Document 51996 AFP-300/400 NION Installation Rev. A1 03/04/03
1.1 Description of the AFP-300/400 NION
The AFP-300/400 NION (Network Input Output Node) is the EIA-232 interface used with the network. All of the
system components are based on LonWorks™ (Local Operating Network) technologies. The AFP-300/400 NION
provides transparent or interpreted communications between the Workstation and control panels. Unless otherwise
noted, full control capabilities are available for each interface. Check specific connections for details.
The NION connects a LonWorks™ FT-10 or fiber optic network, and the EIA-232 port of control panels. It
provides a two-way communication channel for EIA-232 serial data when connected to a control panel. NIONs
are specific to the type of network to which they connect (FT-10 or fiber). The LonWorks™ network interface
accepts any standard SMX style transceiver (FTXC, S7FTXC, FOXC, or DFXC). The transceiver type must be
specified and ordered separately when ordering the NION.
The NION mounts in an enclosure (NISCAB-1 or CHS-4L in CAB-3 or CAB-4 series enclosure - sold separately)
with conduit knockout.
W
W
W
W
Workstation
orkstation
orkstation
orkstation
orkstation
Local Area Server
Local Area Server
Local Area Server
Local Area Server
Local Area Server
AFP
AFP
AFP
AFP
AFP-300/400 NION
-300/400 NION
-300/400 NION
-300/400 NION
-300/400 NION
(AFP
(AFP
(AFP
(AFP
(AFP-300/400 NION)
-300/400 NION)
-300/400 NION)
-300/400 NION)
-300/400 NION)
NO
NO
NO
NO
NOTE
TE
TE
TE
TE: The NION is installed in the
: The NION is installed in the
: The NION is installed in the
: The NION is installed in the
: The NION is installed in the
cabinet with the AFP
cabinet with the AFP
cabinet with the AFP
cabinet with the AFP
cabinet with the AFP-300/400 F
-300/400 F
-300/400 F
-300/400 F
-300/400 FA
AA
AACP*)
CP*)
CP*)
CP*)
CP*)
AFP
AFP
AFP
AFP
AFP-300/400 F
-300/400 F
-300/400 F
-300/400 F
-300/400 FA
AA
AACP*
CP*
CP*
CP*
CP*
*FACP: Fire Alarm Control Panel
NOTE: This NION is only compatible with UniNet
2.0 and later Workstation software.
When upgrading from the older AFP
When upgrading from the older AFP
When upgrading from the older AFP
When upgrading from the older AFP
When upgrading from the older AFP-300/400 NION-232B board, the database conversion utility
-300/400 NION-232B board, the database conversion utility
-300/400 NION-232B board, the database conversion utility
-300/400 NION-232B board, the database conversion utility
-300/400 NION-232B board, the database conversion utility
needs to be run before installing the new AFP
needs to be run before installing the new AFP
needs to be run before installing the new AFP
needs to be run before installing the new AFP
needs to be run before installing the new AFP-300/400 NION board. The conversion utility will
-300/400 NION board. The conversion utility will
-300/400 NION board. The conversion utility will
-300/400 NION board. The conversion utility will
-300/400 NION board. The conversion utility will
alter existing device IDs in the screen database to match the new format used by this NION
alter existing device IDs in the screen database to match the new format used by this NION
alter existing device IDs in the screen database to match the new format used by this NION
alter existing device IDs in the screen database to match the new format used by this NION
alter existing device IDs in the screen database to match the new format used by this NION. Any
. Any
. Any
. Any
. Any
UniL
UniL
UniL
UniL
UniLogic equations from the old system must be recreated after installing the new AFP
ogic equations from the old system must be recreated after installing the new AFP
ogic equations from the old system must be recreated after installing the new AFP
ogic equations from the old system must be recreated after installing the new AFP
ogic equations from the old system must be recreated after installing the new AFP-300/400
-300/400
-300/400
-300/400
-300/400
NION
NION
NION
NION
NION.....
See Appendix A for details on the conversion utility
See Appendix A for details on the conversion utility
See Appendix A for details on the conversion utility
See Appendix A for details on the conversion utility
See Appendix A for details on the conversion utility.....
Section One: Description and Installation
1
FIgure 1-1: NION Architecture Diagram
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com