Introduction

This guide shows how to install media dependent adapters 
(MDAs) into supported Nortel Networks products. 

Table 1 lists the available MDA models.

Nortel Networks is constantly adding new models and 
features to existing product lines; for a full range of MDAs 
that are available from Nortel Networks, see your Nortel 
Networks sales representative.

For more details, see your switch product user’s guide.

Table 2 on page 2 lists the supported Nortel Networks 
products.

Table 1.

MDA Models

Interface Type

Model

Refer to:

10/100BASE-TX (UTP)

400-4TX MDA

8100-4TX MDA

page 3

100BASE-FX (Fiber)

400-2FX MDA

8100-2FX MDA

400-4FX MDA 

8100-4FX MDA

page 6

1000BASE-SX
(Shortwave gigabit fiber)

450-1SR MDA

450-1SX MDA

page 12

1000BASE-LX
(Longwave gigabit fiber)

450-1LR MDA

450-1LX MDA 

page 17

302403-C.mkr  Page 1  Monday, May 24, 1999  4:30 PM

Содержание Media Dependent Adapter

Страница 1: ...TM Part No 302403 C Rev 00 June 1999 Installing Media DependentAdapters MDA s ...

Страница 2: ...ent is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy If it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures ma...

Страница 3: ...rom Nortel Networks see your Nortel Networks sales representative For more details see your switch product user s guide Table 2 on page 2 lists the supported Nortel Networks products Table 1 MDA Models Interface Type Model Refer to 10 100BASE TX UTP 400 4TX MDA 8100 4TX MDA page 3 100BASE FX Fiber 400 2FX MDA 8100 2FX MDA 400 4FX MDA 8100 4FX MDA page 6 1000BASE SX Shortwave gigabit fiber 450 1SR ...

Страница 4: ... Yes Yes No 400 4FX MDA Yes Yes No 450 1SR MDA Yes No Yes 450 1SX MDA Yes No Yes 450 1LR MDA Yes No Yes 450 1LX MDA Yes No Yes 8100 4TX MDA Yes Yes Yes 8100 2FX MDA Yes Yes Yes 8100 4FX MDA Yes Yes Yes Note The MDAs are not hot swappable Power down the BayStack switch or disconnect the Accelar module from the switch backplane before installing or removing an MDA ...

Страница 5: ...ASE TX MDAs There are two 10 100BASE TX MDA models Figure 1 Figure 1 10 100BASE TX Models BS45042B 400 4TX MDA Activity 100 10 F Dx 1 4 5 3 2 400 4TX MDA 8100 4TX MDA Activity 100 10 F Dx 1 4 5 3 2 8100 4TX MDA ...

Страница 6: ...MDI X connectors These ports connect over straight cables to the network interface controller NIC card in a node or server similar to a conventional Ethernet repeater hub If you are connecting to another Ethernet hub or Ethernet switch you need a crossover cable unless an MDI connection exists on the associated port of the attached device The 10 100BASE TX MDA ports can operate at either 10 Mb s o...

Страница 7: ...inking The corresponding port is management disabled 2 10 10BASE T port status LEDs green On The corresponding port is set to operate at 10 Mb s Off The link connection is bad or there is no connection to this port Blinking The corresponding port is management disabled 3 F Dx Full duplex port status LEDs green On The corresponding port is in full duplex mode Off The corresponding port is in half d...

Страница 8: ...iber optic equipment can emit laser or infrared light that can injure your eyes Never look into an optical fiber or connector port Always assume that fiber optic cables are connected to a light source Vorsicht Glasfaserkomponenten können Laserlicht bzw Infrarotlicht abstrahlen wodurch Ihre Augen geschädigt werden können Schauen Sie niemals in einen Glasfaser LWL oder ein Anschlußteil Gehen Sie ste...

Страница 9: ...ica pueden emitir radiaciones de láser o infrarrojas que pueden dañar los ojos No mire nunca en el interior de una fibra óptica ni de un puerto de conexión Suponga siempre que los cables de fibra óptica están conectados a una fuente luminosa Avvertenza Le apparecchiature a fibre ottiche emettono raggi laser o infrarossi che possono risultare dannosi per gli occhi Non guardare mai direttamente le f...

Страница 10: ...ptic cable 400 4FX MDA Not supported on the Accelar Series Modules see Table 2 on page 2 8100 4FX MDA Supports BayStack 350 450 BayStack 410 and Accelar Series Modules see Table 2 on page 2 The 400 4FX MDA and the 8100 4FX MDA Figure 3 each use four longwave 1300 nm MT RJ connectors to attach devices over 62 5 125 micron multimode fiber optic cable The 100BASE FX MDA models conform to the IEEE 802...

Страница 11: ...2 100BASE FX MDA Models 1 of 2 BS45071A RX TX 100BASE FX RX TX 100BASE FX Activity Link F Dx 8100 2FX MDA 3 4 2 1 8100 2FX MDA RX TX 100BASE FX RX TX 100BASE FX Activity Link F Dx 400 2FX MDA 3 4 2 1 400 2FX MDA ...

Страница 12: ...igure 3 100BASE FX MDA Models 2 of 2 Table 4 describes the 100BASE FX MDA components and LEDs BS45072A Activity Link F Dx 400 4FX MDA 3 4 2 1 400 4FX MDA Activity Link F Dx 8100 4FX MDA 3 4 2 1 8100 4FX MDA ...

Страница 13: ...port is management disabled 2 F Dx Full duplex port status LEDs green On The corresponding port is in full duplex mode Off The corresponding port is in half duplex mode 3 Activity Port activity LEDs green Blinking Indicates the network activity level for the corresponding port A high level of network activity can cause LEDs to appear to be on continuously 4 100BASE FX port connectors Models 400 2F...

Страница 14: ...oder der Glasfaserstecker an eine Laserlichtquelle angeschlossen ist Avertissement Ceci est un appareil Laser DEL de Classe 1 Cet appareil contient une source lumineuse à rayons laser dangereuse pour les yeux Ne regardez jamais directement une fibre optique ou un port de connexion Agissez toujours comme si le câble de fibres optiques ou le connecteur était relié à une source lumineuse à rayons las...

Страница 15: ...iene una sorgente luminosa a laser che può danneggiare gli occhi Non guardare mai all interno di una port a fibra ottica o di una porta connettore Dare sempre per scontato che il cavo di fibra ottica o il connettore siano collegati ad una sorgente luminosa a laser ...

Страница 16: ...models Figure 4 Figure 4 1000BASE SX MDA Front Panels 1000BASE SX TX RX Phy Link Activity 450 1SX MDA TX RX 1000BASE SX RX 1000BASE SX TX Activity Link Phy Select 450 1SR MDA 3 BS45044A 4 3 4 450 1SR MDA 1 port redundant 450 1SX MDA single port 2 1 2 1 ...

Страница 17: ...o the IEEE 802 3z 1000BASE SX standard and use shortwave 850 nm fiber optic connectors to connect devices over multimode 550 meter fiber optic cable Table 5 describes the 1000BASE SX components and LEDs Table 5 1000BASE SX MDA Description Item Label Description 1 Link Communication link LEDs green On Valid communications link Off The communications link connection is bad or there is no connection ...

Страница 18: ... corresponding Phy port is in backup mode or there is no connection to this port 3 Activity Port activity LEDs green Blinking Indicates network activity level for the corresponding port A high level of network activity can cause LEDs to appear to be on continuously 4 1000BASE X SC port connectors Table 5 1000BASE SX MDA Description Item Label Description ...

Страница 19: ...oder der Glasfaserstecker an eine Laserlichtquelle angeschlossen ist Avertissement Ceci est un appareil Laser DEL de Classe 1 Cet appareil contient une source lumineuse à rayons laser dangereuse pour les yeux Ne regardez jamais directement une fibre optique ou un port de connexion Agissez toujours comme si le câble de fibres optiques ou le connecteur était relié à une source lumineuse à rayons las...

Страница 20: ...iene una sorgente luminosa a laser che può danneggiare gli occhi Non guardare mai all interno di una port a fibra ottica o di una porta connettore Dare sempre per scontato che il cavo di fibra ottica o il connettore siano collegati ad una sorgente luminosa a laser ...

Страница 21: ...MDA models Figure 5 1000BASE LX MDA Front Panels 1000BASE LX TX RX Phy Link Activity 450 1LX MDA BS45045A 3 4 2 1 TX RX 1000BASE LX RX 1000BASE LX TX Activity Link Phy Select 450 1LR MDA 3 4 2 1 450 1LR MDA 1 port redundant 450 1LX MDA single port ...

Страница 22: ...X standard and use longwave 1300 nm fiber optic connectors to connect devices over single mode 3 kilometer or multimode 550 meters fiber optic cable Table 6 describes the 1000BASE LX MDA components and LEDs For installation instructions see Installing an MDA on page 22 Note The optical performance of this transceiver cannot be guaranteed when connected to a multimode fiber plant without the use of...

Страница 23: ...led 2 PHY or Phy Select Phy status LEDs green On The corresponding Phy port is active Off The corresponding Phy port is in backup mode or there is no connection to this port 3 Activity Port activity LEDs green Blinking Indicates network activity level for the corresponding port A high level of network activity can cause LEDs to appear to be on continuously 4 1000BASE X SC port connectors see 1000B...

Страница 24: ...he thumb screws and remove the filler panel or previously installed MDA from the Uplink Module slot 3 Insert the MDA into the Uplink Module card guides Figure 6 Make sure the MDA slides in on the card guides Failure to align the MDA to the card guides could damage the pins Note The MDAs are not hot swappable Power down the BayStack switch or disconnect the Accelar module from the switch backplane ...

Страница 25: ...or 5 Secure the MDA by tightening the thumb screws on the MDA front panel 6 Attach devices to the MDA ports Refer to your device user guide for instructions on attaching devices to the MDA ports BS45059B Uplink Expansion Module 28 26 27 25 3 1 Card guides 2 Uplink module slot 3 BayStack or Accelar switch 2 1 400 4TX MDA Activity 100 10 F Dx ...

Страница 26: ...cord from the power source 2 Remove the installed MDA Loosen the thumbscrews and remove the MDA 3 Cycle the switch power Power up the switch and wait for the Nortel Networks logo screen to appear approximately 20 seconds then power down the switch 4 Install the replacement MDA Be sure to firmly tighten the two thumbscrews on the MDA front panel 5 Power up the switch Note The IEEE 802 3u specificat...

Страница 27: ...fset SMF MMF patch cord Multimode ferrules must not be used because they can bind and cause damage to the transceiver Do not connect multimode cables directly into the 1000BASE LX MDA transceiver Instead connect a special offset SMF MMF patch cord into the transceiver and then connect the multimode cable into the SMF MMF patch cord For more information about gigabit transmission over fiber optic c...