16 of 24    Release Notes

INM Broadband Release 3.1

Issue 1.0

login is implemented for MOA based Controllers (as opposed to OPCs).
The user could potentially open any number of login sessions consuming
more and more resources and ultimately affecting performance of other
functionality. The user has to take note of this limitation and ensure to keep
the number of open sessions per GNB session, at any time to 6.

 9. Fault Management

1

The OPC collects OPC alarms all the time. Turning the pointer alarm on
triggers the NE to raise the corresponding Pointer Alarm. The Pointer
Alarm is a “pointer to the OPC alarm monitor which contains actual OPC
alarms”. The OPC alarms are still shown even though the Pointer Alarm is
de-provisioned.

 10. Connection Management

1

When the user selects the Edit command from the nodal object menu in the
middle of building an end-to-end connection for the OC3 Express, there is
no dialog presented to confirm if the user wants to abandon the NE
navigation mode. Therefore, if the user selects the Edit command from the
nodal object menu, he is placed into an Edit connection mode right away.

2

When editing an STS-3c connection on an OC-12 TBM MUX system, the
user will always get a failure message indicating that the data could not be
applied to the NE.  This error message can be misleading if the edit was
actually successful. There is no workaround for this problem. The user
should use the audit facilities to check if the edit was successful.

3

When 2 Connection Management windows (from 2 GNBs) are opened for
the same OC-3 Express NE and if connections are modified from the craft
interface simultaneously, the connection changes made at the craft
interface are not captured in the Connection Management inventory
displays. Both Connection Management windows have to be closed and
re-opened in order to see the connections. The OC-3 Express Network
Element does not provide an automatic change notification.

4

While in-service roll over is being performed at the OPC the channels
involved in the roll over (i.e the ones that are being rolled over from and
the ones being rolled over to) should be marked used in both directions in
the INM Channel Usage dialog.  At the moment for the Bridge and Switch
stages of the in-service roll over only one direction is marked used. The
user may be misled into thinking the channels are available for uni
directional connections when in fact they are not.  If the user then tries to
provision the connection, then the OPC will reject it. The dialog that comes
up does not tell him the reason for rejecting this connection.

 11. Remote Inventory and Shelf Level Graphics

1

When the Query inventory dialog is opened and the user wants to select
individual NEs from the “confine search to” area and if there is a large
number of NEs in the span so that he has to scroll down the NE list, then
if the user checks or unchecks any of the NEs except the first one, the

Содержание INM 3.1

Страница 1: ...Release Notes NTse68aA 0100 Integrated Network Management Products INM Broadband Release Notes For Release 3 1 Document release issue 1 0 Date November 1997...

Страница 2: ......

Страница 3: ...is a trademark of Network Computing Devices S DMS AccessNode is a trademark of Northern Telecom S DMS TransportNode is a trademark of Northern Telecom Tektronix is a trademark of Tektronix Corporation...

Страница 4: ...Publication history November 20 1997 1 0 Jacques Kuftedjian Official Release for RTM November 20 1997 0 2 Draft Jacques Kuftedjian Release for review only October 10 1997 0 1 Draft Jacques Kuftedjian...

Страница 5: ...Release Notes 13 1 Installation 13 Upgrades 13 New Installs 13 2 Federated Networks 13 3 Problem Analyzer 14 4 Partitioned Access 14 5 Alarm History 15 6 Improved On Line Help 15 7 Bridging 15 8 MOAs...

Страница 6: ...vi of 24 Table of Contents INM Broadband Release 3 1 Issue 1 0...

Страница 7: ...read all relevant User Guides prior to installing and using the product Structure of the document This document is structured in a way to highlight the operational considerations for each of the feat...

Страница 8: ...8 of 24 About this document INM Broadband Release 3 1 Issue 1 0...

Страница 9: ...network and which can be configured to permit some or all management functions to be enabled for the user Problem Analyzer PA performs Intelligent Alarm Filtering IAF which provides the correlation of...

Страница 10: ...witched connections and Drop and Continue and Broadcast Remote Inventory Shelf Level Graphics and Performance Monitoring are supported with functionalities similar to that provided for other types of...

Страница 11: ...for access to the GNE is able to initiate bridging to any controller in the network which supports bridging This includes those controllers not directly connected to the specific INM workstation Pack...

Страница 12: ...12 of 24 Summary of Features INM Broadband Release 3 1 Issue 1 0...

Страница 13: ...base procedure in the INM Broadband GUI User Guide Upgrade the HP UX operating system to 10 10 or 10 20 Install INM Broadband 3 1 software using the Installing the INM Broadband GUI software procedure...

Страница 14: ...twork elements have still been successfully added to the window It is just that they are not visible after being added like they normally are because the scroll bar is not positioned at the very botto...

Страница 15: ...The colors of the links that are displayed in the Netscape main window legend of icons for example do not correspond to the colors that are displayed in the GNB For example a turquoise link active lin...

Страница 16: ...no workaround for this problem The user should use the audit facilities to check if the edit was successful 3 When 2 Connection Management windows from 2 GNBs are opened for the same OC 3 Express NE...

Страница 17: ...e Notes Issue 1 0 whole NE list shifts to the right Therefore if the user wants to check or uncheck specific NEs he has to scroll to the left to check or uncheck the next NE This can be annoying to th...

Страница 18: ...18 of 24 Release Notes INM Broadband Release 3 1 Issue 1 0...

Страница 19: ...ive Committee on International Telegraphy and Telephony CLFI Common Language Facility Identifier CMT Character Mode Terminal CPC Corporate Product Code CPG Circuit Pack Group CSMA CD Carrier Sense Mul...

Страница 20: ...and Provisioning OS Operating system OC 3 Optical Signal Carrier Level 3 155 520M bps OC 12 Optical Signal Carrier Level 12 622 080 M bps OC 48 Optical Signal Carrier level 48 2 488 G bps OPC OPerati...

Страница 21: ...thern Telecom Inc 5555 Windward Parkway West Building B Alpharetta Georgia 30201 404 661 4050 Northeast Region Northern Telecom Inc 200 Summit Lake Drive Valhalla New York 10595 914 773 2559 Central R...

Страница 22: ...0 FSE West Saskatchewan Northern Telecom Canada Limited PO Box 770 Regina Saskatchewan S4P 3A8 306 791 7110 Ontario Northern Telecom Canada Limited P O Box 3000 Brampton Ontario L6V 2M6 905 452 4181 o...

Страница 23: ......

Страница 24: ...k Management Products Integrated Network Management Broadband Release 3 1 Release Notes 1997 Northern Telecom All rights reserved Information subject to change without notice Issue 1 0 November 1997 P...

Отзывы: