Nortel NN10364-301 Скачать руководство пользователя страница 1

NN10364-301

Multimedia Communication Portfolio

Multimedia Communication Server

2-server Sun Fire V100 Solaris Installation and Commissioning 

Guide

MCS 5100 3.5 

Standard

 6.0

 December 2006

Содержание NN10364-301

Страница 1: ...NN10364 301 Multimedia Communication Portfolio Multimedia Communication Server 2 server Sun Fire V100 Solaris Installation and Commissioning Guide MCS 5100 3 5 Standard 6 0 December 2006...

Страница 2: ......

Страница 3: ...omer provided PC 23 Setting up the baseline hardware 25 Baseline hardware 25 Setting up rack to mount hardware 27 Connecting the Sun Fire V100 server to the layer 2 switch 28 Connecting the Sun Fire V...

Страница 4: ...license key 79 Installing and launching the System Management Console 95 Prerequisites 95 Installing the System Management Console 95 Launching the System Management Console 96 Adding a server 101 Pr...

Страница 5: ...33 Installing and configuring the Oracle Monitor 139 Prerequisites 139 Procedures 139 Installing the iPlanet Monitor 147 Prerequisites 147 Procedures 147 Verification procedures 161 Verifying Server1...

Страница 6: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 6 Copyright 2006 Nortel Networks...

Страница 7: ...o the latest documentation and software for MCS 5100 click one of the following links Link to Takes you directly to the Latest Software Nortel page for MCS 5100 software located at www130 nortelnetwor...

Страница 8: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 8 Copyright 2006 Nortel Networks...

Страница 9: ...oad software documentation and product bulletins search the Technical Support Web site and the Nortel Knowledge Base for answers to technical issues sign up for automatic notification of new software...

Страница 10: ...n use an Express Routing Code ERC to quickly route your call to a specialist in your Nortel product or service To locate the ERC for your product or service go to www nortel com erc Getting help throu...

Страница 11: ...is document describes the installation of the 2 server Sun Fire V100 Solaris system The 2 server Sun Fire V100 Solaris system must be connected to a 100 MB full duplex Ethernet switch The IP configura...

Страница 12: ...our own configuration to assist in executing this installation Configure the pc you are using for management services with an IP address that is in the same subnet of the IP address range used for the...

Страница 13: ...Solaris system has a mirrored disk In the event of a disk failure the failed disk should be replaced as soon as possible The 2 server V100 Solaris system has the following limitations The system suppo...

Страница 14: ...00 Provisioning Client User Guide NN42020 105 MCS 5100 H 323 Gatekeeper Basics NN10280 111 Media Application Server Network Engineering and Deployment Guide NN10377 191 MCS 5100 Ad Hoc Audio Conferenc...

Страница 15: ...Sun Fire V100 Solaris Installation and Commissioning Guide 15 Copyright 2006 Nortel Networks MCS 5100 Fault Management Alarm and Log reference NN10385 900 MCS 5100 Performance Management OM reference...

Страница 16: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 16 Copyright 2006 Nortel Networks...

Страница 17: ...Networks strongly recommends the use of high speed data network connectivity for optimum remote service capability Without broadband connectivity remote service options are limited Nortel Networks re...

Страница 18: ...g and no such activities are planned for the duration of the installation procedures and follow up soak period You have a detailed knowledge of your network s configuration You have proficiency using...

Страница 19: ...or buttons that you must press to perform an action for example Apply Courier type is used to signify what appears on screen for example Enter your password Italic type is used for emphasis for speci...

Страница 20: ...he same CDs on both servers at the same time to reduce installation time As shown in Table 2 Mapping of Kit NTVW01BD disks to servers with times Disks 1 5 have four copies each Disk 6 only needs to go...

Страница 21: ...pproximatetime to install Server 1 Server 2 Management PC CD1 Disk Partitioning Solaris OS Kernel 45 minutes X X CD2 Solaris OS Packages 15 minutes X X CD3 Solaris Packages and Patches 90 minutes X X...

Страница 22: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 22 Copyright 2006 Nortel Networks...

