4
3625 Cincinna
ti
Avenue, Rocklin CA 95765
● 855
-3
88
-7422
●
◆
Appli
cati
on Diagram 3:
Single Camera w/ External Power Supply EoC Transmission System
(No PoE)
Before star
ting
the pairing process, please check the no
ti
ce below
1)
If only setup one transmission system at NVR or control room side there is
no need to do pairing
process.
2)
When using two or more transmission systems at the NVR or Control room – if there is no cross-talk
between the two systems then there is no need to perform the pairing process.
EoC Transmission System Network Group Pairing Instruc
ti
ons
Step 1: Setup EoC Transmission System
♦
Connect all the coaxial, cat. 5e cables between transceivers, setup cameras and NVR then power
supplied to the system that one of the applica
ti
on diagrams.
Step 2: Host/Master Side Leaving Current Network Group
♦
On the transceiver at NVR side, using a straightened paper-clip
push the small bu
tt
on for
5 ~ 8 seconds
, the LED color will
turn
AMBER
blink once then turn
OFF
.
Step 3: Host/Master Side Create an New Network Group
♦
On the transceiver at NVR side, using a straightened paper-clip to push the small bu
tt
on for
1 ~ 3
seconds
, the LED color will turn
RED
and start blinking.
Step 4: Slave Side Transceiver Leaving Current Network Group
♦
On the transceiver at the Remote side (close to IP camera/device), using a straightened paper-clip to
push the small bu
tt
on for
5 ~ 8 seconds
, the LED color will turn
AMBER
blink once then turn
OFF
.
Step 5: Slave Side Transceiver Joining New Network Group
♦
EOC transceivers at Remote side (close to IP camera/device, using a straightened paper-clip to
push the small bu
tt
on for
1 ~ 3 seconds
, the LED color will begin blinking
RED
. The transceivers will
fi
nd each other and star
ti
ng the transmission.
In Pairing Process No
ti
ce
1)
In joining or leaving process, if you are not sure that joining or leaving has been successful, you can
RESET the transceiver (press the push bu
tt
on 12 to 30 seconds) , and repeat above steps.
2)
A
ft
er re-applying power or RESETING the transceiver, please wait for the color LED to start blinking
Amber once then turn GREEN, this means the power on reset
fi
nished and you can now start the
pairing process.
3)
If the transceiver is in LEAVE to JOIN state (color LED blinking RED), it must join new network group
within 2 minutes
or it
will
revert
to a LEAVE state again.
Monitor
DC 56V/65W
Max 2000m (RG6)
NVR
Switch
IP Camera
P
P
Etherne
t Over Coaxial Transce
iver with PoE
Ethernet Over Coaxial Transceiver with PoE