norweco SERVICE PRO WASP SERIES Скачать руководство пользователя страница 1

WASP SERIES INTEGRATED SYSTEM CONTROLS

START-UP AND OPERATION INSTRUCTIONS

The information contained in these instructions is not intended to be a complete electrical installation reference, as code 

requirements vary according to geographic area. These instructions focus only on the specific requirements for the Service 

Pro WASP controls. They do not cover all installation aspects of the underground electrical cable and control center, 

preliminary inspection, testing and service of the control center or troubleshooting. More instructions are contained in the 

Bio-Kinetic Wastewater Treatment System Electrical Wiring and Control Center Installation yellow sheet. All electrical work 

must be performed in accordance with the latest edition of the National Electrical Code and all applicable local codes.

PROGRAMMING THE PANEL

1.  After wiring has been completed, the Service Pro WASP 

control center must be programmed to operate the 

Singulair system.  Make sure the breakers in the home 

and in the panel are both in the “on” position and the 

display in the control center reads “SERVICE PRO OK” 

on the top line.

2.  Press the “MENU” button on the touchpad to access the 

programming menu of the control center.  “SET CLOCK” 

and  “SET  HOURS”  will  be  displayed  on  the  screen.  

Press the up or down arrow button on the touchpad to 

set the correct hours value.

3.  Once the correct hours value is displayed, press the 

right arrow button to set the minutes value.  The display 

will read “SET MINUTES”.  Press the up or down arrow 

button to set the correct minutes value.  

4.  Once the correct minutes value is displayed, press the 

right arrow button to set the seconds value.  The display 

will read “SET SECONDS”.  Press the up or down arrow 

button to set the correct seconds value.

5.  Once  the  correct  seconds  value  is  displayed,  press 

the  right arrow button on the touchpad to set the aerator 

run time.  The display will read “AERATOR RUN TIME”. 

Press the up or down arrow button to change the aerator 

run time in one minute increments.  This value can be 

set from 30 minutes up to continuous operation.

6.  Once the aerator run time has been set, press the right 

arrow button button on the touchpad to set the pump 

timer  mode.    The  display  will  read  “PUMP  TIMER 

MODE”.  Press the up or down arrow button to change 

the timer mode.  Available options include NO TIMER 

mode, TIME OF DAY mode and CYCLE TIMER mode.  

NO TIMER  mode  operates  the  pump  on  a  demand 

use basis controlled by the float switches.  TIME OF 

DAY mode enables the pump to operate at a set time 

range during the day and works in conjunction with the 

float switches.  CYCLE TIMER mode enables pump 

operation on a repeat cycle and works in conjunction 

with  the  float  switches.  For  TIME  OF  DAY  mode, 

proceed to step 7 below.  For CYCLE TIMER mode, 

proceed to step 8 below.

7.  If the TIME OF DAY mode has been selected, press the 

right arrow button on the touchpad to set the pump on 

time.  This is the time of day that the pump will begin 

operating.

a.  “PUMP  ON  TIME”  and  “SET  HOURS”  will  be 

displayed on the screen.  Press the up or down 

arrow button to set the desired hours value. 

b.  Once the correct hours value has been set, press 

the right arrow button to set the minutes value.  The 

display will read “SET MINUTES”.  Press the up or 

down arrow button to set the desired minutes value.

c.  Once  the  correct  minutes  value  has  been  set, 

press the right arrow button to set the pump off 

time.  This is the time of day that the pump will be 

disabled.  “PUMP OFF TIME” and “SET HOURS” 

will be displayed on the screen.  Press the up or 

down arrow button to set the desired hours value. 

d.  Once the correct hours value has been set, press 

the right arrow button to set the minutes value.  The 

display will read “SET MINUTES”.  Press the up or 

down arrow button to set the desired minutes value.

e.  Proceed to step 9 below.

WASP SERIES CONTROLS

Отзывы: