Northern Lights TECHNICOLD OM-NI Скачать руководство пользователя страница 7

OM-NI 2/20

6

Pump size. 4.13”L x 4.87”W x 6.11”H (104.9mm x 123.7mm x 155.2mm).

• 

Pump NPT sizes. Outlet. 1/4-18 MPT   Inlet. 3/4-14 MPT or 3/8-18 FPT.

 

• 

Transport hose. 0.75” ID/ 1.25” OD.

• 

The entire front of the unit must be kept clear of obstructions to allow removal.

• 

Provide a minimum of 12” (30.5cm) clearance around and above the machine for installation and service.

Introduction 

  4.5in

114mm

 

  4.75in

121mm

 

 

1.81in 46mm

 

3/8"-18 

NPT INLET

  1.28in

32mm

 

  3.5in

89mm

 

 

4.13in 105mm

 

3/4"-14

NPT INLET

1/4"-18

NPT OUTLET

 

6.05in 154mm

 

  1.88in

48mm

 

  2.72in

69mm

 

MTG.

QTY 4

0.20in

5mm

SIDE

MTG.

3.25in

83mm

MTG.

3.88in

98mm

MTG. 0.50in 13mm

 

0.69in 17mm

 

 

1.19in 30mm

 

BOTTOM

FRONT

TOP

4

A

1

2

3

B

B

A

2

1

3

4

0

DO NOT SCALE DRAWING

2/10/2020

MCE

UNLESS OTHERWISE SPECIFIED:

SCALE: 1:2

REV

DWG.  NO.

B

SIZE

TITLE:

NAME

DATE

COMMENTS:

Q.A.

MFG APPR.

ENG APPR.

CHECKED

DRAWN

FINISH

MATERIAL

INTERPRET GEOMETRIC

TOLERANCING PER:

DIMENSIONS ARE IN INCHES

TOLERANCES:

FRACTIONAL

ANGULAR: MACH      BEND 

TWO PLACE DECIMAL    

THREE PLACE DECIMAL  

APPLICATION

USED ON

NEXT ASSY

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS

DRAWING IS THE SOLE PROPERTY OF

TECHNICOLD.  ANY REPRODUCTION IN 

PART OR AS A WHOLE WITHOUT THE 

WRITTEN PERMISSION OF TECHNICOLD IS 

PROHIBITED.

M90853

WEIGHT: 

1419 W NEWPORT CENTER DRIVE

DEERFIELD BEACH, FL 33442

1-800-843-6140

TEL: (954)-421-1717

FAX:(954)-421-1712

TE250 CENTRIFUGAL 

WATER PUMP 5 GPM 

115VAC 

Fig. 2- dimensions w/pump

Содержание TECHNICOLD OM-NI

Страница 1: ...OPERATOR S MANUAL OPERATOR S MANUAL OM NI For Northern Ice www technicold com...

Страница 2: ...rfield Beach FL 33442 Tel 954 421 1717 Fax 954 421 1712 Copyright 2020 Northern Lights Inc All rights reserved Northern Lights Technicold the Northern Lights logo and the Technicold logo are trademark...

Страница 3: ...RULES 7 8 INSTALLATION 9 13 PRE COMMISSIONING CHECKS 14 COMMISSIONING 14 DISPLAY SCREEN 15 TROUBLESHOOTING 16 MAINTENANCE 17 19 MAINTENANCE LOG 20 WIRING DIAGRAMS 21 WARRANTY 22 Table of Contents Pro...

Страница 4: ...r sign your delivery receipt Damaged Notify Northern Lights Inc immediately that the shipment is dam aged Take detailed photos of the damage with the original packaging for the freight claim Shipping...

Страница 5: ...water passes through the coil and draws heat out of the refrigerant circuit the heated water is then discharged overboard ATE250pumpwillsufficeformostapplications It is recommended that the ice machi...

Страница 6: ...ression adapter available 2 x FPT Drain pan condensate connections OD Condenser coil inlet OD Condenser coil outlet Weights Unit 124 lbs 56 25 kg Pump 115V 5 10 lbs 2 31 kg Pump 230V 5 20 lbs 2 35 kg...

