MCRM-S card replacement procedures
335
Meridian SL-100 SE Commercial Systems Card Replacement Procedures MSL15
NTMX87
in an MCRM-S EXT or RCC2 shelf
(continued)
23
Use the following information to determine where to proceed.
24
Post the inactive RCC2 in which the NTMX87 card is located by
typing the following string:
> post rcc2 rcc2_no
and pressing the Enter key.
where
rcc2_unit_no
is the number of the RCC2 unit associated with the faulty
card
25
Return the inactive RCC2 unit to service by typing the following
string:
> RTS UNIT rcc2_unit_no
and pressing the Enter key.
where
rcc2_unit_no
is the number of the RCC2 unit posted in Step 24.
26
Use the following information to determine where to proceed.
27
Test the RCC2 by typing the following string:
> TST UNIT rcc2_unit_no
and pressing the Enter key.
where
If RTS
Do
for C-side links passed
Step 24
for C-side links failed
Step 32
for P-side links passed
Step 33
for P-side links failed
Step 32
If RTS
Do
passed
Step 27
failed
Step 32
Содержание Meridian SL-100 SE
Страница 2: ......
Страница 4: ......
Страница 6: ...vi Publication history 555 4031 547 Standard 12 02 July 2002...
Страница 10: ...x Contents 555 4031 547 Standard 12 02 July 2002...
Страница 46: ...46 FSP card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 56: ...56 FSP card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 72: ...72 FSP card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 80: ...80 IPE card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 96: ...96 IPE card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 108: ...108 IPE card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 120: ...120 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 138: ...138 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 149: ...149 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 150: ...150 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 160: ...160 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 187: ...187 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 188: ...188 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 198: ...198 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 208: ...208 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 218: ...218 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 228: ...228 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 252: ...252 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 294: ...294 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 320: ...320 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 322: ...322 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 337: ......