background image

Performance Data and Specifications

L1276A2

Notes: 

1. Max. cruise rpm for High Output and Medium Duty ratings is1900 or 200 rpm below highest attainable rpm-

whichever is lower. 

Curves:

 

A.

 Maximum torque at flywheel. 

B. 

Flywheel power. Prop shaft power is 3-3.5% lower due to marine reduction 

gear power loss.  

C.

 Theoretical prop power draw (3.0 exponent). 

D.

 Fuel consumption based on theoretical propellar HP draw.Your fuel consumption will vary higher or lower depending 

on your vessel and operating conditions.

Output rating 

CONTINUOUS 

MEDIUM 

HIGH OUTPUT

FWHP (kW)  

340 (252)  

425 (315)  

525 (389)

 

Maximum  RPM 

1800 2100 2100

 

Cylinders / Con

fi

 guration / Cycle 

6 / Inline / 4 

6 / Inline / 4 

6 / Inline / 4

Displacement CID (ltr) 

763 (12.5) 

766 (12.5) 

766 (12.5)

Aspiration 

All Models:

 Turbocharged Aftercooled

 

Bore x Stroke  in (mm) 

All Models

: 5 x 6.5 (127 x 165)

 

 

Cooling 

(General)

Coolant circ pump 

fl

 ow - US gal (ltr) 

73 (232) 

85 (277)  

85 (277)

 

Heat rejection to jacket water - BTU-min 

6,690 8,363 10,331

 

Cooling

 (Heat Exchanger) 

HE engine coolant capacity - US gal (ltr) 

14.25 (54) 

14.25 (54) 

14.25 (54)

Rawwater intake/discharge dia. - in (mm) 

3 (75)  

3 (75) 

3 (75)

Rawwater pump 

fl

 ow - gpm (lpm)/rpm 

92 (348) 

99 (374) 

99 (374)

 

Rawwater pump max. suction head - in (m) 

39 (1) 

39 (1) 

39 (1)

Max. raw water temp. at inlet -°F (°C) 

86° (30°) 

86° (30°) 

86° (30°)

Cooling

 (Keel Cooled)

 

Based on 70° F seawater and minimum full boat speed of 8 knots. 
Return water from keelcooler  

70°-130° F. 

70°-130° F. 

70°-130° F.

KC engine coolant capacity - US gal (ltr) 

11.75 (44)  

11.75 (44) 

11.75 (44)

Water hose inside diameter - in (mm) 

3 (75)  

3 (75) 

3 (75)

 

Head diameter - in  

All Models:

 2” NPT or 3” hose barb

 

Turbo tube length - ft (m) 

48 (14.6) 

64 (19.5) 

80 (24.4)

 

1 in. plain round tube length - ft (m) 

112 (34.1) 

140 (42.7) 

174 (53)

 

Skin cooler aluminum - sq ft (m

2

51 (4.7) 

64 (5.9) 

80 (7.4)

 

Skin cooler steel - sq ft (m

2

170 (15.8) 

212 (19.7) 

263 (24.4) 

Electrical

Voltage 

All Models

:  24V standard (12V optional) 

Min. battery capacity - 24 volt 

All Models

: 2 x 225 amp hours - 1150 CCA 

Battery cable size up to 10 ft run 

“00” “00” “00”

Standard panel harness length - ft (m)

 

All Models

: 20 ft (6m) std, 40 & 60 ft optional 

Air and Exhaust

Engine air consumption - cfm (m

3

/min) 

816 (23.1) 

1029 (29.1) 

1264 (35.8) 

Min. engine room vent area - sq in (m

2

240 (0.16) 

301 (0.19) 

370 (0.24) 

Exhaust gas 

fl

 ow at - cfm (m

3

/min) 

1819 (52) 

2243 (63.5) 

2815 (79.7) 

Exhaust gas temperature -°F (°C)

 

738 (392) 

725 (385) 

736 (391) 

Max. exhaust back pressure - in (mm) H

2

30 (762) 

30 (762) 

30 (762) 

Suggested dry exhaust I.D. - in (mm)

 5(125) 

 

6(150) 

6(150) 

Suggested wet exhaust I.D. - in (mm)

 

8(203) 8(203) 8(203) 

Fuel and Oil

Minimum fuel suction line - in (mm)

 

0.5 (12) 

0.5 (12) 

0.5 (12)

Minimum fuel return line - in (mm) 

 

0.375 (10) 

0.375 (10) 

0.375 (10)

Maximum fuel pump head - in (m)

 

39 (1) 

39 (1) 

39 (1)

Crankcase oil capacity - US qts (ltr)

 

44 (42)  

44 (42)  

44 (42) 

Other Data

Engine rotation (facing 

fl

 ywheel)

 

All Models

: Counter-Clockwise 

 

Flywheel housing size 

 

All Models

Std. SAE 1, 14” Std. (SAE 2, 11.5” opt)

Optional front PTO size 

 

All Models

: SAE 4, 10” or  SAE 3, 11.5” 

Max operating down angle - front/rear

 

0°/12° 0°/12° 0°/12°

Approximate Weight*

Dry weight with HE, no gear - lbs (kg) 

3210 (1456)  

3210 (1456)  

3210 (1456) 

Dry weight, KC, no gear - lbs (kg)  

3093 (1403)  

3093 (1403)  

3093 (1403) 

L1276A2 Speci

fi

 cations and Installation Data

L1276A2 Performance  Data

Dealer

4420 14th Ave. NW., Seattle WA 98107  

Tel: (206) 789-3880  • 1-800-762-0165 • Fax: (206) 782-5455  

Information and dimensions subject to change without notice.

 

Northern Lights and Lugger are registered trademarks 

of Northern Lights, Inc.  

© 2005 All rights reserved. Litho USA. L654 3/08

www.northern-lights.com

Dimensions inch 

(mm)

A length 

69.94 (1776)

B width 

46.02 (1169)

C height 

41.31 (1049)

D mounts 

34.55 (878)

E mounts 

26.0 (660)

*Do NOT use for installation. Contact factory for current installation drawings.

High Output Rating

1

 

FWHP / kW / @ rpm

 

525 / 389 / 2100

Medium Duty Rating

1

 

FWHP / kW / @ rpm

 

425 / 315 / 2100

Continuous Duty Rating

 

FWHP / kW / @ rpm

 

340 / 252 / 1800

HIGH OUTPUT

1

A B C D

ft/lbs fwhp pdhp gph

1291 246  55  2.8

1609 368  95  4.6

1775 473 151 7.3

1775 541 224 11.4

1628 558  318  16.1

1435 546  438  22.0

1315 525  507  25.5

CONTINUOUS

A B C D

ft/lbs fwhp pdhp gph

-- -- -- --

1120 256  97.5  4.9

1114 297 154 7.5

1116 340 231 11.4

992 340 328 16.3

-- -- -- --

-- -- -- --

MEDIUM DUTY

1

A B C D

ft/lbs fwhp pdhp gph

1439 274  44.4  2.2

1440 329  76  3.8

1441 384 122 6.1

1517 432 181 9.2

1351 463 259 12.6

1211 461 354 17.3

1062 425 410 23.4

RATING

Curve

RPM

1000

1200

1400

1600

1800

2000

2100

Отзывы: