d. Use screened cables to comply with the

EMC  requirements  and  reduce  the

possibility of external interference.

The  following  table  lists  cables  tested  and

maximum distances achieved:

Each link in a network may be either copper-

conductor cable or optical fibre.

Caution: To ensure specified performance

use only 2-core, screened cables.

On  no  account  must  multi-core

cables be used.

3.3.1 Fibre-optic Cable Limits

The fibre-optic link used by the ID

2

net network

has the following specification:

a. Connector style

ST

b. Link

Duplex (Twin Fibre)

c. Wavelength

820nm

d. Fibre Type

Multi-mode

Parameter

Min. (dB) Typical (dB)

Optical Power Budget

50/125µm Fibre

4.2

9.6

Optical Power Budget

62.5/125µm Fibre

8.0

15

Notes:
1

For a typical 62.5/125 cable, attenuation is

2.8dB/km which gives a typical link length

of 15/2.8 = 5300m.

2

Using  worst-case  figures,  attenuation  of

4.5dB/km gives a link length of:

8/4.5 = 1800m.

3

For  a  specific  design,  substitute  the

attenuation figure for the fibre to be used

into the calculation.

4

Allowance  should  be  made  for  any

additional splices or connectors used.

Cable Type

Recommended

Max. Test

 Operating Distance (m) Distance (m)

Pirelli FP200 Flex 1.5mm

2

850

1000

Draka Firetuf FDZ2ER (1.5mm

2

/2.5mm

2

)

1200

1400

AEI MICC 2L1.5 (1.5mm

2

)

1200

1400

AEI Firetec F2CxxE (1.0mm

2

/1.5mm

2

)

1350

1600

Pirelli FP200 Gold 1.5mm

2

1700

2000

Содержание ID2net

Страница 1: ...ID2 net Installation commissioning manual 997 448 000 2 Issue 2 July 2004 ...

Страница 2: ...Hardware Requirements 5 3 1 1 Network Gateway Module PCB 5 3 1 2 Fibre optic Interface PCB 5 3 2 Earth Fault Detection 6 3 3 Cables 6 3 3 1 Fibre optic Cable Limits 7 4 Configuring Panels on the Network 8 4 1 Off line Configuration Tool 8 4 2 Assigning Panels to the Network 8 4 2 1 Location Text 10 4 2 2 Repeaters 10 5 Trouble Shooting Guide 12 5 1 Fault Messages Possible Causes and Remedies 12 5 ...

Страница 3: ... network Other key features included are a Up to 32 panels 100 nodes per network capability b Single fault tolerance using simultaneous bi directional message transmission c Fast message transmission time d Short circuit open circuit and earth fault protection per link e Verified delivery with automatic re try if required f Message delivery using token passing avoids multiple collisions g Predicta...

Страница 4: ...ration Manual 2 997 448 000 2 Issue 2 July 2004 Introduction 1 1 1 Software Version The panel Loop PCB and ID2 net software versions are displayed when performing a Lamp Test Refer to the ID3000 Series Operating Manual ref 997 275 ...

Страница 5: ...et includes two ARCNET microprocessors where each is capable of working independently of the other This allows a networked fire control panel to communicate simultaneously with the panels either side of it The drawing at left shows eight panels networked together in a continuous loop arrangement It can be seen that conceptually total networking of all eight panels is achieved through an arrangemen...

Страница 6: ...cal fibre cables c A mixture of conventional and optical fibre cables The ID2 net Network PCB is provided with two wiring connectors J1 and J2 located along the top edge of the PCB for data interconnection with other panels using conventional cables see example A at left A ribbon cable connector J3 provided on the left hand edge of the Network PCB is used for connection to an optional Interface PC...

Страница 7: ...fitted in the panel s main chassis enclosure 3 1 1 Network Gateway Module PCB The Network Gateway Module NGM PCB PN 124 312 must be fitted on the right hand side of the main chassis enclosure It plugs directly into the Processor PCB For details on fitting the NGM PCB setting the network configuration jumper links and connecting external cables refer to instruction sheet ref 997 449 supplied with i...

Страница 8: ...er as the link between NGUs cannot be monitored for earth faults 3 3 Cables Conventional copper conductor cable types can be used for the communication link between networked nodes NOTIFIER recommend the use of MICC with a LSF PVC overcovering a fire resilient cable to BS7629 or PVC SWA PVC to BS6387 Alternatively for longer inter node distances fibre optic cables may be used the optional Fibre op...

Страница 9: ...Duplex Twin Fibre c Wavelength 820nm d Fibre Type Multi mode Parameter Min dB Typical dB Optical Power Budget 50 125µm Fibre 4 2 9 6 Optical Power Budget 62 5 125µm Fibre 8 0 15 Notes 1 For a typical 62 5 125 cable attenuation is 2 8dB km which gives a typical link length of 15 2 8 5300m 2 Using worst case figures attenuation of 4 5dB km gives a link length of 8 4 5 1800m 3 For a specific design s...

Страница 10: ...e is defined as a point on the network that can be addressed by any other point by its identification number When the ID2 net Peer to Peer Configuration menu screen is displayed for the first time no configuration data will exist for any node on the network Data is entered at each node in turn until all have been assigned to the network This does not have to be done in any particular order The net...

Страница 11: ...ned When you reach the node number you wish to assign to the panel you are currently working at move the cursor to the This column and press the pushbutton This selection must only bedoneonceforeachpanel If you have made an error move the cursor up or down using the and pushbuttons to the correct node addressandpressthe pushbutton thisaction will automatically clear the tick from the incorrect pos...

Страница 12: ...ed at ALL other stations on the network 4 2 2 Repeaters Note This procedure is described assuming that you are familiar with using the panel control keys to navigate the menus and how to make appropriate option selections If in doubt refer to Section 4 2 Assigning Panels to Network This option allows the configuration of repeaters on networked panels using the RS485 communications link Refer to th...

Страница 13: ...S485 PCB is correctly installed in any panel where repeaters are to be configured To clear the FAULT tab repeat the procedure by entering a zero quantity for repeaters confirm and press RESET Alternatively fit an RS485 PCB and repeat the procedure entering the correct number of repeaters Note The RS485 PCB should only be fitted with the panel powered down Refer to the ID3000 Series Installation Co...

Страница 14: ...occur individually or together The Network startup fault message is displayed if either of the following situations occur a Failure of the NGM PCB to start initially or b Failure of the NGM PCB to start after the occurence of a runtime fault such as a panel NGM PCB communication loss The Network runtime fault is displayed only if the NGM PCB stopped working after a period of working correctly If t...

Страница 15: ...n Warning Messages If a panel has already been configured as part of a Master Slave network and an attempt is made to configure it as an ID2 net peer to peer network a warning message is displayed as follows WARNING this panel is already configured as a member of a Master Slave network This is incompatible with ID2 net Peer to Peer Network If a panel has already been configured as part of a ID2 ne...

Страница 16: ...tems co uk local distributor Every care has been taken in the preparation of this document but no liability can be accepted for the use of the information therein Design features may be changed or amended without prior notice Quality Systems Certificate No 154 Assessed to ISO9001 L O S S P R E V E N T ION CERTIFI C A T I O N B O A R D 007 ...

Отзывы: