Conti vit y 251 ABOT D eployment
Version 1. 0
April 26, 2004
3.6 Configure Contivity Gateway 1100
Figure 7: Configure C1100 from Factory Default
3.6.1 Configure IP address & DHCP for C1100:
1: Reset C1100 to Factory Default (V04_80.124)
Connect PC S3 to C1100 (both Ethernet and serial port), and open a Hyper terminal. In
“Main Menu”, select “R” to reset the C1100 to be factory default.
2: configure IP addresses for management and priv ate interface
(address and mask are determined during the phase of Netw ork planning)
Slot 0, Port 1, Private LAN
Management IP Address =
192.168.3.2
, ( Subnet Mask = 255.255.255.0 )
Interface IP Address =
192.168.3.1
Subnet Mask =
255.255.255.0
3: Configure public interface (must obtain IP address and mask from ISP)
Slot 1, Port 1, Public LAN
IP Address =
24.1.61.69
Subnet Mask =
255.255.240.0
Speed/Duplex = AutoNegotiate
CO
NOC
S3
192.168.3.9
Dynamic IP
V04_80.124
C1100 gateway
192.168.3.1 priv-if
192.168.3.2 mgt
DHCP server
192.168.3.0/24
ABOT responder
Ip-pool: 172.16.55.1-10