Страница 23: ...inimum 64MB of RAM This requirement is in addition to the memory requirements of the operating system and other concurrent applications recommended 64MB of RAM This requirement is in addition to the m...

Страница 24: ...applicable operating systems minimum Microsoft Windows 98 SE ME 2000 XP or Microsoft Windows NT 4 x with Service Pack 5 SP5 recommended Microsoft Windows 98 SE ME 2000 XP or Microsoft Windows NT 4 x w...

Страница 25: ...he following figure for an overview of the hardware connectivity Figure 3 Hardware connections overview ATTENTION You need an uninterrupted power source UPS If a power outage occurs bring the server f...

Страница 26: ...12 KB On Chip L2 Cache 1 GB Memory 2 40 GB 7200 RPM IDE Disk second disk for mirroring CD ROM 2 10 100 Mbit Ethernet and USB Ports System configuration card Solaris 8 and LOMlite2 pre installed two 2...

Страница 27: ...Database Management Accounting server Application server optional equipment Mount conference server Refer to the Media Application Server documentation for more information optional equipment Mount ga...

Страница 28: ...ack Connecting the Sun Fire V100 server to the layer 2 switch Procedure 2 Connecting the V100 server to the layer 2 switch At the back of the Sun Fire V100 server 1 Connect the Sun Fire V100 server Ne...

Страница 29: ...er through either cascade modules or Ethernet links 2 Plug in the power cords at the back of the V100 server Connecting the Sun Fire V100 server to the MRV LX terminal server The MCS 5100 platform use...

Страница 30: ...The cables with part numbers A0500465 or NTVW01IM are serial cables Note 2 The P1 end goes to the V100 server and the P2 end goes to the MRV LX terminal server ATTENTION If the network is down or the...

Страница 31: ...tion and Commissioning Guide 31 Copyright 2006 Nortel Networks Figure 8 P1 and P2 custom cable connections to terminal server See note Note This cable is only connected to configure the terminal serve...

Страница 32: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 32 Copyright 2006 Nortel Networks...

Страница 33: ...r is not needed and the cable can be removed 2 Connect the MRV terminal server 10 Base T port to the layer 2 switch Refer to the Getting Started with the LX 4000 Series document in the CD that comes w...

Страница 34: ...pyright 2006 Nortel Networks Figure 9 MRV Configuration Console window 2 Make sure you have the Java Plug in installed 3 When your browser connects to the terminal server the Java Security Warning win...

Страница 35: ...nsole also require Java Runtime Environment 1 4 or later Choosing Not Encrypted Console means the GUI will run faster but without security Note The Java cache in JRE 1 4 is set to ON by default There...

Страница 36: ...tel Networks Figure 12 Login window 6 Enter your Username and Password and click Login Note By default authentication is done against the local user database To start use the known username InReach an...

Страница 37: ...Figure 13 User login window 8 To log in as a superuser click the Admin button on the tool bar and log in with the default Superuser password system You can now configure the unit at the GUI 9 Click o...

Страница 38: ...rks Figure 14 Example selecting Ports Async a When you click on a port the following dialog box appears for you to enter your information Note In the TCP window see Figure 15 ensure that both the Teln...

Страница 39: ...ortel Networks Figure 15 Port 19 dialog box For details on using the IP Configuration Menu refer to Using the IP Configuration Menu in the LX Series Configuration Guide For information on how to boot...

Страница 40: ...ed user knew this username password combination that user could log on to your unit For this reason you should change the user s password to something other than access The default Superuser password...

Страница 41: ...password at the Re Enter your NEW password prompt The password will be displayed as asterisks Procedure 8 Accessing the MRV LX terminal server At the management pc 1 Select Start Programs Accessories...

Страница 42: ...command show ports 1 19 telnet chara Enter 13 Save your changes 14 Log out Note Using the command define saves the configuration 15 To kill a session on a port type logout port 12 Enter Procedure 9 C...

Страница 43: ...ports 11 14 The port number identifies the location of the target host This value is based on the following formula 2000 Port number physically connected on the MRV LX terminal server x 100 For examp...

Страница 44: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 44 Copyright 2006 Nortel Networks...

Страница 45: ...s will more than likely boot up to a Solaris System Identification screen Do not answer those questions Send a break to get to the ok prompt so you can then boot from the CD ROM Procedure 11 Power on...

Страница 46: ...CS 5100 3 5 Standard 6 0 December 2006 46 Copyright 2006 Nortel Networks 4 The ok prompt appears ATTENTION If you do not use PuTTY use the appropriate key sequence to send a break to the server to get...

Страница 47: ...d new machine connect through the terminal server to the A LOM port until after you have installed CD5 Then log out Log back in through the terminal server to B Serial port for the rest of the install...

Страница 48: ...or English 0 Enter What type of terminal are you using 5 Select three 3 for DEC VT100 3 Enter Note The following message is displayed The system is coming up Please wait Solaris Installation Program P...

Страница 49: ...le micromgmt Note 1 Host name cannot start with a number Host names must be at least two characters and can contain alphanumeric characters and minus signs Note 2 Host names must be unique within your...

Страница 50: ...you need to change anything Configure Security Policy 12 Confirm the Kerberos information by accepting the default No Press Esc 2 to continue Confirm information 13 Ensure all fields are filled corre...

Страница 51: ...eys to navigate to the required time zone and press the spacebar to mark your choice Press Esc 2 to continue Please wait for the next prompt 18 At the Date and time prompt set up the date and time Pre...

Страница 52: ...The system will reboot upon completion of the install script Wait until you receive the login prompt 23 You will be prompted to type in the root password twice The password will not appear on the scr...

Страница 53: ...ge Ready to Install Install Now Start Over Exit Installation Type 1 for Install Now and press Enter 4 Press Enter several more times to complete the License Agreement Enter Y to accept the license Not...

Страница 54: ...installation will continue Please wait The system will prompt you for the next step 2 Log in as root Enter 3 Enter your customer specific password Enter Note 1 CD 3 will eject from the CD ROM when in...

Страница 55: ...ment and Accounting service will be the source You will need to provide the Machine Logical IP Address of each server If running simplex mode provide the same address twice 2 Press Enter to continue 3...

Страница 56: ...you will be prompted as follows How many external clock sources would you like to reference 1 Enter 1 You will then see the following message External Clock Source IP Address 1 Enter your clock sourc...

Страница 57: ...20 120 13 20 12 Enter the secondary machine physical IP address for the dmfe1 interface Physical IP address of the dmfe1 interface Enter Example 120 120 13 21 13 Enter the machine logical IP addresses...

Страница 58: ...PMP configuration summary Is this IPMP group configuration acceptable Y N Select Y and press Enter 15 The default route IP address should appear If correct press Enter Otherwise type it in then press...

Страница 59: ...cal IP of the AcctMgr in dot notation format Example 120 120 13 22 You have entered the following IP addresses Machine Logical IP Address of the other MgmtSvr 120 120 13 22 Service Logical IP Address...

Страница 60: ...e NTP Source 2 Enter the MACHINE Logical IP Address of the Accounting Server Enter the IP address for example 120 120 13 22 5 You will see the following message You have chosen to configure NTP as fol...

Страница 61: ...Select the three nodes from the following list in order of preference For IPMP GROUPS Machine Logical IP address of the database server Machine Logical IP address of the Management server Machine Log...

Страница 62: ...orrect press Enter Otherwise type it in then press Enter Note If your configuration does not include a router then enter the machine logical IP address of your server 15 Do you intend to deploy the We...

Страница 63: ...MgmtSvr AcctMgr only on page 67 for instructions Application IPCM servers AppSvr IPCM will reboot 2 After the AppSvr IPCM reboot log into these servers using the B Serial port and change the passwords...

Страница 64: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 64 Copyright 2006 Nortel Networks...

Страница 65: ...8 Enabling or disabling the CD ROM auto mount At the management pc 1 The system disables volmgt by default after CD5 is installed To toggle it back on to install additional CDs follow this step Log in...

Страница 66: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 66 Copyright 2006 Nortel Networks...

Страница 67: ...t pc 1 Place CD6 in the CD ROM drive on the server and press Enter at the prompt Note CD6 will eject from the CD ROM when installed 2 After the reboot log in using the B Serial port and change the pas...

Страница 68: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 68 Copyright 2006 Nortel Networks...

Страница 69: ...2 0 4 Procedure 20 Installing Oracle 9 2 0 4 on the database server DBSvr At the management pc 1 Use PuTTY to connect to the database server using Serial port B which connects to the LX terminal serv...

Страница 70: ...receive the following prompts for each CD entered Copying files from CDROM to IMS ora_cds Disk 1 6 Performing check sum on IMS ora_cds Disk 1 6 10 ATTENTION Make sure you put a space before the ending...

Страница 71: ...e default N Enter 15 You will then see a confirmation screen If the information on the screen is correct type Y Otherwise type N and make the changes Note At this point the program runs a check sum an...

Страница 72: ...Disk 1 Disk2 Disk3 Disk4 Disk5 Disk6 from IMS ora_cds Oracle_Install Complete 18 At the completion of the script you will see the message Oracle_Install complete Press Ctrl C to exit 19 To check for...

Страница 73: ...s and configurations Commands are executed on each server using PuTTY SSH into the machine logical IP address ex 120 120 13 25 The procedure to install the database load for the first time is command...

Страница 74: ...Machine Logical IP address Management Server Enter the machine logical IP address of the MgmtSvr Example 120 120 13 22 8 Enter the Service Logical IP address of the SysMgr Example 120 120 13 22 Note...

Страница 75: ...address of the management server At the UNIX prompt the operator the uses the script mgmtdeploy pl to deploy and start the Sysmgr This process is described in the following section Deploying and start...

Страница 76: ...xxx Please enter the number 1 of the load to deploy 1 4 Is the database replicated N Enter 5 Enter Machine Logical IP Address Primary DB machine logical IP address of the database server Example 120 1...

Страница 77: ...ent information Notice that the script waits 30 seconds between process executions The script is starting three processes that must be running in order to continue MCS load deployment The three proces...

Страница 78: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 78 Copyright 2006 Nortel Networks...

Страница 79: ...ieval System webpage The site will normally consist of one or two Management and Accounting servers this set is called the CORE and one or more Media Application Servers MAS Each server has two 2 MAC...

Страница 80: ...ion select a login server that matches your region for example European Login or North American Login 5 In step 2 Product Family select the product you wish to generate keycodes for in this case selec...

Страница 81: ...n Fire V100 Solaris Installation and Commissioning Guide 81 Copyright 2006 Nortel Networks Figure 19 Keycode Retrieval System Creating your site 7 Select Create to register a new system The following...

Страница 82: ...el Networks Figure 20 Keycode Retrieval System Entering your site information 8 Fill in the requested information and press the Continue button Ensure you choose the correct software version from the...

Страница 83: ...Commissioning Guide 83 Copyright 2006 Nortel Networks Figure 21 Keycode Retrieval System Current Summary 9 Select the server you want to enter MAC addresses for first then click on Create 10 Enter the...

Страница 84: ...If you have a second Core that is going to be installed as a redundant server enter all four MAC addresses at this time 12 When finished you will need to select Create again to enter the Media Applic...

Страница 85: ...dia Application Server for your system you must select Create a second time as only two MAC addresses can be associated with any one Media Application Server Figure 23 Keycode Retrieval System Adding...

Страница 86: ...ndard 6 0 December 2006 86 Copyright 2006 Nortel Networks Figure 24 Keycode Retrieval System Current Summary 15 To generate keycodes for this site click on Gen KC with Auth Code from the side bar as s...

Страница 87: ...ieval System Gen KC with Auth Code 16 To generate your keycodes enter one of the MAC addresses of the server you want your Auth code applied to In this case the example shows one of the CORE MAC addre...

