21
Northstar
Explorer AP380 System
Installation and Operation Manual
Installation
1
Find a suitable location for the unit as described above.
2
Mount the unit with the three screws provided. Use a level to ensure the unit is vertical to within 10°.
Less than
10° 10°
3
Wire the cable back to the MCU600, following the wiring guide (see section 3-2-2).
Less than 10° 10°
MCU600
Plug connector into the Compass/HS socket
Holes in the bulkheads must
be at least 18.5 mm (0.73 in)
diameter.
Note
If you move the compass with respect to
the gyro while the power is on, wait for the
heading to stabilize.