Host error messages A-11
Meridian IVR VT100 Gateway Development Guide Product release 2.0/I
Action to take:
Contact your Nortel service representative.
ERR: Create_idle_timer: Idle timer memory allocation failed
Meaning:
TRS was unable to allocate memory for the idle timer
structure.
Action to take:
Contact your Nortel service representative.
ERR: Configuration file trs.conf not found
Meaning:
Configuration file trs.conf was either not found or not
readable.
Action to take:
Create or change the permissions of trs.conf under 3270
directory.
ERR: No Application field in trs.conf
Meaning:
Application name is not defined in trs.conf.
Action to take:
Revise trs.conf so that it contains the application name
before the ‘:’
ERR: An invalid entry in the trs.conf
Meaning:
An illegal symbol occurred in the trs.conf file.
Action to take:
Check syntax of the trs.conf file.
ERR: Init action missing,put - if not available
Meaning:
Initial action template is missing from the trs.conf file.
Action to take:
Add the initial action template in the trs.conf file or put ‘-’
if not available.
ERR: Ping action missing,put - if not available
Meaning:
Heartbeat action template was missing from the trs.conf
file.
Action to take:
Add a heartbeat action template in the trs.conf file or put ‘-’
in this field if not available.