Page 138 of 174
Appendix A: Flash Download procedure
553-3001-216 Standard
5.00
January 2002
with a “FA” designation for U.S. and Canada sets and “EA” for Canada
only icon sets.
Note 2:
For Column 4 labeled
M1 F/W File
, the two-letter alpha
character followed by two numbers (format:
390x.load
xx##) shows the
release level of the PSWV file. For instance, M3902.loadaa40 is a later
issue than M3902.loadaa36. The most up-to-date file names are shown.
Note 3:
For Column 5 labeled LD 22
Response for PSWV
, the two
number code is the firmware version release level. The larger the
number, the newer the version. The last two digits correspond to the same
version number as the M3900 firmware version. For instance, M3903:
S/W VERSION NUMBERS: 51 is equivalent to M3900 F/W Version
5.1. The most current versions are shown.
Note 4:
Column 6, labeled
Set F/W Diagnostic
, shows the language file
in use and the firmware level of the set, as seen on an M3900 display. The
larger the number, the newer the version. The latest versions are shown.
To view the firmware level of an M3900 set, press the Options key, scroll
to the Display Diagnostics entry, and press Select. Use the Down
Navigation key to get to the screen that shows the language file and
firmware version.
Note 5:
For Column 7 labeled
LD 32 FWVU Response for set F/W
, the
three-digit number shows the firmware version of the set. The larger the
number, the newer the version. For example, a number of 040, refers to
a firmware version of 4.0. The latest versions are shown.
Flash Download advisements
•
Since the Flash Downloadingfeature of the M3900 takes some
bandwidth from the system signaling path while it is operating, it is
recommended that downloadingbe scheduled in off-peak hours for best
results. There is some real time impact to the system since the system
processor is busy doingthe downloads. However, there is no impact to
call processing, since call processing has a higher priority. Therefore,
downloads take longer during peak traffic times because the system
processor is busy doingcall processingand cannot devote as much time
to the M3900 downloads. There is no difference between large and small
systems for this.
Содержание M3905
Страница 2: ......
Страница 4: ...Page 4 of 174 553 3001 216 Standard 5 00 January 2002 ...
Страница 12: ...Page 12 of 174 About this document 553 3001 216 Standard 5 00 January 2002 ...
Страница 44: ...Page 44 of 174 Functional description 553 3001 216 Standard 5 00 January 2002 ...
Страница 54: ...Page 54 of 174 Hardware options 553 3001 216 Standard 5 00 January 2002 ...
Страница 86: ...Page 86 of 174 Configure the M3900 Series Meridian Digital Telephone 553 3001 216 Standard 5 00 January 2002 ...
Страница 104: ...Page 104 of 174 Installation 553 3001 216 Standard 5 00 January 2002 ...
Страница 110: ...Page 110 of 174 Environmental and safety considerations 553 3001 216 Standard 5 00 January 2002 ...
Страница 170: ...Page 170 of 174 Appendix A Flash Download procedure 553 3001 216 Standard 5 00 January 2002 ...
Страница 174: ...Page 174 of 174 List of terms 553 3001 216 Standard 5 00 January 2002 ...
Страница 175: ...1 ...