North Star A1573001 Скачать руководство пользователя страница 5

Grounding Instructions 

  5 

 
 

Your product must be grounded. If your product should malfunction or breakdown, grounding provides a path 
of least resistance for electric current to reduce the risk of electrical shock. Your product should be equipped 
with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an 
appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. 
 
     

DANGER

 - Improper connection of the equipment - grounding conductor can result in a risk of 

electrocution. Check with a qualified electrician or service personnel if you are in doubt as to whether the outlet 
is properly grounded. Do not modify the plug on your product - if it will not fit the outlet; have a proper outlet 
installed by a qualified electrician. Do not use any type adapter with this product. 
 

GROUND FAULT CIRCUIT INTERRUPTER PROTECTION

 

Your electric pressure washer should have a ground fault circuit interrupter (GFCI) built into the plug of the 
power supply cord. This device provides additional protection from the risk of electric shock. Should 
replacement of the plug or cord become necessary, use only identical replacement parts that include GFCI 
protection.  If your power supply cord does not included a built in (GFCI) ensure the receptacle is protected by 
a (GFCI).

 

 

Extension Cords

 

 

Use only 3-wire extension cords that have 3 prong grounding-type plugs and 3-pole cord connectors that accept 
the plug from the product. Use only extension cords that are intended for outdoor use. These extension cords are 
identified by a marking “Acceptable for use with outdoor appliances; store indoors while not in use.”  Use only 
extension cords having an electrical rating not less than the rating of the product. Do not abuse extension cord 
and do not yank on any cord to disconnect. Keep cord away from heat and sharp edges. Always disconnect the 
extension cord from the receptacle before disconnecting the product from the extension cord. 
 

     WARNING

 - To reduce the risk of electrocution, keep all connections dry and off the ground. Do not touch 

plug with wet hands.

 

 

SAVE THESE INSTRUCTIONS

Содержание A1573001

Страница 1: ...t company that delivered the unit and file a claim If you have missing components Contact Customer Service at 1 800 270 0810 Read this manual Serious injury or death can result if safety instructions...

Страница 2: ...Hazard Signal Word Definitions 2...

Страница 3: ...ation 6 Operation Instructions 7 8 Water Supply 7 Start Up Shut Down Instructions 7 Applying Chemicals 8 Maintenance and Storage 9 11 Maintenance Mode and Maintenance Schedule 9 Pump Oil Change 10 Win...

Страница 4: ...ken or missing parts Never alter the manufacturer s original design or deactivate any safety device on the machine 11 Risk of exposure to dangerous chemicals Wear protective gloves when handling and c...

Страница 5: ...interrupter GFCI built into the plug of the power supply cord This device provides additional protection from the risk of electric shock Should replacement of the plug or cord become necessary use onl...

Страница 6: ...Pump Component Identification 6 A157306 A1573001 A1573021 A1573011 A1575581...

Страница 7: ...water supply Do not use rigid piping SHUT DOWN INSTRUCTIONS 1 Turn motor OFF 2 Unplug the power cord 3 Turn water supply OFF 4 Squeeze trigger to relieve system pressure 5 Remove garden hose 6 Remove...

Страница 8: ...the chemical injector draw water through the strainer until all the chemical is purged from the system Risk of exposure to dangerous chemicals Serious injury or death can result if chemical manufactur...

Страница 9: ...What to Do Inlet Filter Each Use Visually inspect and clean inlet filter with clear water Pressure Hose Each Use Visually inspect pressure hose and hose couplings Replace hose if any of the following...

Страница 10: ...hrow it in the trash pour it on the ground or down the drain 4 With the pump in a level position fill to the halfway point on the oil sight glass see pump oil capacities below For Comet pumps use Univ...

Страница 11: ...ow the storage instructions listed above 2 Make sure the motor start switch is OFF 3 Attach the garden hose with funnel to the pump inlet see illustration 4 Pour RV antifreeze into the funnel run moto...

Страница 12: ...zle Remove nozzle check for blockage G Worn nozzle Replace nozzle H Leak in pressure hose Replace pressure hose I Wrong nozzle Make sure chemical nozzle is being used J Back pressure from extra long d...

Страница 13: ...575581 PSI bar 2750 190 PSI bar 1500 103 GPM l min 2 5 9 4 GPM l min 2 0 7 5 Max Water Temp 140 F 60 C Max Water Temp 140 F 60 C Horsepower Required 5HP Electric Motor Horsepower Required 2HP Electric...

Страница 14: ...Parts Explosion MA1573001 Rev A 1 14...

Страница 15: ...le 1 A1573011 3021 5581 6 35918 Thermal Protector 1 A1573011 3021 5581 7 777347 Tee Forged 1 A1573021 8 777347 3 8 Easy Start Valve 1 A1573021 9 777340 1 4 Hose Barb 1 A1573021 10 777834 1 4 Hose Clam...

Страница 16: ...Pump Exploded Views 16 A1573001...

Страница 17: ...Pump Exploded Views 17...

Страница 18: ...Pump Exploded Views 18 A1573011...

Страница 19: ...Pump Exploded Views 19 A1573021...

Страница 20: ...Pump Exploded Views 20 A157306...

Страница 21: ...Pump Exploded Views 21...

Страница 22: ...Pump Exploded Views 22 A1575581...

Страница 23: ...23 This page has intentionally been left blank...

Страница 24: ...24 Manufactured by Northern Tool Equipment Co 2800 SouthCross Drive West P O Box 1499 Burnsville MN 55337 0499...

Отзывы: