2
Plasma Cutter
Operating Instructions and Parts Manual
Plasma Cutter
Plasma 275
Know your Welder
Gas Pressure Display
The built-in gas display is used for reading the output gas pressure when cutting.
Gas Pressure Adjustor
It is used for adjusting the gas pressure. The gas pressure can be read from the
gas pressure display on the front panel. Normally, the pressure should be
adjusted between 55-90psi.
When cutting, this light is on to show the unit is on working mode.
Work Indicator
Cutting Chart
Handle
Gas Pressure
Cutting chart
Display
Gas Pressure
Adjustor
Connector for
Cutting Torch
Connector for
Grounding Cable
Connector for Torch
Arc Starting Cable
Cutting Torch
Grounding Cable
with Clamp
Nozzle
Electrode
This chart indicates the thickness of different types of materials that .
this unit can cut at a rate of 10 inches per minute.It also shows sever capacity.
Sever thicknesses may take more time than 10 inches per minute
Material
Clean cut
Sever
Mild steel
5/32″
1/4″
Stainless steel
1/8″
3/16″
Galvanized
1/8″
5/32″
Aluminum
3/32″
1/8″
Copper
1/16″
3/32″
Brass
1/16″
3/32″