Operation (cont’d)
28
6. Stopping
Stop the generator using the following steps:
1.
Disconnect all loads to generator. (Never reduce throttle with electrical loads connected.
Damage to generator and loads will occur.)
2.
After all loads are disconnected, slowly reduce PTO speed to a minimum and then disengage
PTO.
3.
Shut OFF the tractor engine.
4.
Remove the PTO driveline shaft from generator and tractor.
7. Storage & Exercise
When you are finished using the generator, you must:
o
Disconnect all loads and PTO driveline
o
Store the generator properly
o
Plan on exercising the engine regularly
Detailed instructions are provided below.
Disconnect loads &
PTO
When you are finished using the generator:
1.
Make sure all loads are disconnected from generator’s outlets.
2.
Make sure the generator is disconnected from the PTO.
Store in
appropriate
location
1.
Let generator cool for at least five minutes before storing.
Hot
equipment can be a fire hazard near combustible materials.
2.
Store the generator in a location that is:
o
Clean and dry. It is important to keep the generator windings free of
moisture.
o
Away from extreme high or low temperatures.
Exercise generator
every 4 weeks
The generator should be exercised regularly.
At least every four weeks, start the generator and let it run for 10 to 15
minutes.
Monthly exercising of the generator will:
o
Dry out any moisture that has accumulated in the windings. If left,
this moisture can cause corrosion in the winding.
o
Ensure that the unit is operating properly should it be needed in an
emergency.
Perform regular
maintenance
Perform periodic maintenance
as directed in this manual to keep the
generator in safe working condition.