chips or debris. 

EXTENSION CORDS

Improper use of extension cords may cause inefficient operation
of  the  log  splitter  which  can  result  in  overheating.  Be  sure  the
extension cord is no longer than 10m and its section is no less
than 98" 

to allow sufficient current flow to the motor.

Avoid  use  of  free  and  inadequately  insulated  connections.
Connections must be made with protected material suitable for
outdoor use.

AVOID ELECTRICAL SHOCK

Check that the electric circuit is adequately protected and that it
corresponds with the power, voltage and frequency of the motor.
Check  that  there  is  a  ground  connection,  and  a  regulation
differential switch upstream.
Ground  the  log  splitter.  Prevent  body  contact  with  grounded
surfaces: pipes, radiators, ranges, and refrigerator enclosures.
Never  open  the  push  button  box  on  the  motor.  Should  this  be
necessary,  contact  a  qualified  electrician.  Make  sure  your

fingers  do  not  touch  the  plug

s  metal  prongs  when  plugging  or

unplugging the log splitter.

KEEP VISITORS AND CHILDREN AWAY

The  log  splitter  must  be  always  operated  by  one  person  only.
Other  people  should  keep  a  safe  distance  from  the  work  area,
especially  when  the  log  splitter  is  under  operations.  Never  use
another person to help you with freeing jammed log.

INSPECT YOUR LOG

Make sure there are no nails or foreign objects in logs to be split.
The ends of the logs must be cut square. Branches must be cut
of flush with the trunk.

DON

’T OVERREACH

Floor must not be slippery. 
Keep proper footing and balance at all times. 
Never stand on log splitter. Serious injury could occur if the tool is 
tipped or if the cutting tools is unintentionally contacted. Do not 
store anything above or near the log splitter where anyone might 
stand on the tool to reach them. 

AVOID INJURY FROM UNEXPECTED ACCIDENT

Always pay full attention to the movement of the log pusher.
Do not attempt to load the log on until the log pusher has
stopped.
Keep hands out of the way of all moving parts.

Содержание HY4T-370

Страница 1: ...RSTAND THE ENTIRE MANUAL BEFORE OPERATING MACHINE MODEL NUMBER HY4T 370 SERIAL NUMBER Both model number and serial number may be found on the main label You should record both of them in a safe place...

Страница 2: ...t use it in areas where fumes from paint solvents or flammable liquids pose a potential hazard INSPECT YOUR LOG SPLITTER Check your log splitter before turning it on Keep guards in place and in workin...

Страница 3: ...a qualified electrician Make sure your fingers do not touch the plug s metal prongs when plugging or unplugging the log splitter KEEP VISITORS AND CHILDREN AWAY The log splitter must be always operat...

Страница 4: ...ing adjustments changing parts cleaning or working on the log splitter Consult technical manual before servicing PROTECT THE ENVIRONMENT Take used oil to an authorized collection point or follow the s...

Страница 5: ...W IP54 S6 40 Log Capacity Diameter 1 96 10 Length 15 Splitting Force 4T Hydraulic fluid capacity 1 8L Packing Size 32 6 11 22 18 11 G W N W LB 90 85 The diameter of the log is indicative a small log c...

Страница 6: ...Y 11 Hydraulic Control Lever 12 Control Lever Guard 13 Bleed Screw 14 Oil Drain Bolt w Dipstick Before operating the log splitter the Bleed Screw should be loosened by a few rotations until air can go...

Страница 7: ...d the max pressure limiting screw is sealed with glue to ensure the log splitter works under pressure no more than 7 tons The setting was done by qualified mechanic with professional instruments Unaut...

Страница 8: ...d with the index finger before push the Hydraulic Control Lever forward Never force the log splitter for more than 5 seconds by keeping pressure on it to split excessively hard wood After this time in...

Страница 9: ...hem may fly up and hit you FREEING A JAMMED LOG Release both controls After the log pusher moves back and completely stops at its starting position insert a wedge wood under the jammed log Start the l...

Страница 10: ...plitter on the motor side Refill fresh hydraulic oil at the volume as per the hydraulic oil capacity of a particular model indicated in above specifications table Clean the surface of Dipstick on the...

Страница 11: ...or hardness of the log exceeds the capacity of themachine Reduce the log sizes before splitting it on the log splitter Wedge cutting edge is blunt Refer to Sharpening Wedge section to sharpen the cutt...

Страница 12: ...NLE5WZ_LS56 www northlineexpress com 1 866 667 8454 12...

Страница 13: ...lumn head bolt M8X10 6 Piston rod 25 Stop ring 6 7 Nuts M14 26 Small Spring 7 8 8 Lift handle 27 Small spindle 9 Inner hexagon bolt M6X16 28 Gasket 55X3 1 10 Washer 14 29 O ring 10 6X1 8 11 Anti loose...

Страница 14: ...8 45 Oil ruler 65 Nut 6 46 Support Protection guard 66 Inner six angle bolt M6X30 47 Inner hexagon bolt M6X10 67 Framework oil seal 48 Red plastic cover 68 Motor spindle 49 Wheel 69 Motor 50 Spindle...

Страница 15: ...NLE5WZ_LS56 www northlineexpress com 1 866 667 8454 15...

Отзывы: