NN10078-911 SN06.2 Preliminary 02.03 March 2004
43
Copyright © 2004, Nortel Networks
Nortel Networks Confidential
11
Determine the state of the module.
12
Replace the module identified in
. When you
complete the card replacement procedure, go to
of this procedure.
13
Access the protection level of the MAP screen by typing
>PROT
and pressing the Enter key.
14
Do a manual protection switch with a module in the same
protection group by typing
>MANUAL <from_unit_no> <to_unit_no>
and pressing the Enter key.
where
from_unit_no
is the number (0 to 27) of the module with the alarm.
to_unit_no
is the number (0 to 27) of the inactive module in the same
protection group
Example of a MAP screen:
15
List the alarms on the module by typing
>LISTALM
and pressing the Enter key.
16
Determine whether the alarm has cleared.
17
For further assistance, contact the personnel responsible for the
next level of support.
If the module is
Do
InSv
in any other state
If the alarm list indicates
Do
PROTFAIL
None
SPM 0 DSP 1 Manual: Request has been submitted.
SPM 0 DSP 0 Manual: Command completed.