Page 44 of 64
Attendant console operation
0CH
UIP
A key in column D1 is
stuck.
Same as for
08H
.
0DH
UIP
A key in column D2 is
stuck.
Same as for
08H
.
0EH
UIP
A key in column E is stuck.
Same as for
08H
.
0FH
UIP
A key in column F is stuck.
Same as for
08H
.
A0H
ASIP
The RS-232 has failed the
loopback test.
Check to see if the loopback connector
is inserted. If not, insert it and perform
the loopback test again.
If the failure code still appears, turn the
console off and on while the connector
is inserted.
Perform the loopback test again. If the
failure code still appears, the console
is faulty and should be returned.
90H
ASIP
ASM A44#3, U1, is faulty.
Same as for
40H
.
88H
ASIP
Secondary A44#2, U2, is
faulty.
Same as for
40H
.
84H
ASIP
Primary A44#1, U1, is
faulty.
Same as for
40H
.
82H
ASIP
The UART, U5, is faulty.
Same as for
40H
.
81H
ASIP
The RAM, U8, is faulty.
Same as for
40H
.
Table 4
M2250 failure codes (Part 2 of 2)
Failure
code
Printed
circuit
pack (PCP)
Reason
What to do
Содержание Meridian 1 Series
Страница 2: ......
Страница 8: ...Page 8 of 64 Contents 553 2201 117 Standard 10 00 January 2002 ...
Страница 10: ...Page 10 of 64 About this document 553 2201 117 Standard 10 00 January 2002 ...
Страница 16: ...Page 16 of 64 Introduction 553 2201 117 Standard 10 00 January 2002 ...
Страница 60: ...Page 60 of 64 Attendant console operation 553 2201 117 Standard 10 00 January 2002 ...
Страница 65: ......