Страница 7: ...13mm 0 69in 17mm 1 19in 30mm BOTTOM FRONT TOP 4 A 1 2 3 B B A 2 1 3 4 0 DO NOT SCALE DRAWING 2 10 2020 MCE UNLESS OTHERWISE SPECIFIED SCALE 1 2 REV DWG NO B SIZE TITLE NAME DATE COMMENTS Q A MFG APPR...

Страница 8: ...ols and Instructions In addition to the information found in this section this operator s manual uses three different signal words to outline potential dangers of a specific nature Follow All Safety I...

Страница 9: ...erant The system contains high pressure refrigerant R404a The refrigerant circuit can only be serviced by EPA608 certified technicians or equivalent Refrigerants should be handled using safe handling...

Страница 10: ...the unit carried by the top of the frame To remove the top cover use a flat head screwdriver to turn the latches 180 degrees counter clock wise Check that you have all the parts needed for the instal...

Страница 11: ...DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL ANGULAR MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL APPLICATION USED ON NEXT ASSY PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRA...

Страница 12: ...ined with the weight of the hose can stress the pump outlet connection Any type of impact on the hose can also stress the connection Support the hose within 18 46cm of the pump outlet Insulate the ice...

Страница 13: ...al start up Install the end of the outlet delivery hose as high as pos sible in the ice bin PREFERRED ROUTING UPHILL ACCEPTABLE ROUTING HIGH SPOT ACCEPTABLE ROUTING DIP ICE BOX ICE BOX ICE BOX A A B B...

Страница 14: ...f the unit The power supply raw water pump and ice bin sensor can be routed through these penetrations For ease of installation we provide a wiring harness with heat shrink butt connectors for the pum...

Страница 15: ...n the circuit breaker in the ship s panel Turn on the on off breaker on the outside of the ice machine s electrical box Allow time for the digital display to power up Once powered up and the main scre...

Страница 16: ...s the system shuts down and the Alarm indicator illuminates A fault description is displayed at the bottom of the screen Pressing the Status button to the left will take you to the Status screen The F...

Страница 17: ...triction Suction Pressure Suction pressure low Check ice delivery hose for blockage INDICATIONS DESCRIPTION Compressor Compressor running Auger Auger running Raw Water Pump Pump running Water Valve So...

Страница 18: ...bles in the pump head can cause cavitations that erode the impeller and pump head on metal pumps It can also damage the shaft seal It causes binding of the impeller on plastic head pumps Check bonding...

Страница 19: ...nd or Local Regulations Maintenance Follow all directions and warnings provided by the manu facturer of the chemical Safety equipment and clothing must be used to protect personnel and prevent damage...

Страница 20: ...esh water for a mini mum of 10 minutes to remove residual chemical Every chemical manufacturer provides dilution ratios and gallons of chemical required for the size system that you have They also hav...

Страница 21: ...OM NI 2 20 20 Maintenance Log Date NOTES TASK...

Страница 22: ...BL PUMP BK WH BK WH WH BK RD BK HMI DC PWR PLUG P2 1 P2 2 P1 2 P1 1 P5 1 P5 2 P6 3 P6 1 P7 1 P7 2 P3 1 P3 2 P8 1 P8 2 P8 3 P4 1 P4 2 GN GN GN GN GN TO LID GND POST P6 2 GN RD RD RD AUGER O P LP I P S...

Страница 23: ...WARRANTY LIMITATIONS This warranty will not apply to equipment put into service more than twenty four 24 months from date of shipment from factory and will not apply in any country with which trade is...

Страница 24: ...OM NI 2 20 23 Notes Date...

Страница 25: ...OM NI 2 20 24...

Страница 26: ...thern Lights 1419 W Newport Center Drive Deerfield Beach FL 33442 Tel 954 421 1717 www technicold com Northern Lights and Technicold are registered trademarks of Northern Lights Inc 2020 All rights re...

Отзывы: