Safety Warnings, Dangers, Cautions and Instructions 

 

DANGER!  Welding and cutting operations pose serious inhalation hazards. Some of these 
hazards are immediate while others are cumulative in their effect.  Do not  weld in enclosed 
spaces or in areas without adequate ventilation.  Fumes and gases released in the welding 
and cutting operations can be toxic.  Use fans or respiration equipment to insure adequate 
ventilation if you are welding in a shop or garage area.  Do not weld on galvanized metal 
under any circumstance.  You may develop metal fume fever. Symptoms are similar to lu

-

like symptoms.  Seek medical advice and treatment if  you are exposed to galvanized weld-
ing fumes. 

 

If you experience any eye burning, nose or throat irritation while welding, these are signs 
that you need more ventilation. 

 

 If you feel these symptoms:

 

• 

Stop work immediately and relocate work area with better ventilation.

 

• 

Wash and clean your face  and hands.

 

• 

Stop work completely and seek medical help if irritation persists

 

 

DANGER!  Never use brake cleaner or any chlorinated solvent to clean or degrease metal 
scheduled to be welded or other related equipment in the area being welded.  The heating 
of this cleaner and its residue will create highly toxic phosgene gas.  Small amounts  of 
this vapor are harmful and can lead to organ failure and death.  If degreasing of a part is 
necessary, use Acetone or an approved pre

-

weld cleaner. Use the proper personal protec-

tive equipment (PPE) when handling any cleaners/solvents.

 

 

DANGER!  People with pacemakers should consult a physician and pacemaker manufactur-
er before welding.  There is a potential for damage or serious malfunction resulting in 
death.  High Frequency energy (HF)/Electromagnetic Fields generated during welding can 
interfere with pacemaker signals, even permanently damaging it.  Some pacemakers offer 
some shielding, but restrictions regarding amperage and HF starting of TIG arcs may be 
placed upon the individual.  Warn all potential bystanders that they should exit the work 
area if they have a pacemaker or similar medical equipment before welding. Severe electri-
cal shock leading to injury or death may occur while using the plasma cutter if the user 
becomes part of the circuit path. While the Amp output of the plasma cutter is limited, the 
unit may produce an OCV of 300V or greater.  Consult with a Physician if a pacemaker is 
expected to be implanted.  

 

 

DANGER!  Never defeat or modify any safety guards or shields.  Keep all safety covers and 
shields in place.

 

Never place your fingers in or near a fan shroud or insert any object into the fan(s).

 

 

DANGER! Always switch the Foot Pedal/Transmitter to the off position when not in use or 
when storing. Accidental activation may cause severe shock, arc flashing, burns or other 
injury or damage.  This will also help to preserve the battery and keep it charged.

 

Содержание NVA-FT06

Страница 1: ...erator s Manual Publish Date 7 1 22 NVA FT06 North America NOVA Welding Industries WIRELESS TIG FOOT PEDAL 2 4 GHz MODEL NVA FT06 SERIAL NUMBER APPLICATION FCC PEDAL TRANSMITTER ID FCC RECEIVER ID OTH...

Страница 2: ...ESS PEDAL 13 TROUBLESHOOTING 15 RECYCLE DO NOT DISCARD THIS PRODUCT IN THE TRASH This Wireless Pedal has been designed for a long life However in the event part s or all of this product becomes non se...

Страница 3: ...has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interf...

Страница 4: ...hen not in use Please carefully read this manual before you install and operate your NOVA TIG foot pedal The warranty does not cover damage or harm created by improper use neglect of the pedal or fail...

Страница 5: ...sleeved flame resistant clothing i e denim Do not wear Poly Nylon blend materials DANGER Welding cutting poses shock and electrocution risks Keep this welding equip ment dry Do not weld in the rain or...

Страница 6: ...death If degreasing of a part is necessary use Acetone or an approved pre weld cleaner Use the proper personal protec tive equipment PPE when handling any cleaners solvents DANGER People with pacemak...

Страница 7: ...nt PPE suitable for welding to stand in the welding area or to observe weld ing and welding related activities If protection is not readily available use a welding screen to separate the welding area...

Страница 8: ...n average useage and ex pected time on of the foot pedal Leaving foot pedal switched on in storage or while not in use will drain battery Model Compatibility For The NOVA Wireless Pedal Adapter Pedal...

Страница 9: ...F SWITCH BATTERY TO TRANSMITTER CONNECTORS CHARGER FOR PEDAL CHARGING LIGHT RED CHARGING GREEN CHARGED CHARGING PORT CONNECTOR CONTROL ADAPTER FROM DONGLE CONNECTOR TO WELDER TYPE VARIES BY BRAND NOT...

Страница 10: ...to go together you may need to make sure the pressure return spring is flipped so that it pushes back against the pedal as it is assembled There will be moderate resistance as the pe dal goes togethe...

Страница 11: ...tting is governed by the welder default or start setting selected by the user PAIRING OF PEDAL AND RECIEVER The pedal arrives already paired synchronized to the receiver from the factory There is no n...

Страница 12: ...st 4 hours until the LED turns from red to green Once the LED turns green remove the charger Keep the pedal switched to OFF until the pedal is ready for use Remember to turn the switch to OFF position...

Страница 13: ...ting that you would use with your welder when using a foot pedal Select the maximum Amperage you wish to use with the pedal Set your welder normally as you would with any foot pedal including start se...

Страница 14: ...ot all weld ers can be used with the NOVA wireless pedal Older non digi talized welders will often not be able to work with this unit If in doubt consult the NOVA product compatibility information on...

Страница 15: ...t off cleanly or properly Improper machine settings Turn off down slope Pedal is not fully back to stop Press on rear of pedal to make sure the pedal is in the fully up position and the micro switch i...