![NorthStar 165165 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/northstar/165165/165165_product-manual_1708905009.webp)
Machine Component Identification - Item #165165A
9
REFERENCE GUIDE
Reference 1
– Main Line Breaker
The main line breaker is a two-pole thermo-magnetic circuit breaker.
The circuit breaker will protect the generator from overload and short
circuit conditions. To reset the circuit breaker move the toggle to the
OFF position, then back to the ON position. When this circuit breaker
is in the OFF position, all receptacles will be off.
Reference 2
– Thermal Circuit Breakers
The control panel has two thermal circuit breakers. If the circuit breaker
trips, a black post will extend from the circuit breaker, push the black
post to reset the circuit breaker. If the circuit breaker will not reset, wait
two minutes and try again.
Reference 3
– Voltmeter
The voltmeter allows for monitoring of the generator. The needle
should be in the green area for all load conditions.
Reference 4
– 120 Volt-20 Amp GFCI
Duplex Receptacles
The control panel is equipped with four 120 Volt-20 Amp ground fault
circuit interrupt (GFCI) receptacles (NEMA 5-20R). The receptacles
will accept either NEMA 5-15P or NEMA 5-20P plugs. In the center of
each duplex receptacle there is both a test/reset button and indicator
lamp. If there is a fault condition with a load connected to a duplex
receptacle, the indicator lamp will glow and the reset button will extend.
To test the GFCI press the test button and the reset button should
extend. The reset button must be pushed to reset the receptacle.
Reference 5
– Hour Meter
The hour meter allows for monitoring of engine maintenance
schedules.
Reference 6 - Engine Stop Lever
The engine is stopped by pushing and holding the engine stop lever.
Turning the engine key to the OFF position will not stop the engine.
Reference 7
– 120 Volt-30 Amp Locking
Receptacle
The control panel is equipped with one NEMA L5-30R receptacle. This
receptacle accepts only NEMA L5-30P plugs.
Reference 8
– Engine Starting Key
To start the engine, turn the key to the START position.
Reference 9
– 120/240 Volt-30 Amp
Locking Receptacle
The control panel is equipped with one NEMA L14-30R receptacle.
This receptacle accepts only NEMA L14-30P plugs. This receptacle is
popular for connection to a transfer switch for home standby power.
Reference 10
– Oil Drain Plug
Removal of plug allows drainage of oil from the engine. Consult your
Kubota engine manual for further details.
Reference 11
– Oil Fill and Dip Stick
Consult your Kubota
engine owner’s manual for details concerning oil
change intervals.
Reference 12
– Air Cleaner Housing
Refer to the Kubota engine manual for air cleaner care.
Reference 13
– Decompression Lever
Reduces the load on the engine during starting for a smoother start.
Reference 14
– Muffler
Muffler can be very hot during operation and will burn you.
Reference 15
– Ignition Fuse
Your engine is equipped with a 30 Amp fuse located on the wire
harness below the generator head.
Reference 16
– Isolation Mounts
The engine and generator are mounted on rubber mounts that absorb
most of the engine vibration. This feature eliminates the tendency of
the machine to “walk” which is common with engine powered
equipment.
Reference 17
– Battery Box
The battery box provides protection for the battery and will accept a
standard lawn tractor size battery (Group U1-7). The engine requires a
12 volt battery, with a minimum rating of 36 Ah (Amp-hour). See
battery section for sizing.
Reference 18
– Generator Head
Your NorthStar product is equipped with a high quality brushless
generator. The generator is maintenance free and will provide years of
dependable service.
Reference 19
– 6.5 Gallon Fuel Tank
Large tank allows for extended run capabilities.
Always
allow room for
fuel expansion by not filling the tank completely full.
Reference 20
– Fuel Cap with Gauge
The fuel cap is extra large, creating a large hole for refilling and a
comfortable grip.
You can always monitor the fuel level without
removing the cap by using the fuel level indicator built into the fuel cap.