Страница 88: ...01 MCS 5100 3 5 Standard 6 0 December 2006 88 Copyright 2006 Nortel Networks Figure 26 Keycode Retrieval System Finding the keycode 18 Select the proper Software Version for your system Then click on...

Страница 89: ...ssioning Guide 89 Copyright 2006 Nortel Networks Figure 27 Keycode Retrieval System Adding a MAC address 19 Enter the authcode number for the feature you wish to enable into the Auth Code box Use the...

Страница 90: ...server type CORE or MAS If validated successfully you will be allowed to enter more authcodes until you ve entered all for your server When this process is complete click on Continue 22 The following...

Страница 91: ...res 23 The KRS will indicate it is generating your keycodes and saving the results in its database After generating the keycodes and saving results in the KRS database the system shows the Retrieve Ke...

Страница 92: ...reens show the features of your keycode and the option to download the keycode to your local PC To download the keycode click on Download Keycode From there you will see the screens to download the fi...

Страница 93: ...Fire V100 Solaris Installation and Commissioning Guide 93 Copyright 2006 Nortel Networks Figure 31 Keycode Retrieval System Retrieving your keycode part 2 24 Download the new license key file to the M...

Страница 94: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 94 Copyright 2006 Nortel Networks...

Страница 95: ...e 25 Installing the System Management Console At the management pc 1 Put the MCS Base Platform System Software CD MCS Management Console PC software into the PC s CD ROM 2 Navigate to the CD ROM drive...

Страница 96: ...lize the whole network view it will take up to a minute for the system manager screen to appear The default base directory where the System Management Console is installed on the management pc is C Pr...

Страница 97: ...cense Key Update menu option from the System tree as shown in Figure 32 Management Console Update License Key The System item on the file tree must be highlighted Figure 32 Management Console Update L...

Страница 98: ...e key file by highlighting the file and pressing Apply Once the file is selected the license key appears in the text area If a wrong file is selected the Open File button can be used to select a diffe...

Страница 99: ...Nortel Networks The console screen has the basic look and feel of a Windows Explorer window with a tree structure on the left and a general information area on the right Each folder on the management...

Страница 100: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 100 Copyright 2006 Nortel Networks...

Страница 101: ...eturn to this chapter Procedure 27 Adding a server At the System Management Console 1 Select Sites MgmtSite Servers 2 Right click on the Servers folder 3 Select Add General 4 Use the following system...

Страница 102: ...address of the server 120 120 13 25 Snmp Port Request Leave the default value as is default Polling interval 240 default Terminal Server Type Drop down menu with the following choices MicroAnnexTermi...

Страница 103: ...gmtSite Servers Add General MgmtSvr See Adding a server on page 101 for information on how to add a server before adding the AcctMgr 2 Click on the plus sign next to the server to which you are adding...

Страница 104: ...ue Notes Example CAM IP Address Name of Server accounting server 192 168 14 11 120 120 13 22 Primary CAM Port 17667 default Recovery CAM Port 17668 default File Rotation Size 100000 Configurable based...

Страница 105: ...Address 0 0 0 0 default TCP IP Primary Host Port 9000 default TCP IP Recovery Host Port 9001 default FTP Push Enabled unchecked default Primary FTP Directory blank default Recovery FTP Directory blan...

Страница 106: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 106 Copyright 2006 Nortel Networks...

Страница 107: ...ervers Add General AppSvr See Adding a server on page 101 for information on how to add a server before adding the SIP Application Module 2 Click on the plus sign next to the server to which you are a...

Страница 108: ...otes Example Authorized SIP Nodes IP addresses of other trusted application servers conference servers and gateways this application module interacts with A trusted relationship implies that this endp...

Страница 109: ...Presence authenticated message Instant Message authenticated Table 2 Authentication tab Sheet 2 of 2 Parameter Recommended value Notes Example Table 3 Local Accounting Manager tab Sheet 1 of 2 Parame...

Страница 110: ...nto the Database Base tab parameters Disk Monitor Critical Threshold 75 default Enable Billing For Instant Message unchecked default Table 3 Local Accounting Manager tab Sheet 2 of 2 Parameter Recomme...

