Carrier Remote IPE fault isolation and correction
163
Procedure 37
Checking the Local Carrier Interface card status
Step
Action
1
Log in on the maintenance terminal as described in
system maintenance programs” (page 154)
2
At the > prompt, type
LD 32
and press the Enter key to access
the Maintenance and Diagnostic Program LD 32.
3
Type
STAT sl
and press the Enter key, where
sl
is the
superloop number.
It shows the highest alarm value of both cards being checked.
The far-end alarm does not show at the near end.
LD 32
NPR000
STAT sl
CARR
CALS
TTSA
NND
SPARED
0
0
21/21
NO
N/A
1
0
21/21
NO
N/A
2
0
21/21
NO
N/A
Note: This example shows 3 primary carriers and no spare, all
carriers without alarm, and are available for New Data Calls. No calls
in progress.
LD 32
NPR000
STAT sl
CARR
CALS
TTSA
NND
SPARED
0
3
0/21
YES
N/A
1
0
21/21
NO
N/A
2
0
21/21
NO
N/A
Note: This example shows 3 primary carriers and no spare, carrier 0
in los-of-signal (LOS) fault status.
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01
4 June 2010