Performing RAID maintenance
Standard 1.0
186
CallPilot
RAID EzAssist utility
To configure the AcceleRAID controller, regardless of whether an operating
system is installed on your computer, the RAID EzAssist utility can be run
from the Mylex controller’s BIOS at any system boot time.
To enter the EzAssist utility and configure the RAID, follow the instructions
in “To configure RAID using Mylex AcceleRAID 352” below.
To configure RAID using Mylex AcceleRAID 352
Newer Mylex RAID cards have an option that you must set before you
configure them. Complete the following steps to properly configure your
RAID card.
1
Power on the system.
Result:
The AR352 messages appear.
2
When the message
Press Alt-M for BIOS options
appears,
press Alt+M simultaneously.
Result:
The AR352 BIOS options appear.
3
Use the arrow keys to move to the 2 GB Drive Geometry option, and then
press Enter.
Result:
The system prompts you to use 8 GB Drive Geometry and to
confirm the change.
Note:
Your controller may already be configured as 8 GB Drive
Geometry. If it is already configured, press Esc to exit and restart.
4
Confirm the change, and then press Esc to escape this menu.
Содержание CallPilot 1001rp
Страница 2: ...P0949455...
Страница 6: ...vi CallPilot Publication history Standard 1 0...
Страница 38: ...Troubleshooting your CallPilot system Standard 1 0 38 CallPilot...
Страница 62: ...Using Windows NT online diagnostic tools Standard 1 0 62 CallPilot...
Страница 74: ...Using serial port diagnostic tools Standard 1 0 74 CallPilot...
Страница 88: ...Using CallPilot Manager to monitor hardware Standard 1 0 88 CallPilot...
Страница 114: ...Using CallPilot Manager to monitor hardware Standard 1 0 114 CallPilot...
Страница 150: ...Replacing basic chassis components Standard 1 0 150 CallPilot...
Страница 168: ...Replacing a hard drive tape drive CD ROM drive or floppy drive Standard 1 0 168 CallPilot...
Страница 178: ...Performing RAID maintenance Standard 1 0 178 CallPilot...
Страница 260: ...Performing RAID maintenance Standard 1 0 260 CallPilot...
Страница 274: ...Replacing or adding voice processing boards Standard 1 0 274 CallPilot...
Страница 280: ...Replacing the video card Standard 1 0 280 CallPilot...
Страница 292: ...Replacing the network cards Standard 1 0 292 CallPilot...
Страница 320: ...Maintaining the Pentium II SBC card Standard 1 0 320 CallPilot Pentium II SBC...
Страница 326: ...Maintaining the Pentium II SBC card Standard 1 0 326 CallPilot 22 Reconnect the serial port cables EMI gasket...
Страница 348: ...Maintaining the Pentium III SBC card Standard 1 0 348 CallPilot...
Страница 367: ......