Страница 111: ...mended value Notes Example Primary Host machine logical IP of database server 192 168 14 111 120 120 13 22 Connections 8 default Secondary Host Not applicable Table 7 SIP TCF Base tab Parameter Recomm...

Страница 112: ...s 900 default Update interval for user banned users 900 default IMAuthNonce table size 5 default IMAuthNonce generation interval 60 default Number of call logs 5000 default IM CallLog DB write interva...

Страница 113: ...ers The shaded rows indicate values that must be addressed by the installer Table 11 Server Subscription tab Parameter Recommended value Notes Example provServerURL 120 120 13 25 5095 8 0 http Server...

Страница 114: ...have the ability to park a call For more information see the MCS SIP Application Module Basics NN10259 111 document default Table 14 Server Properties tab Sheet 2 of 2 Parameter Recommended value Not...

Страница 115: ...inued Parameter Recommended value Notes Example Table 16 Transport Management tab Sheet 1 of 3 Parameter Recommended value Notes Example Service Name BBUA default Server ID specific to machine App1 Se...

Страница 116: ...Service Parameter Transport Enabled checked Check the first two Transport Enabled boxes for UDP and TCP that display Uncheck all subsequent instances of Transport Enabled default Protocol SIP default...

Страница 117: ...see the dialog box indicating successful installation The component will appear in the file tree Protocol SIP default Transport TCP default Address Public_Service_Address default Port 5060 default Par...

Страница 118: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 118 Copyright 2006 Nortel Networks...

Страница 119: ...Site Servers Add General AppSvr See Adding a server on page 101 for information on how to add a server before adding the AppSvr 2 Click on the plus sign next to the server to which you are adding the...

Страница 120: ...t Manager tab Sheet 1 of 2 Parameter Recommended Value Notes Example VM Client Contact voicemail default Cluster Name customer specified IPCM cluster name ipcmCluster IP Address machine logical IP of...

Страница 121: ...1 default Use UFTP checked Box is checked default UFTP Server Port 50020 default Keep Alive Timer 40 default KA Phone Timer 90 default Switch Server Delay 5000 default Min ReReg Delay 60000 default Ma...

Страница 122: ...mended value Notes Example LocalHost machine logical IP address of the IPCM server 192 168 14 41 120 120 13 25 Port 5000 default Table 20 SIP TCF Base tab Parameter Recommended value Notes Example Tra...

Страница 123: ...The component will deploy Wait until you see the dialog box indicating successful installation The component will appear in the file tree Table 22 In Memory Database tab Parameter Recommended value N...

Страница 124: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 124 Copyright 2006 Nortel Networks...

Страница 125: ...CM for firmware Add the UFTP to the System Management Console Procedure 34 Adding the UFTP software At the System Management Console 1 Select Sites MgmtSite AppSvr 2 Click on the plus sign next to the...

Страница 126: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 126 Copyright 2006 Nortel Networks...

Страница 127: ...server to which you are adding the component 3 Right click on the Components folder 4 Select Add Component 5 A list of component loads appears in the Load List window Select the latest load for the Pr...

Страница 128: ...24 SIP TCF Base tab Parameter Recommended value Notes Example Transport Config UDP machine logical IP of IPCM Server 5070 optional TCP machine logical IP of IPCM Server 5070 optional Replace each inst...

Страница 129: ...25 User Agent Server tab Continued Parameter Recommended value Notes Example Table 26 Web Client Manager tab Sheet 1 of 2 Parameter Recommended value Notes Example WCM Socket Server Active checked che...

Страница 130: ...ently provides 5 different JRE installers use string 1 4 2_01 1 4 2_02 1 4 2_03 1 4 2_04 or 1 4 2_05 for the corresponding installer for JRE version 1 4 2_01 1 4 2_02 1 4 2_03 1 4 2_04 or 1 4 2_05 You...

Страница 131: ...tatus of the deployment The component will deploy Wait until you see the dialog box indicating successful installation The component will appear in the file tree Table 29 Provisioning Client tab Param...

