OAM&P description
6-21
Planning Guide NT6Q92MA Rel 1.0 Iss 1 Standard September 2006
Note:
The OME6130 supports nodal provisioning. When provisioning an
end-to-end circuit, you must ensure that the traffic protection as well as
cross-connections are performed at the end-points as well as any
passthrough nodes that make up the end-to-end circuit.
For detailed procedures for SNCP protection, refer to
Provisioning and
Protection Switching Procedures
, 323-1855-310.
SNCP protection switch criteria
A SNCP protection switch request can occur automatically by the system or
by user initiated actions.
summarizes the hierarchy of protection commands.
For a complete description and procedures, see
Provisioning and Protection
Switching Procedures
, 323-1855-310.
Unprotected connections
Unprotected configurations consists of end-to-end paths that do not have an
alternate path. In the case of the a fault on the unprotected path, traffic is lost.
Note:
Unprotected is the default traffic protection configuration for the
port interfaces in OME6130.
Table 6-8:
SNCP protection - command hierarchy
Switch request
Priority
Lockout of protection
1 (Highest)
Forced switch
2
Auto switch (P-AIS, P-LOP, P-UNEQ)
3
Auto switch (P-SF)
4
Auto switch (P-SD)
5
Manual switch on protection path
6
Manual switch on working path
7
Wait-to-Restore
8 (lowest)