background image

Power Supply Calculations

DC Current Draw Calculations

32

ACPS-2406 PN 51304:B 09/02/2003

Table 5.2  DC Current Draw Calculations, Output 2

Table 5.3  DC Current Draw Calculations, Output 3

OUTPUT 2

C

ATEGORY

COLUMN A

S

TANDBY

 C

URRENT

 (

AMPS

)

COLUMN B

A

LARM

 C

URRENT

 (

AMPS

)

Q

TY

CURRENT

 

DRAW

=

T

OTAL

Q

TY

CURRENT

 

DRAW

=

T

OTAL

Power Supervision Relays (A77-716B)

 

X                        =

A

 

X                        =

A

4-Wire Smoke Detectors

 

X                        =

A

X                        =

A

4-Wire Smoke Detectors

 

X                        =

A

X                        =

A

Annunciators

 

X                        =

A

X                        =

A

Auxiliary Devices

 

X                        =

A

X                        =

A

Auxiliary Devices

 

X                        =

A

X                        =

A

Auxiliary Devices

 

X                        =

A

X                        =

A

Notification Appliances

N

OT

 A

PPLICABLE

X                        =

A

Notification Appliances

      X                        =

A

Notification Appliances

 

X                        =

A

S

UM

 

EACH

 

COLUMN

 

FOR

 

TOTALS

 O

UTPUT

 2 

S

TANDBY

 

C

URRENT

 

TOTAL

:

A

O

UTPUT

 2

ALARM

C

URRENT

 

TOTAL

:

A

Note:    S

TANDBY

 C

URRENT

 T

OTAL

 for all outputs together cannot exceed 1.0  A.

            A

LARM

 C

URRENT

 T

OTAL

 cannot exceed 2.50 A for any single output.

OUTPUT 3

C

ATEGORY

COLUMN A

S

TANDBY

 C

URRENT

 (

AMPS

)

COLUMN B

A

LARM

 C

URRENT

 (

AMPS

)

Q

TY

CURRENT

 

DRAW

=

T

OTAL

Q

TY

CURRENT

 

DRAW

=

T

OTAL

Power Supervision Relays (A77-716B)

 

X                        =

A

 

X                        =

A

4-Wire Smoke Detectors

 

X                        =

A

X                        =

A

4-Wire Smoke Detectors

 

X                        =

A

X                        =

A

Annunciators

 

X                        =

A

X                        =

A

Auxiliary Devices

 

X                        =

A

X                        =

A

Auxiliary Devices

 

X                        =

A

X                        =

A

Auxiliary Devices

 

X                        =

A

X                        =

A

Notification Appliances

N

OT

 A

PPLICABLE

X                        =

A

Notification Appliances

      X                        =

A

Notification Appliances

 

X                        =

A

S

UM

 

EACH

 

COLUMN

 

FOR

 

TOTALS

O

UTPUT

 3 

S

TANDBY

 

C

URRENT

 D

RAW

 

TOTAL

:

A

O

UTPUT

 3

ALARM

C

URRENT

 D

RAW

 

TOTAL

:

A

Note:    S

TANDBY

 C

URRENT

 T

OTAL

 for all outputs together cannot exceed 1.0  A.

            A

LARM

 C

URRENT

 T

OTAL

 cannot exceed 2.50 A for any single output.

Содержание ACPS-2406

Страница 1: ...Addressable Charger Power Supply ACPS 2406 Manual B PN 51304 B ECN 03 366 Document 51304 09 02 2003 Rev...

Страница 2: ...te warning of fires caused by arson children playing with matches especially in bedrooms smoking in bed and violent explosions caused by escaping gas improper storage of flammable materials etc Heat d...

Страница 3: ...assemblies prior to any drilling filing reaming or punching of the enclosure When possible make all cable entries from the sides or rear Before making modifi cations verify that they will not interfer...

Страница 4: ...information Product name and version number if applicable Printed manual or online Help Topic Title for online Help Page number for printed manual Brief description of content you think should be impr...

Страница 5: ...06 16 DIP Switch Configuration 16 Addressing 18 Determining Address Consumption 18 Setting the Base Address 20 Panel Programming Requirements 22 Panel Addressing 22 Software Type ID Codes 23 Dual Stag...

