background image

NorthStar SLIM Tach

®

 HS56 Instruction Manual 

                                        5 May 1999 

 

CHAPTER 1 

INTRODUCTION

  

1.0  Safety Summary

 

 

High current, voltage, and rotating parts can cause serious or fatal injury. The use of electric machinery, like all other uses of 

concentrated power and rotating equipment, may be hazardous. Installing, operating, and maintaining electric machinery 

should be performed by qualified personnel, in accordance with applicable provisions of the National Electrical Code and 

sound local practices. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates 

safety standards of design, manufacture, and intended use of the instrument. NorthStar Technologies, Inc. assumes no liability 

for the customer's failure to comply with these requirements. 

 

Rotating Machinery 

Avoid contact with rotating parts. Avoid by-passing or rendering inoperative any safety guards or protection devices. Avoid 

extended exposure in close proximity to machinery with high noise levels. Use proper care and procedures in handling, lifting, 

installing, operating and maintaining the equipment. 

 

Before Installation 

Safe maintenance practices with qualified personnel is imperative. Before starting maintenance procedures, be positive that, 

(1) equipment connected to the shaft will not cause mechanical rotation, (2) main machine windings have been disconnected 

and secured from all electrical power sources, and (3) all accessory devices associates with the work area have been de-

energized. If high potential insulation test is required, follow procedures and precautions outlined in NEMA standards MG-1. 

 

Grounding 

Improperly grounding the frame of the machine can cause serious or fatal injury to personnel. Grounding of the machine 

frame and structure should comply with the National Electrical Code and with sound local practices. Check wiring diagram 

before connecting power. 

 

Do Not Operate In An Explosive Atmosphere 

Do not operate the instrument in the presence of flammable gases or fumes. Operating any electrical instrument in such an 

environment constitutes a definite safety hazard. 

 

Keep Away From Live Circuits 

Operating personnel must not remove instrument covers. Component replacement and internal adjustments must be made by 

qualified maintenance personnel. Do not replace components with power cable connected. To avoid injuries, always 

disconnect power and discharge circuits before touching them. 

 

Do Not Substitute Parts Or Modify Instrument 

Do not install substitute parts or perform any unauthorized modification to the instrument. Introducing additional hazards is 

dangerous. Return the instrument to an authorized NorthStar Technologies, Inc. representative for service and repair to ensure 

that safety features are maintained. 

 

Dangerous Procedure Cautions 

A CAUTION heading precedes potentially dangerous procedures throughout this manual. Instructions in the warnings 

must

 

be followed. 

Содержание SLIM Tach HS56

Страница 1: ... NorthStar Technoogies Inc 791 1010 00 Rev C 5 May 1999 Instruction Manual SLIM Tach HS56 Magnetoresistive Encoder Designed for use in 0 625 1 125 16mm 30mm Hollow Shaft Applications ...

Страница 2: ... conjunction with the Customer that the product is required to be returned to NorthStar s factory for warranty repair a Return Goods Authorization RGA number will be issued For control purposes only those items identified with an RGA number may be returned to NorthStar Please make sure that the RGA number is clearly marked on the shipping label Packages missing an RGA number cannot be accepted by ...

Страница 3: ... Hood Wiring 9 Figure 5 Sealed Industrial Latching Connector 10 2 4 Returning Equipment to NorthStar 10 Methods and apparatus disclosed and described herein have been developed solely on company funds of NorthStar Technologies Inc No government or other contractual support or relationship whatsoever has existed which in any way affects or mitigates proprietary rights of NorthStar Technologies Inc ...

Страница 4: ...nnected and secured from all electrical power sources and 3 all accessory devices associates with the work area have been de energized If high potential insulation test is required follow procedures and precautions outlined in NEMA standards MG 1 Grounding Improperly grounding the frame of the machine can cause serious or fatal injury to personnel Grounding of the machine frame and structure shoul...

Страница 5: ...already done for you in the encoder The anti rotation arm is very forgiving to any axial or radial motions that the motor might have yet is very torsionally non compliant Similar to NorthStar s heavy duty and mill duty encoders the SLIM Tach HS56 contains patented magneto resistive technology Magnetoresistive technology allows the NorthStar HS56 to be placed in the toughest environments The unit i...

Страница 6: ...rrent Capability 150 mA typical 350 mA maximum worst case Connector 10 pin Epic style NEMA 4 12 industrial connector Suggested Cable 22 AWG 8 Conductor 18 length 4 twisted shield pairs Input Voltage 5 0 to 15 0 VDC Mechanical Specifications Maximum Operational Speed 3 600 RPM Shaft Requirements 0 625 1 125 0 000 0 0005 Bearings Sealed Max Radial Runout 0 015 total indicated run out Max Axial Trave...

Страница 7: ...tages advise NorthStar immediately NorthStar cannot be responsible for any missing parts unless notified within 60 days of shipment The standard NorthStar Technologies Inc warranty is included on page 2 of this manual 2 1 Mounting the HS56 to a NEMA 180 or 56 C Face Motor 1 When the HS56 is to be mounted onto a motor with opposite end NEMA C Face insert the appropriate bolt i e 3 8 16 UNC or 13 UN...

Страница 8: ...er the bolt tighten the hex standoff 4 Insert anti rotation rod end into the Hex standoff and tighten CAUTION The anchor bolt is designed for minimum inch of clearance between the fan and the fan shroud If there is not clearance the fan may hit the anchor bolt head on the inside of the fan shroud See drawing below The minimum shaft length for fan shroud mounting is 2 65 5 Slide the HS56 onto the a...

Страница 9: ... pulse capability Pinouts are for the sensors with the MS 3102E18IT connector NOTE The shield in the sensor module is isolated from the frame of the encoder For maximum noise immunity the shield wire or pin should be connected to the shield of the cable and that of the drive or other receiving device 2 3 1 Quick Release Connector Hood Wiring To install the Quick Release Connector perform the follo...

Страница 10: ...r must be obtained from a factory representative before returning the equipment to our service department When returning an instrument for service the following information must be provided before NorthStar can attempt any repair 1 Instrument model and serial number 2 User s name company address and phone number 3 Malfunction symptoms 4 Description of system 5 Returned Goods Authorization number C...

Страница 11: ...NorthStar SLIM Tach HS56 Instruction Manual 11 5 May 1999 ...

Отзывы: