![Nortel CallPilot 5.0 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/nortel/callpilot-5-0/callpilot-5-0_quick-start-manual_1707182013.webp)
13
CS 1000/M1 system status check
This task describes how to check the Communication Server 1000 (CS
1000) or the Meridian 1 (M1) system status.
To successfully install a basic CallPilot system, you must provision or verify
the following parameters on the telephony switch (CS 1000 or M1):
•
PBX IP and host name
•
VAS ID
•
ELAN ID
•
system parameters
•
ACD
•
DFDN
•
CDN
•
ACD agents
•
telephones
CallPilot can be provided only on a per-customer basis on the CS 1000
or M1 system. ELAN messages used for communication between the
telephony switch and CallPilot contain a customer number to which CallPilot
belongs. In these procedures, ensure that you enter the correct customer
number in the overlays.
CS 1000/M1 system status check tasks
The following is a list of tasks you perform to check the status of the CS 1000
or M1 system. To link to detailed procedures for each task, click the text.
•
"Checking the current IP address of the PBX (LD 117)" (page 14)
•
"Checking the currently configured VAS IDs" (page 14)
•
"Checking the ELAN interface status of the PBX (LD 137)" (page 15)
•
"Enabling the ELAN interface of the PBX (LD 137)" (page 15)