-11 -

8. W

IRING

 D

IAGRAMS

 (

CONT

D

)

27 kW 208 VAC

3-Phase

24 kW 208 VAC

3-Phase

13.5 kW 208 VAC

3-Phase

K2 240V

1

5

2

3

6

4

240

VAC

NC

R

BL

Y

BL

C

BK

W

BK

K1 24V

1

5

2

3

6

4

24V

AC

K1 24V

1

5

2

3

6

4

24V

AC

BK

R

M

Y

BL

C

W

BK

R

BK

BK

M

K2 240V

1

5

2

3

6

4

240

VAC

NC

BK

BK

R

L1

L3

L2

G

Class 2 Transformer

Pri: 240 V 60 Hz

Sec: 24 V 60 Hz 40 VA

Y

T

Y

Y

BK

R

Class 2 Transformer

Pri: 240 V 60 Hz

Sec: 24 V 60 Hz 40 VA

Y

T

Y

Y

BK
R

W

Open: 93.3°C

MRTP 1

MRTP 2

BL

W

Open: 93.3°C

MRTP 1

MRTP 2

BL

24 VAC
COMMON OUT

24 VAC
POWER OUT

CALL FOR FAN

CALL FOR
HEAT 1

CALL FOR
HEAT 2

BK

HEAT INDICATOR

C

G

R

W1

W2

TB

Y

BK

24 VAC
COMMON OUT

24 VAC
POWER OUT

CALL FOR FAN

CALL FOR
HEAT 1

CALL FOR
HEAT 2

BK

HEAT INDICATOR

C

G

R

W1

W2

TB

Y

BK

BL

Season Select

BL

BL

BL

BL

BL

W

BK

BK

R

HEAT 2

E

ARTP

R

HEAT 3

E

ARTP

R

HEAT 1

E

ARTP

R

HEAT 4

E

ARTP

R

HEAT 5

E

ARTP

R

HEAT 6

E

ARTP

R

BL

BL

BL

BL

BL

BL

BK

BK

BK

BK

BK

BK

BK

BK

BK

R

R

R

R1

M6

M5

24V

AC

M2

M1

M4

M3

24V

AC

B1

50 A

A2

A1

R2

M2

M1

24V

AC

50 A

50 A

M4

M3

R3

M2

M1

24V

AC

BL

BL

K1 24V

1

5

2

3

6

4

24V

AC

BK

Recirculation

Mode

R

BK

BL

C

W

R

BK

M

K2 240V

1

5

2

3

6

4

240

VAC

NC

BK

BK

BK

BK

R

L1

L3

L2

G

HEAT 2

E

ARTP

R

HEAT 3

E

ARTP

R

HEAT 1

E

ARTP

R

BK

BK

BK

BK

BL

BL

BK

BK

R1

24V

AC

M2

M1

M4

M3

24V

AC

B1

50 A

M6

M5

B2

25 A

BL

1. If any of the original wire, as supplied, must 
be replaced, use the same equivalent wire. 
Wiring must comply with applicable codes, 
ordinances and regulations.

2. Field wiring must comply with applicable 
codes, ordinances and regulations. Use only 
Class 1 wiring inside furnace compartments.

Critical characteristic

Line voltage wiring:

UL AWM 1015, 600V, 105°C, VW-1, 8 AWG;  

CSA TEW 600V, 105°C, FT1, 8 AWG and 12 AWG.

Low voltage wiring: 
same ratings as high voltage except 18 AWG. 

HI

MED-HIGH

MED-LOW

LOW

FAN MOTOR SPEED

BLACK

BLUE

YELLOW

RED

COLOR

LEGEND

C

E

R

K

MRTP

HEAT

L1,
L2, L3

Capacitor

Heating Element

Time Delay Relay

Fan Relay 

Auto-Reset Thermal Protector

Manual-Reset Thermal Protector

Line Supply 208 V 3-Phase

WIRING COLOR CODE

 BK 

BLACK

 BL 

BLUE

 O 

ORANGE

 R 

RED

 W 

WHITE

 Y 

YELLOW

ARTP

M

TB

T

Fan Motor

Terminal Block

Transformer Class 2

Heat

B

Breaker

Low power
High power
High power 8 AWG

FE0071A

For the use of a two-stage thermostat or 
an outdoor thermostat, connect between 
W1 and W2.
Make sure that the Season Select switch 
is set to “Mild” position.

