FLOOR
PROTECTOR
DASHED LINES SHOW HORIZONTAL CHIMNEY CONNECTOR
AND ADDITIONAL FLOOR PROTECTOR REQUIRED BENEATH
AND EXTENDING 2” BEYOND EACH SIDE
COMBUSTIBLE CONSTRUCTION PER NFPA 211
BACKWALL
SIDEWALL
31"
4 8"
16"min.
6"min.
17"
22"
min.
11"min.
TOP VIEW
29"
TR008
CAUTION: FAILURE TO FOLLOW THESE
M I N I M U M C L E A R A N C E R E Q U I R E -
MENTS MAY RESULT IN AN UNSAFE
INSTALLATION AND COULD CAUSE A FIRE.
8. T h i s s t ove m e e t s U. S. Te s t S t a n d a r d :
UL 1482-2006.
9. Always locate stove to provide a source of fresh
air into the room where the unit is installed.
Failure to do so may result in air starvation of other
fuel burning appliances and the possible develop-
ment of hazardous conditions.
NOTE: ANY WALL CONTAINING COMBUSTI-
BLE MATERIAL SUCH AS WOODEN STUDS OR
DRYWALL AND FACED WITH BRICK OR STONE
MUST BE CONSIDERED A COMBUSTIBLE
SURFACE.
6.
DO NOT INSTALL THIS STOVE IN A MOBILE
HOME, MANUFACTURED HOME, TRAILER
OR TENT – NO EXCEPTIONS! (HUD Federal
Standard: 24 CFR Ch.XX)
7. T h e c l e a ra n c e s p r ov i d e d a r e m i n i mu m
dimensions determined by OMNI-Test Lab-
oratories, Inc., the manufacturer’s testing
laboratory. Installation of this stove must
comply with the latest edition of NFPA 211 for
reduced clearances and/or your local build-
ing code rulings. Use whichever minimum
dimensions are LARGEST.
Fig. 5 – Top View Minimum Clearance Dimensions from
Combustible Surfaces
13"
13"
CORNER CLEARANCES
Fig. 6 – Minimum Corner Clearance
Dimension from Combustible Surfaces
Fig. 7 – Front & Side Views: Minimum Clearance Dimensions
from Combustible Surfaces
CAUTION: KEEP FURNISHINGS AND
OTHER COMBUSTIBLE MATERIALS
AWAY FORM THE STOVE AND OUTSIDE
MINIMUM CLEARANCES.
LOCATING STOVE continued…
Call us at 1-866-667-8454