Страница 6: ...Table of Contents 6 ACPS 2406 PN 51304 B 09 02 2003...

Страница 7: ...7 to 25 AH batteries Auxiliary 24 VDC 0 5 A output for use within the same cabinet Isolated Signaling Line Circuit SLC interface Brownout detection Battery battery charger supervision AC loss detectio...

Страница 8: ...t approximately 3 33k baud Battery fuse F2 15A 3AB Line Drop 2 4 VDC max to last device 1 3 Installation Standards and Codes The ACPS 2406 complies with the following standards NFPA 72 National Fire A...

Страница 9: ...AFP 200 Analog Fire Panel 15511 AFP 300 AFP 400 Analog Fire Panel 50253 50259 50260 AFC 600 Analog Fire Control Panel 51031 51032 51033 UZC 256 Universal Zone Coder Installation Guide 15216 CAB 3 Seri...

Страница 10: ...this jumper to disable ground fault detection Auxiliary Power Supply Rotary Switch JP6 AC SLC A SLC B UZCSUP NEUT EARTH GROUND BAT OUT BAT OUT BAT IN BAT IN Output 1 NAC 1 NAC 2 NAC 3 NAC 4 Locations...

Страница 11: ...munication is established with the FACP Blinks steadily during normal polling process D68 NAC 3 Green Glows steadily when communication is established with the FACP Blinks steadily during normal polli...

Страница 12: ...0 D7 1 D7 2 D8 1 BATT IN BAT T O U T B ATT IN B AT T O UT OP TION S OP TION S D7 5 _ _ 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 D54 D7 3 H OT N EU T RA L E A RT H D74 D 47 TB 5 TB 6 TB 8 TB 1 T B 3 TB 2 TB 4 D...

Страница 13: ...2 4 BB 25 Cabinet Power limited Wiring Example with Two Battery Wiring D54 D73 H OT NEUTRA L EARTH D74 D4 7 TB5 TB6 TB8 TB1 TB3 TB2 TB4 D4 0 D32 D6 6 OU TP UT 1 4 W IR E OU TP UT 2 4 WIRE OU TP UT 3...

Страница 14: ...75 _ _ 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 Output Circuit Wiring Power limited Supervised except for TB6 UZCSUP UZCSUPRET TB1 AC Primary Power Wiring nonpower limited and supervised acps6cab3wiring CDR D...

Страница 15: ...tions suggestions Outputs 1 through 4 share 6 0 A of output power when configured as NACs or 5 0 A of 24VDC detector power or general purpose power TB8 SLC Wiring Connect to panel Signaling Line Circu...

Страница 16: ...d in Table 3 1 SW2 and SW3 are horizontally aligned on the ACPS 2406 board just above the metal case which covers the bottom half of the power supply To place a switch in the OFF position depress the...

Страница 17: ...ization input UZC connections at TB6 Switch SW2 ON OFF 2 1 Output Circuit 1 is coded if configured as NAC with SW3 1 resettable if configured as 24VDC power circuit with SW3 1 Output Circuit 1 is nonc...

Страница 18: ...B 2 SW3 4 ON or OFF 4 ACPS 2406 Output 3 B 3 SW3 5 Any combination except 3 5 ON 3 6 ON Canadian Trouble Reporting 5 ACPS 2406 Output 4 B 4 SW3 6 Not selected 6 Signal Silence Address SW3 7 Any combin...

Страница 19: ...3 ON or OFF 3 ACPS 2406 Output 2 B 2 SW3 4 ON or OFF 4 ACPS 2406 Output 3 B 3 SW3 5 3 5 ON 3 6 ON Canadian Trouble Reporting 5 ACPS 2406 Output 4 B 4 SW3 6 6 Signal Silence Address B 5 SW3 7 Any comb...

Страница 20: ...a shunt plug to further define the addresses They select the number that ends with zero or five in the decade defined by the rotary switch Placing the shunt plug over the two pins closest to the 0 se...

Страница 21: ...ock Figure 3 2 below gives two examples of setting the base address with rotary switch and JP6 shunt plug settings Note that the base address plus the number of addresses in the address block minus on...

