Chapter 4 Installing the analog terminal adapter
27
Telephony Device Installation Guide
To measure the insertion loss from the analog device to the CO
1
Establish a connection to a silent termination on the CO service line with an analog telephone
attached to the ATA2.
2
Make sure the analog port terminates correctly in 600 ohms:
•
Replace the analog telephone with the test set.
•
Use TRANSMIT/600 OHM/HOLD mode on the test set.
3
Make sure the test set connects in parallel to the service line before removing the analog
telephone or the line drops.
4
Remove the analog telephone.
5
Introduce a 1-kHz tone into the analog line at - 10 dBm, and measure the level at the CO
exchange.
Configuring the ATA2
Configure the ATA2 using Element Manager or Telset Administration. For detailed configuration
information, refer to the
BCM50 Device Configuration Guide
(N0027146)
.
Note:
The difference in levels is the transmit loss and must be less than 10 dB
(for example, 9 dB is acceptable).
Содержание BCM50 2.0
Страница 6: ...6 Contents NN40020 309 NN40020 309...
Страница 18: ...18 Chapter 2 Device description NN40020 309 NN40020 309...
Страница 28: ...28 Chapter 4 Installing the analog terminal adapter NN40020 309 NN40020 309...
Страница 57: ...Chapter 7 Registering Nortel 20XX and 11XX IP telephones 57 Telephony Device Installation Guide...
Страница 58: ...58 Chapter 7 Registering Nortel 20XX and 11XX IP telephones NN40020 309 NN40020 309...
Страница 62: ...62 Chapter 8 Relocating telephones NN40020 309 NN40020 309...
Страница 64: ...64 Appendix A ADID wiring chart NN40020 309 NN40020 309...
Страница 70: ...70 Appendix D DTM wiring chart NN40020 309 NN40020 309...
Страница 82: ...82 Appendix H GATM wiring chart NN40020 309 NN40020 309...