Страница 132: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 132 Copyright 2006 Nortel Networks...

Страница 133: ...t the System Management Console 1 Select Sites MgmtSite Servers AppSvr 2 Click on the plus sign next to the server to which you are adding the component 3 Right click on the Components folder 4 Select...

Страница 134: ...ws indicate values that must be addressed by the installer 2 Use the values from the table that follows to complete the SIP TCF Base tab parameters ATTENTION Do not click Apply until you have finished...

Страница 135: ...sipLscConduit TCP machine logical IP of the WCM Server 5085 optiona l name sipLscConduit Replace each instance of 0 0 0 0 in the UDP and TCF strings with the machine logical IP address of the Web Clie...

Страница 136: ...ller that the Web Client applet downloads For the latest version of the installer from Sun leave this field empty For the installer provided by the MCS The MCS currently provides 5 different JRE insta...

Страница 137: ...e installer 6 Click Apply 7 The component will deploy Wait until you see the dialog box indicating successful installation The component will appear in the file tree Table 35 Database Base tab Paramet...

Страница 138: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 138 Copyright 2006 Nortel Networks...

Страница 139: ...agement Console At the System Management Console 1 Select Sites MgmtSite Servers MgmtSvr 2 Click on the plus sign next to the server to which you are adding the component 3 Right click on the Componen...

Страница 140: ...click Apply until you have finished configuring the component Table 36 Oracle Server tab Parameter Recommended value Notes Example SNMP request port 9161 default SNMP agent IP address either the word...

Страница 141: ...running on 192 168 14 21 120 120 13 22 Oracle Server name imsdb1 default Oracle Database name imsdb1 default Active checked default Component name TableSpace default Polling interval min 1 default Act...

Страница 142: ...ault Gauged Component Monitoring Threshold monitors Positive going threshold hysteresis 2 5 default Gauged Component Monitoring Threshold monitors Capacity or max value 99 default Gauged Component Mon...

Страница 143: ...Component Monitoring Threshold monitors Alarm Severity on Lower Limit underrun MAJOR default Gauged Component Monitoring Threshold monitors Usage state affected unchecked default Monitor functions Co...

Страница 144: ...default Monitor functions Active checked default Monitor functions Component name CacheHitRatio default Monitor functions Polling interval min 1 default Monitor functions Active checked default Trap...

Страница 145: ...ation The component will appear in the file tree Table 39 Oracle Listeners tab Parameter Recommended value Notes Example SNMP request port 9161 default SNMP agent IP address either the word localhost...

Страница 146: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 146 Copyright 2006 Nortel Networks...

Страница 147: ...te Servers AppSvr 2 Click on the plus sign next to the server to which you are adding the component 3 Right click on the Components folder 4 Select Add Component 5 A list of component loads appears in...

Страница 148: ...heet 1 of 12 Parameter Recommended value Notes Example SNMP request port 8161 default SNMP agent IP address machine logical IP of Provisioning Module 192 168 14 41 120 120 13 25 Active checked default...

Страница 149: ...g Threshold monitors Positive going threshold value 1 70 default Component Monitoring Threshold monitors Positive going threshold hysteresis 1 5 default Component Monitoring Threshold monitors Positiv...

Страница 150: ...monitors Alarm Severity on Maximum Rate MAJOR default Component Monitoring Threshold monitors Alarm Severity on Upper Limit OverRun MAJOR default Component Monitoring Threshold monitors Alarm Severit...

Страница 151: ...toring Threshold monitors Positive going threshold hysteresis 1 5 default Component Monitoring Threshold monitors Positive going threshold value 2 85 default Component Monitoring Threshold monitors Po...

Страница 152: ...Severity on Upper Limit OverRun MAJOR default Component Monitoring Threshold monitors Alarm Severity on Lower Limit OverRun MAJOR default Component Monitoring Threshold monitors Usage state affected u...

Страница 153: ...99 default Component Monitoring Capacity or max hysteresis 0 default Alarm Severity on Negative going threshold NONE default Alarm Severity on Positive going threshold 1 WARNING default Alarm Severity...