Страница 22: ...may be skipped Table 3 8 FACP Addressing FACP Order of ACPS 2406 Address Assignment ACPS 2406 Addresses 1 Monitor General 2 ACPS 2406 Output 1 3 ACPS 2406 Output 2 4 ACPS 2406 Output 3 5 ACPS 2406 Ou...

Страница 23: ...The installer should ascertain that an appropriate block of consecutive FACP addresses is available prior to addressing an ACPS 2406 in Dual Stage Refer to Table 3 6 and Table 3 7 for information on A...

Страница 24: ...ftware Zone Z200 RZON is programmed to activate after a 5 minute delay with the equation Z200 DEL 00 05 00 L1M3 Z200 will clear or never activate if L1M1isacknowledgedor ifthesystem is reset before th...

Страница 25: ...will activate when the Z2 equation is satisfied EVAC OR Z2 Z201 The CBE in this equation refers to any local CBE that is programmed into this point It could be a CBE that programs four or more cross z...

Страница 26: ...2K to terminate Style Y Class B NAC ELRs should not be used when Style Z Class A return is wired Note The NAC outputs shown above are in a non coded configuration TB5 T 6 B TB4 OUTPUT 1 OUT1 OUT1 OUT...

Страница 27: ...when used with a UZC 256 Universal Zone Coder if the NAC output is configured for coded signals only Note 1 Do not place strobes from any manufacturer onto a coded output For example SpectrAlert Serie...

Страница 28: ...ttings 2 1 OFF 3 1 OFF 2 5 ON 2 6 OFF 2 7 ON 3 7 OFF 3 8 OFF DIP Switches SW 2 8 3 5 and 3 6 also require setting to determine AC and battery charger information See Table 3 1 ACPS6app1 cdr 100 ohm ma...

Страница 29: ...er may not be used on coded buses No NAC devices may be on the synchronization riser This riser must be in the same cabinet as the FACP or within 20 feet 6 1m in conduit or it must be supervised with...

Страница 30: ...with no barriers all strobe devices on the NAC outputs of one power supply must be at least 55 feet 16 76 m in distance from all strobe devices on the NAC outputs of another power supply 4 Use only d...

Страница 31: ...put 4 in Table 5 4 Refer to the Device Compatibility document and the device manufacturer s data sheets packaged with each device to find the standby and alarm current draws to use in these tables 2 E...

Страница 32: ...ANDBY CURRENT TOTAL A OUTPUT 2 ALARM CURRENT TOTAL A Note STANDBY CURRENT TOTAL for all outputs together cannot exceed 1 0 A ALARM CURRENT TOTAL cannot exceed 2 50 A for any single output OUTPUT 3 CAT...

Страница 33: ...liances X A Notification Appliances X A SUM EACH COLUMN FOR TOTALS OUTPUT 4 STANDBY CURRENT DRAW TOTAL A OUTPUT 4 ALARM CURRENT DRAW TOTAL A If a load is put on the Auxiliary Power Output J1 enter the...

Страница 34: ...eater than 25 0 AH disable internal charger by setting SW3 7 to OFF and use an external battery charger LOAD TOTALS MULTIPLY BY TIME EQUALS SECONDARY AMP HOUR TOTALS Enter Standby Current Amps Total f...

Страница 35: ...ry fuse 8 Battery battery charger supervision 7 BB 25 Cabinet 9 12 Bells synchronization of 27 Board Layout ACPS 2406 10 Brownout detection 7 11 C CAB 3 Series Cabinets 9 12 14 CAB PS1 Cabinet 9 13 14...

Страница 36: ...n 21 average current 8 data transmission 8 determining address block size 18 maximum resistance 8 Wiring 15 Snap on cover 12 15 Software Type ID Codes 23 Specifications 7 Auxiliary Power Output 7 Outp...

Страница 37: ...ACPS 2406 PN 51304 B 09 02 2003 37 NOTES...

Страница 38: ...38 ACPS 2406 PN 51304 B 09 02 2003 NOTES...

Страница 39: ...ion prepaid to NOTIFIER 12 Clintonville Road Northford Connecticut 06472 1653 This writing constitutes the only warranty made by NOTIFIER with respect to its products NOTIFIER does not represent that...

Страница 40: ...NOTIFIER is a company World Headquarters 12 Clintonville Road Northford CT 06472 1653 USA 203 484 7161 fax 203 484 7118 www notifier com...

Отзывы: