5.

 

IC Statement 

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the 
following two conditions

:

 

(1) this device may not cause interference, and 
(2) this device must accept any interference, including interference that may cause undesired operation 
of the device. 
 
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de 
licence. L'exploitation est autorisée aux deux conditions suivantes :  
(1) l'appareil ne doit pas produire de brouillage, et  
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est 
susceptible d'en compromettre le fonctionnement. 

 

 

This equipment complies with Canada radiation exposure limits set forth for uncontrolled 
environments. This transmitter must not be co-located or operating in conjunction with any other 
antenna or transmitter. 

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Eagle 1

Страница 1: ...7 P O Box 27 2520 La Neuveville Switzerland T 41 32 751 29 64 F 41 32 751 29 35 info northeagles ch EAGLE 1 H2S Gas Detector Watch Operating Instructions Revision 3 Approval by Checked by Originated...

Страница 2: ...1 29 35 info northeagles ch Versions Revision Date Editor Modifications 1 31 07 2018 OV Initial release 2 22 03 2018 OV US certification additions 3 07 08 2018 OV FCC certification additions Reference...

Страница 3: ...Watch 7 6 2 Time Display 7 7 Setting The Time 8 7 1 Setting The Minutes And Hour Time 8 8 Alarm 9 8 1 Alarm Mode 9 8 2 Time In Alarm Mode 9 9 TWA and Exposed Duration 10 9 1 TWA Display 10 9 2 Maximu...

Страница 4: ...EAGLES gas detecting watch Eagle 1 is a single gas detection instrument manufactured by NORTH EAGLES in Switzerland The watch permanently measures the concentration of H2s gas in the ambient air and...

Страница 5: ...ding interference that may cause undesired operation Caution The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user s au...

Страница 6: ...nterference that may cause undesired operation of the device Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e...

Страница 7: ...d the hands a set at 9 0 clock and the disc is set on SENSOR 6 1 Activation Of The Watch The watch is delivered in SLEEP mode and can only be activated via the application Cf User s manual for the app...

Страница 8: ...s in hours SETTING and the disc indicates DETECT Press the EXP pusher to increment hours Press the EXP pusher to decrement hours To change minutes hours quickly press both pushers simultaneously To re...

Страница 9: ...reverts to TIME mode 8 1 Alarm Mode In ALARM mode the disc indicates DETECT The hour hand indicates the actual gas detected on the gas detection display scale The minute hand indicates the maximum ga...

Страница 10: ...er EXP to display the TWA The disc will indicate the TWA The minutes hand will move to the 9 o clock position and the hour hand To re instate the TWA press both pushers simultaneously during 3 seconds...

Страница 11: ...omatically return into HEURE hour mode after 10 seconds 10 2 Re initialisation Of The Deadline For Recalibrating The Sensor From the EOL SENSOR mode press both pushers simultaneously for 3 seconds A b...

Страница 12: ...hen thebattery isdischarged 5 thewatch doesnolonger display thetimeofday and thediscwill display BATT and the hour hand will indicate the lowest point on the scale marked REPLACE on the dial 10 7 Prio...

Страница 13: ...disc is not exactly on DETECT or if the hands are not exactly on 12 0 clock a calibration is necessary Press pusher EXP to move the hour hand by one step clock wise Press the pusher EOL to turn the ho...

Страница 14: ...se is to avoid battery discharge When in this mode the gas detection is disactivated The hands are resting at 9 o clock and the disc is resting on SENSOR The watch will keep the time but will not disp...

Страница 15: ...G EII4644 SEV 17 ATEX 0148 X Electrical safety IECEx SEV 17 00 14X Ex ia IIC T4 Ga C E 1258 Class I Zone 0 AEx ia IIC T4 Ga Cl Div 1 Gp A B C D T4 40 C Tamb 50 13 2 Operational Temperatures 40 C 50 C...

Страница 16: ...underpoint11 3 Usingadifferent battery could significantly affect the intrinsic safety of the watch and its functioning would not be guaranteed any longer Never change the battery in a dangerous or ex...

Отзывы: