![Nortel Meridian 1 Mini-Carrier Remote Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/nortel/meridian-1-mini-carrier-remote/meridian-1-mini-carrier-remote_description-installation-and-maintenance_1706402087.webp)
Installation and configuration
Page 87 of 150
Mini-Carrier Remote
Description, Installation, and Maintenance
ESAM Never
The
ESAM Never
command instructs MCR not to operate in the
Emergency Stand-Alone Mode. Its display is similar to Figure 28.
Figure 28
ESAM Never (E N) screen
Note: This configuration setting can be overridden by the faceplate
ESAM toggle switch.
ESAM Auto
The
ESAM Auto
command instructs MCR to operate in the Emergency
Stand-Alone Mode if all carriers go into a level 2 alarm. Its display is similar
to Figure 28.
Figure 29
ESAM Auto (E A) screen
Note: This configuration setting can be overridden by the faceplate
ESAM toggle switch.
SET [TIME | DATE | ALARM | CONFIG | NAME |
ESAM | SPAN]
The
SET
command configures various properties of the MCR system.
SET TIME (S T)
This command configures the time kept at the near end of the system. Its
display is similar to Figure 30.
MCR::>e n
MCR::>
MCR::>e a
MCR::>