Equipment description
Page 29 of 80
Meridian Data Services
Description
2W—4W
The 2W position provides for local echo while the 4W
position does not provide for echo. The QMT8 labels this
switch as Echo—No Echo.
ECHO—NO ECHO
This is a QMT8 switch assignment: The Echo position
provides for local echo, while the No Echo position does not
provide for echo from the ADM.
MANUAL—AUTO ANS
This establishes how calls to the ADM are answered:
manually or automatically.
OFF—LOOPBACK
This switch is used by maintenance personnel to test ADM
using the loopback setting. The switch is OFF during regular
transmissions (Note 2).
Synchronous ADM Operation (QMT8 and higher)
S3.1 and S3.2
(Not used by synchronous QMT8 or QMT12)
HDX—FDX
Provides for the transmission aspects: HDX when
half-duplex direction of transmission is under dynamic
control of EIA leads CTS, RTS, and CD (this switch provides
local carrier monitoring of local request-to-send to ensure
compatibility with 2-wire modem); FDX when full-duplex
communications is required.
Modem—Network
This is a synchronous QMT8/QMT12 switch assignment:
Modem is used (clocks are not synchronized) for all
connections except for connections to a digital network;
Network is used when the transmit and receive clocks are
jointly synchronized.
Extþclock—Intþclock
This is a synchronous QMT8/QMT12 switch assignment: Ext
clock is used when a device connected to the ADM controls
the transmission clock; Int clock is used when the Meridian 1
controls the transmission clock.
Table 2
ADM user option selectors (Part 2 of 3)
Selector
Description