norweco SERVICE PRO WASP SERIES Скачать руководство пользователя страница 2

©MMXVI NORWECO, INC. NORWALK, OHIO U.S.A.

MANUFACTURED BY

NORWECO, INC.

NORWALK, OHIO

U.S.A.  44857

www.norweco.com

SERVICE PRO

®

 WASP START-UP AND OPERATION (Cont.)

8.  If the CYCLE TIMER mode has been selected, press 

the right arrow button on the touchpad to set the pump 

on time.  This is the length of time that the pump will 

operate each cycle.

a.  “PUMP CYCLE ON TIME” and “SET HOURS” will 

be displayed on the screen.  Press the up or down 

arrow button to set the desired hours value. 

b.  Once the correct hours value has been set, press 

the right arrow button to set the minutes value.  The 

display will read “SET MINUTES”.  Press the up 

or down arrow button to set the desired minutes 

value.

c.  Once the correct minutes value has been set, press 

the right arrow button to set the seconds value.  The 

display will read “SET SECONDS”.  Press the up 

or down arrow button to set the desired seconds 

value.

d.  Once  the  correct  seconds  value  has  been  set, 

press the right arrow button to set the pump 

off time.  “PUMP CYCLE OFF TIME” and “SET 

HOURS” will be displayed on the screen.  Press the 

up or down arrow button to set the desired hours 

value. 

e.  Once the correct hours value has been set, press 

the right arrow button to set the minutes value.  The 

display will read “SET MINUTES”.  Press the up 

or down arrow button to set the desired minutes  

value.

f.  Once the correct minutes value has been set, press 

the right arrow button to set the seconds value.  The 

display will read “SET SECONDS”.  Press the up 

or down arrow button to set the desired seconds 

value.

9.  Press the right arrow button on the touchpad to enter the 

auxiliary input alarms configuration screen.  The display 

will read “AUXILIARY ALARMS” and the AUX1 value 

should be selected.  Press the up or down arrow button 

to change the auxiliary 1 input from N-OP (normally 

open) to N-CL (normally closed) if required.  If auxiliary 

input 1 will not be used, leave AUX1 set to N-OP.

10. Once auxiliary input 1 has been configured, press the 

right arrow button on the touchpad to configure auxiliary 

input 2.  The AUX2 value should be selected.  Press the 

up or down arrow button to change the auxiliary 2 input 

from N-OP (normally open) to N-CL (normally closed) 

if required.  If auxiliary input 2 will not be used, leave 

AUX2 set to N-OP.

11. Once auxiliary input 2 has been configured, press the 

right arrow button on the touchpad to configure auxiliary 

input 3.  The AUX3 value should be selected.  Press the 

up or down arrow button to change the auxiliary 3 input 

from N-OP (normally open) to N-CL (normally closed) 

if required.  If auxiliary input 3 will not be used, leave 

AUX3 set to N-OP.

12. Press the right arrow button on the touchpad to exit 

the programming menu.  The display should read 

“SERVICE PRO OK” on the top line. The Service Pro 

WASP control center programming is complete and the 

system is now ready for operation.

VIEW SYSTEM STATUS AND CONFIGURATION

The Service Pro WASP control center records parameters 

regarding the Singulair system that can be reviewed at any 

time.  Adjustments to the programming can be made as 

required.  To review recorded data and system parameters:

1.  Press  the  “SELECT”  button  on  the  touchpad.    The 

screen should display the elapsed pump run time.

2.  Press the right arrow button to review the pump cycle 

count.

3.  Press the right arrow button to review the aerator 

elapsed run time.

4.  Press the right arrow button to review the aerator cycle 

count.

5.  Press the right arrow button to review the auxiliary input 

configurations.

6.  Press the right arrow button to review failsafe mode 

status, software version and panel serial number.

7.  Press the right arrow button to exit the system 

parameters menu.

PUMP TEST

The Service Pro WASP control center has a built-in pump 

test feature.  To start a pump test, hold the “PUMP TEST” 

button for five seconds.  The screen will display “PUMP 

TEST” and the pump will turn on.  The pump will operate 

for five minutes and then will turn off.

ALARM TEST

The Service Pro WASP control center has a built-in alarm 

test  feature.   To  start  an  alarm  test,  hold  the  “ALARM 

RESET” button for five seconds.  The screen will display 

“ALARM TEST”  and  the  audible  and  visual  alarms  will 

turn on for five seconds.   After five seconds, the alarms 

will turn off.

ALARM CONDITIONS

If the Service Pro WASP control center detects an abnormal 

condition,  the  display  will  indicate  the  specific  problem 

the system is experiencing.  For example, if the aerator is 

drawing high amps, the display will read “AERATOR HIGH 

CURRENT.”  To silence the alarms and attempt to clear 

the alarm condition, press the “ALARM RESET” button.  If 

the issue has been corrected, the system will turn off the 

alarms  and  resume  normal  operation.    If  a  problem  still 

exists, the audible alarm will be silenced for 48 hours, but 

the visual alarm will continue to light.  In addition, detailed 

information regarding the specific problem will be displayed 

on the screen.

Отзывы: