Chapter 4 Installing the analog terminal adapter
NN40020-309
NN40020-309
Figure 7
Insertion loss from the CO to the analog telephone
Measure the total insertion loss between the CO and analog device by using standard dial-up test
lines with a transmission test set (for example, Hewlett-Packard 4935A Transmission Test Set).
To measure the insertion loss from the CO to the analog device
1
Establish a connection to the 1 mW, 1 kHz, CO service line with an analog telephone attached
to the ATA2.
2
Ensure that the analog port terminates correctly in 600 ohms:
•
Replace the analog telephone with the test set.
•
Use RECEIVE/600 OHM/HOLD mode on the test set.
3
Ensure that the test set connects in parallel to the service line before removing the analog
telephone, or the line drops.
4
Remove the single-line telephone.
5
Measure the 1-kHz tone at the far end of the analog port, which is where the analog loop ends
and where the analog device connects.
Longitudinal balance to ground
50 dB
60 to 4,000 Hz
With IEEE 455-1976 test
Overload level
3 dB
Note:
The tone must be greater than - 10 dB (for example, - 9 dB is acceptable).
Содержание BCM50 2.0
Страница 6: ...6 Contents NN40020 309 NN40020 309...
Страница 18: ...18 Chapter 2 Device description NN40020 309 NN40020 309...
Страница 28: ...28 Chapter 4 Installing the analog terminal adapter NN40020 309 NN40020 309...
Страница 57: ...Chapter 7 Registering Nortel 20XX and 11XX IP telephones 57 Telephony Device Installation Guide...
Страница 58: ...58 Chapter 7 Registering Nortel 20XX and 11XX IP telephones NN40020 309 NN40020 309...
Страница 62: ...62 Chapter 8 Relocating telephones NN40020 309 NN40020 309...
Страница 64: ...64 Appendix A ADID wiring chart NN40020 309 NN40020 309...
Страница 70: ...70 Appendix D DTM wiring chart NN40020 309 NN40020 309...
Страница 82: ...82 Appendix H GATM wiring chart NN40020 309 NN40020 309...