background image

7

Shared VLAN (SVL) and individual VLAN (IVL) learning are supported. With SVL
support, all VLANs in the switch share the same forwarding database. IVL allows indi-
vidual VLANs to have separate forwarding databases within the switch, and it allows the
switch to handle duplicate MAC addresses if the addresses are in different VLANs. 

IGMP snooping 

The BayStack 460 Switch features IP Multicast support by examining (‘snooping’) all
Internet Group Multicast Protocol (IGMP) traffic in hardware at line rate, and filtering
out (dropping) unwanted IGMP packets such as PING from disrupting network or end-
station performance. 

Multiple spanning tree protocol groups 

The BayStack 460 Switch supports multiple Spanning Tree Groups (STGs). It supports a
maximum of eight STGs, either all in one standalone switch or across a stack consisting
solely of BayStack 460 Switches. Multiple STGs provide multiple data paths, which can
be used for load balancing and redundancy. 

Command Line Interface (CLI)

The CLI is used to automate general management and configuration of BayStack 460
Switches. The CLI is used through a Telnet session or through the serial port on the console.

ASCII configuration file 

The BayStack 460 Switch can download a user-editable ASCII configuration file from a
Trivial File Transfer Protocol (TFTP) server. The ASCII configuration file can be loaded
automatically at boot time or on demand using the management systems (console menus
or CLI). Once downloaded, the configu-
ration file automatically configures the
switch or stack according to the CLI
commands in the file. This feature allows
the flexibility of creating command
configuration files that can be used on
several switches or stacks with minor
modifications. 

Supports Spanning Tree
Protocol 

Built-in support for Spanning Tree
Protocol (IEEE 802.1D) detects and elim-
inates logical loops in the network. When
multiple paths exist, the switch will auto-
matically place some ports on standby to
form a network with the most efficient
traffic pathways, avoiding the continual
looping of frames.

Port mirroring 

The port mirroring feature (sometimes referred to as ‘conversation steering’) allows the
network administrator to designate a single switch port as a traffic monitor for a specified
port. Port mirroring copies packets flowing into a specified port and sends the replicated
data to the mirrored port for in-depth analysis of switched traffic patterns to troubleshoot
problems and optimize network configurations. Additionally, an external probe device can
be attached to the designated monitor port.

Business Communications

Manager

BayStack 460 Stack

Business Series

Terminals

Servers

Desktop

users

WLAN

Access Point

2220

i2004

Standard LAN

Power over Ethernet

Power

10/100

Mbps

Net

camera

Figure 5. Small to medium enterprise solution 

Содержание BayStack 460-24T-PWR

Страница 1: ... be transmitted over a single cable without using power outlets Flexible stacking across different BayStack switches a stack is managed as a single entity with a single IP address Simple software upgrades with single image for different switches Network availability with QoS features Fail safe stacking design assures continuous uptime Resilient connectivity for minimal network downtime Secure acce...

Страница 2: ... BayStack 460 Switch is equipped with autosensing technology to automatically detect and support the speed and mode of a connected device The ports determine whether a connected device is operating at 10 Mbps or 100 Mbps and auto matically adjust to the optimal speed Each of the switched ports also automatically detect and support full duplex connections to servers power user end stations or other...

Страница 3: ...s Policy Switch BayStack 470 48T and BayStack 470 24T BoSS simplifies network opera tions and provides the flexibility of stacking different switches in the same stack Simplified network operations BoSS simplifies network operations by reducing the number of steps required for switch software updates With BoSS you need to download only a single image from Nortel Networks for four different switch ...

Страница 4: ...or SNMP Unit replacement feature In the unlikely event that a switch fails in a stack the affected switch can easily be replaced without disrupting the stack This feature provides the capability of upgrading a new unit with the configuration of the affected unit off line before adding the new unit to the stack The configuration of the affected switch may be copied from the Trivial File Transfer Pr...

Страница 5: ... to copy internal system log messages onto a remote Syslog server Lastly the Show Logging feature gives the administrator flexibility to view and sort the login entries in forward or reverse manner Fail safe stacking and resiliency A key differentiation for the BayStack 460 Switch is its resilient stacking feature The BayStack 460 Switch can stack up to eight units with a cascade stacking design a...

Страница 6: ...ssion 1000 Business Communications Manager Meridian and BayStack all provide the choices that allow enterprises from small and medium businesses to large campus infrastructures to deploy the solution that is right for them and offers the flexibility to implement infrastructure changes at their own pace Figure 5 depicts an example of a small to mid sized enterprise solution with the BayStack 460 Sw...

Страница 7: ...P server The ASCII configuration file can be loaded automatically at boot time or on demand using the management systems console menus or CLI Once downloaded the configu ration file automatically configures the switch or stack according to the CLI commands in the file This feature allows the flexibility of creating command configuration files that can be used on several switches or stacks with min...

Страница 8: ...abase is maintained on the authentication server not the switch EAP prevents network connectivity without password authorization for added security and control in physically non secure areas It is used where the network is not 100 percent physically secure or where physical security needs enhancement for example banks trading rooms or classroom training facilities EAP supports client access to the...

Страница 9: ...er can be supplied to devices in case the power supply of the BayStack 460 fails Uninterruptible power supply support Using a BayStack 10 PSU will provide up to 75 watts of power to be supplied to devices in case there is an electrical outage Up to 15 minutes of battery life is provided this will vary depending on the amount of modules installed on the BayStack 10 Using an NES DC power system up t...

Страница 10: ...vents on BayStack 460 Switches Tools such as Physical Topology View inform the network manager how a particular event is affecting the physical connectivity within the network The End Node Locate tool provides the ability to locate a failing end node and with one mouse click have access to the RMON statistics for the failing Ethernet port supporting that end node These solutions provide visual and...

Страница 11: ... Switch s built in Web based management tools to facilitate QoS or alternatively Optivity Policy Services can be utilized for dynamic end to end enterprise wide policy and QoS management facilitated through the Common Open Policy Service COPS protocol Quality of Service provisioning With Optivity Policy Services policies can be created through a simple and intuitive drag and drop workflow Optivity...

Страница 12: ...ts of traffic can be supported across one single mode fiber There are eight different wavelength GBIC options for 40 km and eight different wavelength GBIC options for 70 km Traffic Policing Traffic Policing enables provisioning of different levels of service by limiting traffic throughput at the ingress incoming port of the BayStack 460 Switch For example if a port is set to certain speeds such a...

Страница 13: ...vices over multimode 550 m or 1 805 ft fiber optic cable 1000BASE LX Uses longwave 1 300 nm fiber optic connectors to connect devices over single mode 5 km or 3 1 mi or multimode 550 m or 1 805 ft fiber optic cable 1000BASE XD Uses single mode fiber to connect devices over distances up to 40 km or 31 mi depending on the quality of the cable 1000BASE ZX Uses single mode fiber to connect devices ove...

Страница 14: ...ximum relative humidity non condensing Operating altitude Up to 3024 m 10 000 ft Storage altitude Up to 3024 m 10 000 ft Safety agency approvals UL listed UL 60950 CUL CAN CSA 22 2 No 60950 CB certificate and report with all national deviations IEC 60950 EN60950 Electromagnetic emissions summary Meets the following standards United States FCC CFR47 PART 15 SUBPART B Class A Canada ICES 003 ISSUE 3...

Страница 15: ...nnector AA1419030 1 port 1000BASE CWDM Small Form Factor GBIC 1570nm Wavelength 40km LC connector AA1419031 1 port 1000BASE CWDM Small Form Factor GBIC 1590nm Wavelength 40km LC connector AA1419032 1 port 1000BASE CWDM Small Form Factor GBIC 1610nm Wavelength 40km LC connector AA1419033 1 port 1000BASE CWDM Small Form Factor GBIC 1470nm Wavelength 70km LC connector AA1419034 1 port 1000BASE CWDM S...

Страница 16: ...hnology and infrastructure to enable value added IP data voice and multimedia services spanning Wireless Networks Wireline Networks Enterprise Networks and Optical Networks As a global company Nortel Networks does business in more than 150 countries More information about Nortel Networks can be found on the Web at www nortelnetworks com For more information contact your Nortel Networks representat...

Отзывы: