Page 3
Ÿ
Use 1/8” hex wrench to close valves. Turn Clockwise. For
STANDARD CLOSER
, close valves ‘S/D’ and ‘L’.
DELAYED ACTION CLOSER
, close valves ‘S’ and ‘L’.
Ÿ
Set handing of “Arm Stop” on soffit plate. See illustration
on Page 1 for positions. If required, rotate stop. Secure with
1/4-20 x 5/16 machine screw.
Ÿ
With door closed, use wrench to rotate pinion shaft as
illustrated below.
Ÿ
Caution:
Closer arm is under spring tension and
may be difficult to rotate.
Start (wrench) here
Rotate
Install arm here
Ÿ
Place main arm on shaft,
aligning mark on arm with
pinion flat on pinion shaft; “Z” for Left Hand Door; “Y” for
Right Hand Door. Secure with 1/4-20 x 1/2 (13) with hex
head machine screw.
80-9377-0625-020 (03-13)
Ÿ
Reopen valves closed in Step 2. Turn Counterclockwise
Ÿ
With door closed, align soffit plate with mounting holes in
frame. Fasten soffit plate to frame with flat head screws
provided.
Ÿ
Adjust closer per instructions on page 4 before installing
cover.
CAUTION!
DO NOT BACK VALVES OUT OF
CLOSER OR A LEAK WILL RESULT
Ÿ
Install Cover:
Screw Standoffs into holes in closer.
Ÿ
Fasten cover to closer and cover bracket with 4 #8-32x1/4
round head screws provided.
Installation Sequence
Ÿ
Use template on page 2 to locate holes on door and frame:
4 on door for closer or drop plate.
5 on underside of frame stop for soffit plate.
Ÿ
Prepare door and frame for fasteners using chart on page
2.
Ÿ
Mount closer on door.
(A drop plate is available for use on
doors having narrow top rails)
Power Adjustment Nut
should be away from hinge. Valves are
DOWN
for
Left
Hand Door
. Valves are
UP
for
Right Hand Door
.
Left Hand Door
Flat
Right Hand Door
Flat
Main Arm Screw