The wiring diagram for 27 kW model
is the same as the one for 24 kW model, 
except for the motor (illustrated at left).

50 A

25 A

R

BK

BK

R

BK

BK

BK

R

BK

R

Recirculation

Mode

B3

50 A

B2

50 A

50 A

R

R

R

BK

BK

BK

BK

BK

BK

BK

R

BK

BK

BK

BK

BK

R

UL AWM 1015/1230, 600V, 105°C, VW-1, 12 AWG;  

WARNING

Risk of electric shock. Disconnect power before installation, servicing, maintenance or field wiring. Replace all panels 
before operating. Failure to do so can result in electric shock causing severe injuries or death.

 83B1

Model

 83B24 

Model

 

83B27 
Model

Содержание 21B10M

Страница 1: ...N AND USER MANUAL IMPORTANT READ AND SAVE THESE INSTRUCTIONS MODELS 21B10M 21B15M 21B18M 21B20M 21B25M 21B27MS 83B13 83B24 AND 83B27 M A DE IN CANA D A F A B R I Q U AU CA N A D A NORTRON Sherbrooke Q...

Страница 2: ...ture furnace failure thus voiding the warranty Do not block the combustion air openings in the furnace Any blockage will result in improper overheat situation and may result in a fire hazard and or ca...

Страница 3: ...ERED FURNACE HUMIDIFIERS 7 7 4 INTERLOCK CONNECTION 7 8 WIRING DIAGRAMS 8 11 9 SERVICE PARTS 12 10 MAINTENANCE 13 11 TROUBLESHOOTING 13 12 WARRANTY 14 1 DIMENSIONS FK0004A FRONT VIEW RIGHT SIDE VIEW R...

Страница 4: ...x 203 mm 23 41 LOW 663 21B15M 15 51228 67 1 3 24 43 MED LOW 814 21B18M 18 61473 77 1 3 27 49 MED LOW 814 21B20M 20 68304 86 1 3 33 59 MED LOW 814 21B25M 25 85379 107 1 3 37 67 MED LOW 814 21B27MS 27...

Страница 5: ...s are turned on by the thermostat OFF The blower motor will operate in the standard heating mode controlled by the thermostat MILD During spring and fall you may not require full heating capacity to m...

Страница 6: ...of a floor opening 14 x 14 362 mm x 362 mm The duct system must be designed so that the external static pressure of the system does not exceed the maximum external static pressure of 0 50 W C 125 Pa S...

Страница 7: ...ummer directing all air flow through the coil In winter the damper would be open to allow air to bypass the coil Typical air conditioning field wiring connections are shown in the diagram at right FUR...

Страница 8: ...ing same ratings as high voltage except 18 AWG HI MED HIGH MED LOW LOW FAN MOTOR SPEED BLACK BLUE YELLOW RED COLOR LEGEND C E R K MRTP HEAT L1 L2 Capacitor Heating Element Time Delay Relay Fan Relay A...

Страница 9: ...he original wire as supplied must be replaced use the same equivalent wire Wiring must comply with applicable codes ordinances and regulations 2 Field wiring must comply with applicable codes ordinanc...

Страница 10: ...rdinances and regulations Use only Class 1 wiring inside furnace compartments Critical characteristic Line voltage wiring UL AWM 1015 600V 105 C VW 1 8 AWG CSA TEW 600V 105 C FT1 8 AWG and 12 AWG Low...

Страница 11: ...use the same equivalent wire Wiring must comply with applicable codes ordinances and regulations 2 Field wiring must comply with applicable codes ordinances and regulations Use only Class 1 wiring ins...

Страница 12: ...57 12 6 5 37 21 9 DQ 5HOD QRW LQ 0 9 DQ 5HOD 7UDQVIRUPHU 9 ORZHU KHHO PP PP IRU ORZHU 0RWRU 3 9 IRU 06 0RWRU 3 9 IRU 0 0 0 0 DQG 0 0RWRU 3 9 IRU 6HULHV OHPHQW VVHPEO 9 OHPHQW VVHPEO 9 OHPHQW VVHPEO 9...

Страница 13: ...N MODE switch open contact Bottom sequencer 4 Motor going on and off in short cycles or in too long cycles Heat anticipator in thermostat incorrectly set or may be defective 5 The thermostat must be s...

Отзывы: