background image

3. Always unplug heater when not in use. 
4. Do not operate any heater with a damaged cord or plug or after 
heater malfunctions, has been dropped or damaged in any way.     
5. Do not use outdoors. 
6. This heater is not intended for use in bathrooms, laundry areas 
and  similar  indoor  locations.  Never  locate  heater  where  it  may 
fall into a bathtub or other water container. 
7. Do not run cord under carpeting. Do not cover cord with throw 
rugs, runners or the like. Arrange cord away from traffic area and 
where it will not be tripped over.   
8. To disconnect heater, turn controls to "OFF" before removing 
plug from outlet. 
9. Do not insert or allow foreign objects to enter any ventilation 
or exhaust opening as this may cause an electric shock or fire or 
damage the heater. 
10.  To  prevent  possible  fire,  do  not  block  air  intakes  in  any 
manner. 
11.  Use  this  heater  only  as  described  in  this  manual.  Any  other 
use is not recommended by the manufacturer which may cause 
fire, electric shock or injury to people and/or animals. 
12. Always use properly grounded fused and polarized outlets. 
13.Always  use  ground  fault  protection  where  required  by 
electrical codes. 
14.  Always  disconnect  power  before  performing  any  cleaning, 
maintenance or relocation of heater. 
15. Always plug heaters directly into a wall outlet/receptacle. 
Never use with an extension cord or relocatable power tap 
(outlet/power strip). 
16.  To  prevent  a  possible  fire,  do  not  burn  wood  or  other 
materials in this heater. 
17.  To  prevent  electric  shock  or  fire,  always  use  a  certified 
electrician should new circuits or outlets be required. 
18. When transporting or storing heater, keep in a dry place free 

from excessive vibration and damage. 
19. The heater must not cover up an electrical socket; the socket 
must always be accessible in order to disconnect the heater from 
the electrical supply for maintenance and cleaning. 
20. This heater must be grounded.    The main supply must be   
Safely routed from the heater to an electrical socket

.

 

Note:  When  the  heater  is  turned  on  for  the  first  time,  it  may 
release a slight, harmless odor or smoke. This odor or smoke is a 
normal  occurrence  caused  by  the  initial  heating  of  the  internal 
heating elements and should not occur again. 

 

SAVE THESE INSTRUCTIONS 

Technical Specification 

Description of product 

ELECTRIC FIREPLACE 

 

Model 

80-2000A-36,80-2000A-42,80-2000A-54 

Rated Voltage 

120V~ 

Rated Frequency 

60 Hz 

Rated Power 

1500W 

Lamp 

LED 

 

Unpacking and Testing   

1.  Carefully remove the unit from the box. Prior to using the unit, 

test to make sure the unit operates properly. Plug the unit's   

power  supply  cord  into  a  conveniently  located  120volt 

grounded   

Содержание 80-2000A-36

Страница 1: ...NG All electric heaters have hot inside Do not use it in areas where gasoline paint or flammable liquids vapors are or are stored Retain this manual for future reference CAUTION Do not expose the heater to the elements such as rain etc CAUTION The fireplace in Due to high temperatures the heater should be located out of traffic and away from furniture and draperies Do not place clothing or other f...

Страница 2: ... or relocation of heater 15 Always plug heaters directly into a wall outlet receptacle Never use with an extension cord or relocatable power tap outlet power strip 16 To prevent a possible fire do not burn wood or other materials in this heater 17 To prevent electric shock or fire always use a certified electrician should new circuits or outlets be required 18 When transporting or storing heater k...

Страница 3: ...re Part Quantity Remote Control 1 Manual 1 Fixing Hanger In the back of the fire 1 Fixing Bracket 1 Crystals 1or 2 80 2000A 54 Screw ST4 8 1 Screw ST4 40 5 Plastic expansion 5 Tool required Magnetic Phillips Screw Driver WARNING Do not operate the unit if it is damaged or has malfunctioned If you suspect the unit is damaged please contact customer service The appliance is employed a manually reset...

Страница 4: ...1 Put the fireplace on flat floor with the front glass panel on top position 2 Use screwdriver not supplied to loosen the 7or 9 screws as Fig A and remove the glass panel 3 Put the craystals gently on the ember as Fig B 4 Tighten the glass panel with the 7 or 9 screws tightly 5 Use screwdriver not supplied to loosen the 2 screws as Fig C and remove the hanger Fig A Fig B Fig C ...

Страница 5: ...g pipe wires etc in the area to be drilled Drill 4 holes 8mm diameter 40mm depth using a suitable size drill and put the Plastic expansion into the holes 4 First fix hanger to wall 5 Referring to Fig 4 hang fireplace to hanger 6 Referring to Fig 5 avoid fireplace to move use screw fix fireplace to wall Warning Always ensure the fireplace is at least 200mm above the floor Be sure that the bolts hav...

Страница 6: ...FF Turn on the fireplace the Power LED will be lighten 2 Heat control button Push the HEAT button to cycle through as bellow HIGH heater work with 1500W HEATER LED for RED LOW heater work with 750W HEATER LED for Blue TEMP HEATER LED for Purple Adjusting to auto control by room temperature the heater turns on and work with 1500W when room temperature is below 22 C the heater turns on and work with...

Страница 7: ...d ember bed To increase the brightness press and release the button Each time you press this button the brightness will increase by a small amount until the maximum is reached To decrease the brightness press and release the button Each time you press this button the brightness will decrease by small amount until the minimum brightness is reached 6 The BLUE buttons control the blue brightness of f...

Страница 8: ...ove has overheated and safety device has caused thermal switch to disconnect or home circuit breaker has opened Reset switch by turning main power switch off and waiting 5 minutes then turning it back on Flame is not moving Flame motor defective Call a qualified service technician to replace flame motor Flame sputters Flame motor is defective Call a qualified service technician to replace flame mo...

Отзывы: