Technical specifications
7-21
Planning Guide NT6Q92MA Rel 1.0 Iss 1 Standard September 2006
For applications with the 28xE1/DS1 circuit pack, right routing E1 or DS1
cables must be used. The cable connectors for the right routing cables must
comply to the specifications provided in
. Refer to
for more details.
Table 7-20
Cable specifications for connecting DS1 ports
Feature
Physical specification
Conductor
24 AWG solid tin plated copper
Insulation
Solid polyolefin or solid Polyethylene
Pairs
Two conductors twisted into pairs with varying lay length
Pair groups
32 twisted pairs are cabled together
Jacket
32 pair groups are jacketed with PVC
Colour Code
Refer to
for colour coding information
Shield
24 AWG tinned copper drain wire over the foil with a 34 AWG tin plated
copper braid, 65% coverage.
Jacket
Gray PVC jacket. Overall dimension 14.0 mm Nom.
Electrical Characteristics
Impedance
100 +/- 15 Ohms Nom.
Capacitance
13.3 pF/ft Nominal
Velocity of propagation
65% Nominal
Near End Cross Talk
(NEXT) pair to pair
53 dB at 20 MHz
Dielectric Strength
Conductor to Conductor
2.5 KV DC
Core to Sheath
2.3 KV DC
Table 7-21
Connector specifications for right routing E1/DS1 cables
Feature
Physical specification
Connector
Connector type
64 POS Male AMP Champ (0.085) or equivalent ‘key telephone’
connector
Latching hardware
4-40 screws - 2 places
Component
Minimum 30uin Au over 50uin Ni plating on contacts