![Northern Telecom DMS-100 Series Скачать руководство пользователя страница 48](http://html.mh-extra.com/html/northern-telecom/dms-100-series/dms-100-series_maintenance-manual_1708607048.webp)
5-4 List of terms
297-2101-504 Standard 02.01 December 1991
PCM30 line drawer (PLD)
The PLD is an integral part of the host or remote line concentrating module,
which interfaces with multiplexers at customer sites. The interface consists
of two PCM30 links, and each link is capable of carrying a maximum of 30
digital exchange lines.
PCM30 line group controller (PLGC)
See Line group controller
PCM30 remote line concentrating module (PRLCM)
See Remote line concentrating module
Peripheral module (PM)
PM is a generic term referring to all hardware modules in DMS-100 Family
systems. PMs interface with external line, trunk, or service facilities. PMs
contain peripheral processors, which perform local routines, to relieve the
load on the central processing unit.
Pulse code modulation (PCM)
PCM represents an analog wave form by coding and quantifying periodic
samples of the signal, so that each element of information consists of a
binary number that represents the value of the sample.
Remote line concentrating module (RLCM)
An RLCM is an equipment frame that interfaces a maximum of 600 digital
exchange lines or 640 analog lines with the line group controller. An RLCM
consists of a line concentrating module, a remote maintenance module, a
host interface equipment shelf, and a frame supervisory panel.
Service order and query system (SERVORD)
The service order and query system (SERVORD) is a user interface that
changes, adds, or deletes a subscriber line using standard telephone industry
command format.