North Star NSDW500 Скачать руководство пользователя страница 3

3

Parts of the System

Materials and Tools Needed

Typical Undersink Installation

   filter system assembly

   filtered water faucet for sink or countertop mounting

   3/8" tubing to make all needed connections

NOTE:

Gather the required tools before starting installation. Read and follow

the instructions provided with any tools listed here.

   filtered water faucet for sink or countertop mounting

   slotted and Phillips screwdrivers

   pliers and adjustable jaw wrench

   tubing cutter

   electric drill and 1-1/4" drill bit if mounting hole is needed for the faucet

IMPORTANT:

To avoid damaging the sink, consult a qualified plumber or

installer for drilling procedures in porcelain or stainless steel.

Locate the water filter housing on the cold water supply pipe, under the kitchen and/or bathroom sink, to

filter the cold drinking water. Refer to the following drawing.

shutoff valve

filtered water faucet

(not included)

Filter 2

(post filter)

Filter 1

(pre filter)

Blue

WATER

OUT

Yellow

WATER

IN

water supply

fitting

SINK

NOTE:

Be sure to allow a minimum space of 1-1/2" under the system

for removing the filter cartridges, in order to change the cartridges.

Fig. 1

4-1/4”

HOT

COLD

Содержание NSDW500

Страница 1: ...ned Engineered Assembled in the U S A How to install operate and maintain your Undersink Drinking Water Filter System Model NSDW500 If you have any questions or concerns when installing operating or m...

Страница 2: ...on disinfected waters that may contain filterable cysts q All plumbing should be done in accordance with local codes and requirements In Massachusetts plumbing code 248 CMR 3 00 and 10 00 shall be ad...

Страница 3: ...c drill and 1 1 4 drill bit if mounting hole is needed for the faucet IMPORTANT To avoid damaging the sink consult a qualified plumber or installer for drilling procedures in porcelain or stainless st...

Страница 4: ...t s to relieve pressure 2 Disconnect the existing cold water line from the water shutoff valve 3 Make sure that the water supply fitting s gasket is inside the female threaded portion of the fitting 4...

Страница 5: ...e for this 1 Select one of the following places to install the faucet Be sure there s room underneath so you can make the needed connections In an existing sink spray attachment hole Drill a hole in t...

Страница 6: ...ilter system outlet Figure 1 Tubing Connection all push in fitting locations This system includes push in fittings for quick tubing connections If working with the fittings do the fol lowing Connect T...

Страница 7: ...NSDW500 with replacement element pack 7358195 conforms to NSF ANSI 42 and 53 for the specific performance claims as verified and substanti ated by test data The rated capacity for this system is 270...

Страница 8: ...8 Exploded View 8 1 2 3 4 3 6 5 7...

Страница 9: ...ounting Hardware Kit includes 2 ea of Key Nos 6 7 6 Hanger Washer 2 req d 7 Screw 2 req d 201 8404054 Owner s Manual OPTIONAL ITEMS not included 8 WHEFCHR Faucet Chrome WHEFSAT Faucet Brushed Nickel P...

Страница 10: ...rsink Drinking Water Filter System is operated at water pressures not exceeding 100 psi and at water temperatures not exceeding 100 F provided further that the Undersink Drinking Water Filter System i...

Страница 11: ...ed tap water at a flow rate of 0 5 gpm 1 9 L min pH of 7 5 0 5 pres sure of 60 psig and temperature of 68 5 F Installation Requirements Pressure Range 30 100 psig 207 689 kPa Temperature Range 40 100...

Страница 12: ...ide EDB 44 0 024 99 0 05 Haloacetonitriles HAN NA Bromochloroacetonitrile 22 0 55 98 NA Dibromoacetonitrile 24 0 65 98 NA Dichloroacetonitrile 9 6 0 25 98 NA Trichloroacetonitrile 15 0 35 98 NA Contam...