230V DOWNLIGHT 

36-3854 / 36-3855

INSTRUCTION MANUAL

Page 2

ENGLISH

Page 1

Safety instructions

Carefully read this instruction manual before commencing the installation. 

The distributor is not liable for any damages if the installation does not comply

with these instructions. Keep this instruction manual for future reference.

All light fittings must be installed correctly to avoid danger to life and material.

This light fitting is made for fixed installation and requires installation by a 

qualified electrician.

Repairs must be carried out by a qualified electrician.

To fulfill the IP 44 rating, the downlight must be flush mounted into a waterproof

and homogeneous ceiling where water cannot reach the recessed parts.

Before cleaning the downlight disconnect from mains and allow the downlight

to cool down. Only use a dry cloth and never use detergent or other strong

fluids.

The light fixture is only made for cable installation.

This is a class II luminarie and shall not be connected to earth/ground.

If the protective glass in front of the bulb is broken it must be replaced 

immediately.

Mounting in ceiling

All light fittings generate heat and therefore an area of free air is required around

the downlight. See below drawings for minimum requirements. When the

downlight is mounted into a ceiling 

with insulation

, the insulation must be kept

away from the fitting by a mounting box. The box can be purchased or built

in for example wood. When mounted in ceilings 

without

 insulation make sure

good ventilation around the downlight is ensured.

Installation

Ensure power is disconnected before commencing the installation. Connect

the downlight to 220-240V ac power supply. The fixture is double insulated, class

II, and should not be connected to earth/ground. Connect phase wire “L”,

usually black or brown, and neutral “N” blue to terminals marked with L and N.

Change of bulb

Ensure power is disconnected to the fixture before attempting to change the

bulbs. Let the bulb cool down before replacement otherwise risk of burns may

occur. Turn the front ring anticlockwise to change the bulb.
This downlight is adapted to fit different kinds of bulbs with GU10 socket.

Halogen

:

Max 50 W, 230V with aluminum reflector. Cold beam 

reflector can not be used.

Energy saving (CFL) :

Max 9 W. Note that energy saving bulbs (CFL) are longer

and this limits the tilt angle

LED

:

Max 3 W

Specifications

Type Nr

: OTL-8

Power

:  220-240 V AC, 50 Hz

Class

: II (Shall not be connected to earth/ground)

IP class

: IP44 recessed in a waterproof ceiling

Beam angle

: Tilltable 30º, non-swivel

Bulb

: Max 50 W,  220-240V AC, GU 10

Min. distance

: 0.5m (to nearest object)

Hole size

: Ø 82mm

Outer diameter : Ø 95mm

Recessed space :  H: 150mm, B: 300mm, D: 300mm

Min. wire area

: 2 x 0.75mm

2

ENGLISH

300mm

150mm

Insulation

Installation into ceiling with insulating material

50mm

150mm

90mm

82mm

Installation in ceiling without insulation material