Installation and commissioning procedures 6-15
User guide NTXXXXXX Rel 3.0 Draft October 2000
Procedure 6-3 (continued)
Connecting the interface cables
Action
Step
Action
Connect to the customer equipment
1
Connect the twisted-pair wires of the interface cable to the customer
equipment as shown in
(use a twisted-pair for each Tx and Rx
connection.
Table 6-5
Input pin assignments for twisted-pair interface cable
2
Record the wire colors for each pin in the columns in
or label the
wires for easy identification at the DS1/E1 equipment end.
—continued—
Pin
Signal Description
Pin
Signal Description
1
Case Gnd
17
RX Tributary 3 Ring
2
Reserved
18
Summary Alarm relay (NC)
3
TX Tributary 1 Tip
19
TX Tributary 4 Tip
4
TX Tributary 1 Ring
20
TX Tributary 4 Ring
5
RX Tributary 1 Tip
21
RX Tributary 4 Tip
6
RX Tributary 1 Ring
22
RX Tributary 4 Ring
7
RS 485+
23
Alarm relay Common (CC)
8
TX Tributary 2 Tip
24
DC Power Conn#1
9
TX Tributary 2 Ring
25
RS422 RX+
10
RX Tributary 2 Tip
26
RS422 RX-
11
RX Tributary 2 Ring
27
DC Power Conn#2
12
Programmable Alarm Relay
(NC)
28 RS422
TX-
13
RS 485-
29
RS422 TX+
14
TX Tributary 3 Tip
30
DC Power Conn#2
15
TX Tributary 3 Ring
31
DC Power Conn#1
16
RX Tributary 3 Tip
Содержание Internet BWA System 3200
Страница 6: ...vi About this document Internet BWA System 3200 NTXXXXXX Rel 3 0 Draft October 2000 ...
Страница 15: ...Ordering Information 2 3 User guide NTXXXXXX Rel 3 0 Draft October 2000 ...
Страница 16: ...2 4 Ordering Information Internet BWA System 3200 NTXXXXXX Rel 3 0 Draft October 2000 ...
Страница 20: ...3 4 Technical specifications Internet BWA System 3200 NTXXXXXX Rel 3 0 Draft October 2000 ...
Страница 40: ...5 12 User interface description Internet BWA System 3200 NTXXXXXX Rel 3 0 Draft October 2000 ...
Страница 66: ...6 26 Installation and commissioning procedures Internet BWA System 3200 NTXXXXXX Rel 3 0 Draft October 2000 ...
Страница 67: ......