Страница 154: ...100 default Component Monitoring Threshold monitors Lower Limit 0 default Component Monitoring Threshold monitors Negative going threshold value 10 default Component Monitoring Threshold monitors Nega...

Страница 155: ...ity on Negative going threshold NONE default Component Monitoring Threshold monitors Alarm Severity on Positive going threshold 1 WARNING default Component Monitoring Threshold monitors Alarm Severity...

Страница 156: ...omponent Monitoring Active for polling checked default Component Monitoring Threshold monitors Gauge name percentThreadPoolUs age default Component Monitoring Threshold monitors Upper limit 100 defaul...

Страница 157: ...reshold monitors Capacity or max value 99 default Component Monitoring Threshold monitors Capacity or max hysteresis 0 default Component Monitoring Threshold monitors Alarm Severity on Negative going...

Страница 158: ...Component Monitoring Component name Web Server Stats default Component Monitoring Polling interval in minutes 1 default Component Monitoring Active for polling checked default Component Monitoring Cla...

Страница 159: ...Apply Wait for the component to appear in server list The iPlanet Monitor is installed on the same server as the Provisioning Module Trap handlers Trap handler name iPlanet Operation Trap default Trap...

Страница 160: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 160 Copyright 2006 Nortel Networks...

Страница 161: ...y IP addressing mcsmicromgmt export home nortel ifconfig a lo0 flags 1000849 UP LOOPBACK RUNNING MULTICAST IPv4 mtu 8232 index 1 inet 127 0 0 1 netmask ff000000 dmfe0 flags 9040843 UP BROADCAST RUNNIN...

Страница 162: ...attempt to attach to the first interface dmfe0 If dmfe0 were unavailable or out of service the machine logical would then attach itself to dmfe1 creating dmfe1 1 The parameters which follow show the...

Страница 163: ...mcsmicroapp export home nortel ifconfig a lo0 flags 1000849 UP LOOPBACK RUNNING MULTICAST IPv4 mtu 8232 index 1 inet 127 0 0 1 netmask ff000000 dmfe0 flags 9040843 UP BROADCAST RUNNING MULTICAST DEP...

Страница 164: ...hine logical would then attach itself to dmfe1 creating dmfe1 1 The parameters that follow show the IP address subnet mask and whether the interface is UP This example output shows that dmfe0 1 is ass...

Страница 165: ...l IP address Example Open a PuTTY SSH session to 120 120 13 22 Procedure 45 Verifying the database load imssipdb deployment At the management pc 1 Log into the database server as nortel new nortel use...

Страница 166: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 166 Copyright 2006 Nortel Networks...

Страница 167: ...zip should be checked 2 Identify the Provisioning Module server s on which to deploy the load 3 Customization of the JNLP file pcclient jnlp is possible by modifying certain attributes For example if...

Страница 168: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 168 Copyright 2006 Nortel Networks...

Страница 169: ...em identification process and then invokes the MCP commissioning script at root login This is the same configuration procedure executed during CD installation and commissioning and is common for all M...

Страница 170: ...arning message This program will unconfigure your system It will cause it to revert to a blank system It will not have a name or know about other systems or networks This program will also halt the sy...

Страница 171: ...P Address Subnet Netmask iPV6 Confirm Security Policy Confirm Note This procedure skips some of the steps for initial installation of CD1 Regions Time Zone Date Time Confirm Password You will then see...

Страница 172: ...se is replicated To make the replication work you must execute the following steps 1 Log in as oracle to the replicated other DB machine 2 issue the command configure_replication 3 restart the databas...

Страница 173: ...ver Sun Fire V100 Solaris Installation and Commissioning Guide 173 Copyright 2006 Nortel Networks b Then log in to the Accounting server and type in the following command usr local bin Interface pl ad...

Страница 174: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 174 Copyright 2006 Nortel Networks...

Страница 175: ......

Страница 176: ...are believed to be accurate and reliable but are presented without express or implied warranty Users must take full responsibility for their applications of any products specified in this document Th...

Отзывы: