Nortel Station Port Adapter DS30 Скачать руководство пользователя страница 5

4

Installation Guide

DS30/Station Port Adapter

SITUATION

INDICATION

LINK

ACTION

Fiber Line LED light is

Power on

Invalid

Check fiber

flashing

connection between
units

Fiber Line LED light is off

No Power

Invalid

Check power source

Fiber Line LED light is on

Power on

Valid

None

TCM Loop LED port light

Active port

Valid

None

is on

connection

TCM Loop LED port light

Inactive port

Invalid

Check corresponding

is off

connection

port connection

TROUBLESHOOTING

Table 3.   Troubleshooting Guide

NOTE:

Timing master uses highest numbered TCM Loop connected
port to synchronize DS-30 link.

The DS30/Station Port Adapter is compatible with ACCESS 2.6
ver. 6.52 and higher within application products running on the
NAM II platform. Systems with previous versions of ACCESS
should obtain an appropriate upgrade.

Figure 4.  Close-up View of LEDs

TCM Loop 1

Fiber Line

1

  

4  7

2  5  8
3  6 

 

FIBER
LINE

Содержание Station Port Adapter DS30

Страница 1: ... DS30 Station Port Adapter Installation Guide ...

Страница 2: ...uipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules The limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruc...

Страница 3: ...6 129 mm x 1 22 36mm WEIGHT Estimated 20 ounces 567 grams includes bezel and PCB but not wall mounted power supply POWER Country Output Input Rating North America 12VAC 600mA 110VAC United Kingdom 12VAC 600mA 240VAC Australia 12VAC 600mA 240VAC RELIABILITY Mean time before failure MTBF target is greater than 20 years using Mil Std 217F method TBD reliability calculations FUNCTIONAL Multiplexes up ...

Страница 4: ...nector of adapter 4 Plug power cord into AC Power Connector 5 Plug the adapter power into anAC wall outlet WARNING Use only UL CSA cUL approved Class 2 Wall Mount Power Supply with a rated output of 12VAC Figure 2 TCM Loop RJ 45 Pinout Connections Female RJ 45 JP1 TCM Loops 1 4 4 3 2 1 1 2 3 4 8 7 6 5 4 3 2 1 Loops 1 4 Pins 1 8 To Norstar KSU To Adapter RJ 45 Connector Female RJ 45 JP1 TCM Loops 5...

Страница 5: ...ction TCM Loop LED port light Inactive port Invalid Check corresponding is off connection port connection TROUBLESHOOTING Table 3 Troubleshooting Guide NOTE Timing master uses highest numbered TCM Loop connected port to synchronize DS 30 link The DS30 Station Port Adapter is compatible with ACCESS 2 6 ver 6 52 and higher within application products running on the NAM II platform Systems with previ...

Страница 6: ... Norstar is a trademark of Northern Telecom P0878745 Issue 01 Printed in the United States ...

Отзывы: