43
Sample output circuits
Figures below illustrate how to connect the laser’s Remote Ready LED Output to a Programmable Logic
Controller (PLC) DC input module using current sourcing, current sinking, and resistive pull-up methods.
Important Note: You can use these same circuits to monitor the laser’s Remote Lase LED Output
(DB-9, Pin 8); however, the Remote Lase LED Output is not a steady state (on/off) output. It is a
Pulse Width Modulated (PWM) signal based on the PWM input signal to the laser.
Figure 4-9 Remote Ready output to PLC input (PLC sourcing).
The following figure illustrates how to connect the Fault Shutdown Output signal to a PLC. The Fault
Shutdown Output function signals a laser shutdown due to an under/over voltage condition, an over
temperature condition, or failure of internal circuitry.
Figure 4-10 Fault Shutdown Output to PLC input.